1.Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures.
Yi GAO ; Xiaomeng REN ; Chuyang ZENG ; Longbo DU ; Meng LI ; Rui MA ; Wei ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):655-661
OBJECTIVE:
To evaluate the effectiveness of Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures.
METHODS:
A retrospective analysis was conducted on 20 patients with bone defects complicating distal radius fractures who met the selection criteria and were treated between June 2022 and June 2024. The cohort comprised 2 males and 18 females, aged 54-87 years (mean, 63.3 years). Etiologies included falls in 17 cases, traffic accidents in 2 cases, and crush injury in 1 case. According to AO classification, there were 5 cases of type A, 8 cases of type B, and 7 cases of type C. The interval from injury to operation ranged from 2 to 10 days (mean, 5.8 days). All patients underwent volar plate fixation augmented with Poster Fusion Cage and demineralized xenogeneic bone matrix grafting. The operation time, intraoperative blood loss, fracture healing time, and postoperative complications were recorded. Radiographic parameters, including radial height, volar tilt, and ulnar deviation, were measured on standardized X-ray films obtained immediately postoperatively and at last follow-up, and whether secondary reduction loss occurred was judged. At last follow-up, wrist range of motion (extension, flexion, radial deviation, ulnar deviation, pronation, and supination) and grip strength (expressed as a percentage of the contralateral side) were measured. Wrist function was assessed using the Disabilities of the Arm, Shoulder, and Hand (DASH) score and Patient-Rated Wrist Evaluation (PRWE) score.
RESULTS:
The operation time was 70-200 minutes (mean, 116.4 minutes), and the intraoperative blood loss was 10-80 mL (mean, 36.5 mL). All surgical incisions healed by first intention, with no neurovascular complications documented. All patients were followed up 9-12 months (mean, 11.6 months). All fractures healed normally, with a healing time of 8-14 weeks (mean, 9.95 weeks). No significant difference was observed in radial height, volar tilt, or ulnar deviation between immediate postoperatively and last follow-up ( P>0.05). All fractures achieved satisfactory reduction, with no secondary loss of reduction or implant failure occurring during follow-up. At last follow-up, the range of motion of the affected wrist joint was 60°-65° (mean, 62.5°) in extension, 67°-75° (mean, 71.1°) in flexion, 18°-23° (mean, 20.4°) in radial deviation, 28°-33° (mean, 30.1°) in ulnar deviation, 69°-80° (mean, 74.7°) in pronation, and 69°-82° (mean, 75.6°) in supination. Grip strength recovered to 75%-85% (mean, 80%) of the contralateral side. Functional scores showed a DASH score of 5-15 (mean, 9.4) and PRWE score of 8.0-12.5 (mean, 10.2).
CONCLUSION
The combination of Poster Fusion Cage and xenogeneic bone graft augmentation provides a safe and effective treatment for bone defects in distal radius fractures.
Retrospective Studies
;
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Treatment Outcome
;
Wrist Fractures/surgery*
;
Heterografts
;
Transplantation, Heterologous/methods*
;
Bone Transplantation/methods*
;
Operative Time
;
Blood Loss, Surgical
;
Radius/surgery*
;
Fracture Healing
;
Time Factors
;
Postoperative Complications/etiology*
;
Range of Motion, Articular
;
Follow-Up Studies
;
Internal Fixators
;
Fracture Fixation, Internal/methods*
;
Combined Modality Therapy
2.Effectiveness analysis of tension band-assisted fixation for volar marginal fractures of distal radius.
Abulimiti MIREADELI ; Wanming QU ; Tianbo ZHU ; Daoxin ZHANG ; Xiaokang ZHU ; Xinzhi LI ; Wenyao CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):662-667
OBJECTIVE:
To investigate the surgical technique and effectiveness of tension band-assisted plate fixation combined with external fixator for volar marginal fractures of the distal radius.
METHODS:
A retrospective analysis was performed on the clinical data of 12 patients with volar marginal fractures of the distal radius treated by Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator between October 2018 and July 2023. The cohort included 9 males and 3 females, aged from 20 to 52 years (mean, 35.5 years). The injury causes included traffic accidents in 6 cases, falls from height in 3 cases, and fall in 3 cases. According to AO/Orthopaedic Trauma Association (AO/OTA), there were 1 case of type B2, 4 cases of type B3, 2 cases of type C1, 3 cases of type C2, and 2 cases of type C3. According to Fernandez classification, there were 2 cases of type Ⅲ, 5 cases of type Ⅳ, and 5 cases of type Ⅴ. Associated injuries included radiocarpal joint dislocation or subluxation in 7 cases and median nerve injury in 2 cases. The time from injury to operation was 2-7 days (mean, 3.2 days). Postoperatively, functional outcomes were evaluated using the modified Mayo wrist score and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire. Grip strength was measured as the ratio to the unaffected side, and wrist range of motion (ROM) including dorsiflexion, palmar flexion, ulnar deviation, and radial deviation was assessed.
RESULTS:
All procedures were successfully completed, with an operation time of 55-110 minutes (mean, 65 minutes). All patients were followed up 6-36 months (mean, 13.7 months). Surgical incisions healed by first intention, without complications such as vascular-nerve injury or infection. Bony union and articular congruency were attained in all patients, with a healing time of 3-5 months (mean, 3.8 months). During follow-up, 1 case of Kirschner wire migration occurred with no instances of infections, radiocarpal dislocations, internal fixation failures, or extensor pollicis longus tendon ruptures. At last follow-up, the modified Mayo wrist score ranged from 65 to 92 (mean, 80.8), the DASH score ranged from 7 to 15 (mean, 11.6), the grip strength was 65%-90% (mean, 78.2%) of the unaffected side; and wrist ROM was palmar flexion 60°-85° (mean, 77.4°), dorsiflexion 55°-80° (mean, 74.8°), radial deviation 10°-25° (mean, 18.8°), and ulnar deviation 15°-30° (mean, 24.5°).
CONCLUSION
Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator for volar marginal fractures of the distal radius is a simple method with reliable fixation, which can achieve satisfactory effectiveness.
Humans
;
Male
;
Adult
;
Female
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Middle Aged
;
Bone Plates
;
Bone Wires
;
External Fixators
;
Young Adult
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Range of Motion, Articular
;
Hand Strength
;
Wrist Injuries/surgery*
3.Antegrade elastic intramedullary nailing fixation via a novel approach through proximal radius for distal radius metaphyseal-diaphyseal junction fractures in children.
Bin JIN ; Xinglei SHI ; Hailong MA ; Junchen ZHU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1155-1159
OBJECTIVE:
To investigate the surgical technique and preliminary effectiveness of closed reduction and internal fixation (CRIF) using antegrade elastic intramedullary nailing (ESIN) via a novel approach through the proximal radius for treating distal radius metaphyseal-diaphyseal junction (DRMDJ) fractures in children.
METHODS:
A retrospective analysis was conducted on 34 children with DRMDJ fractures who met the selection criteria and were treated between January 2020 and June 2023. There were 21 boys and 13 girls, aged 6-14 years (mean, 8.2 years). Injury causes included falls in 11 cases and sports-related trauma in 23 cases. Twenty-six cases were associated with ipsilateral distal ulnar fractures. All patients had failed initial closed reduction in the outpatient clinic. The time from injury to operation ranged from 1 to 15 days (mean, 4 days). All patients underwent CRIF using antegrade ESIN inserted via a novel approach at the proximal one-third of the radius. The operation time, intraoperative fluoroscopy frequency, fracture healing time, and complications were recorded. Fracture reduction was assessed immediately after operation on anteroposterior and lateral X-ray films for residual translation and angulation. Wrist function was evaluated using the modified Mayo wrist score.
RESULTS:
Surgery was successfully completed in all 34 children. CRIF with ESIN failed in 2 cases with associated ipsilateral distal ulnar fractures, requiring conversion to open reduction of the ulna. Operation time ranged from 15 to 56 minutes (mean, 21 minutes). Intraoperative fluoroscopy frequency ranged from 5 to 21 times (mean, 7 times). Immediate postoperative X-ray films showed residual translation of 0-15% on anteroposterior view and 0-10% on lateral view, and residual angulation of 0°-5° on both anteroposterior and lateral views. All children were followed up 6-18 months (mean, 12 months). There was no complication such as neurovascular injury, incision infection, or limitation of forearm rotation. Follow-up X-ray films showed no fracture displacement, implant loosening, delayed union, or nonunion. Fracture healing time ranged from 4 to 8 weeks (mean, 6 weeks). Implants were removed at 4-6 months postoperatively (mean, 5 months). At last follow-up, all fractures had achieved anatomic or near-anatomic healing. The modified Mayo wrist score ranged from 80 to 100 (mean, 94), with 27 excellent and 7 good results, yielding an excellent and good rate of 100%.
CONCLUSION
CRIF using antegrade ESIN via a novel approach through proximal radius is a safe and effective treatment for pediatric DRMDJ fractures, associated with few postoperative complications and excellent restoration of wrist function.
Humans
;
Child
;
Female
;
Male
;
Fracture Fixation, Intramedullary/instrumentation*
;
Adolescent
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Bone Nails
;
Treatment Outcome
;
Fracture Healing
;
Diaphyses/surgery*
;
Radius/surgery*
;
Operative Time
;
Closed Fracture Reduction/methods*
;
Ulna Fractures/surgery*
4.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
5.Short-term clinical efficacy of unilateral external fixator combined with percutaneous Kirschner wire fixation in the treatment of type C1 distal radius fractures in elderly patients.
Run-Bin SHEN ; Guo-Liang LI ; Xiao-Ping LIU ; Kang CHEN ; Guang-Pu HAN ; Jian-Yong ZHAO
China Journal of Orthopaedics and Traumatology 2025;38(1):25-30
OBJECTIVE:
To investigate the short-term clinical effect of closed reduction single arm external fixator combined with percutaneous needle fixation in the treatment of C1 distal radius fracture in elderly patients.
METHODS:
Between December 2022 and December 2023, a total of 60 elderly patients diagnosed with type C1 distal radius fractures were treated, comprising 9 males and 51 females. The age ranged from 65 to 84 years old, with an average of (72.69±8.14) years old. Among them, there were 18 cases on the left side and 42 cases on the right side. There were 55 cases of falling injury and 5 cases of traffic accident injury. According to the different surgical methods, the patients were divided into observation group and control group, with 30 cases in each group. The control group underwent manual reduction and unilateral external fixator fixation, consisting of 4 males and 26 females. The mean age was (72.54±8.67) years old. The body mass index (BMI) was (20.61±2.17) kg·m-2. There were 10 cases on the left side and 20 cases on the right side. Among them, there were 27 cases of falling injury and 3 cases of traffic accident injury. The observation group was treated with manual reduction and unilateral external fixator combined with percutaneous Kirschner wire fixation, including 5 males and 25 females. The mean age was (72.76±7.23) years old. BMI (20.82±2.03) kg·m-2. The left side was involved in 8 cases and the right side in 22 cases. There were 28 cases of falling injury and 2 cases of traffic accident injury. The changes in radial height, ulnar declination, palmar inclination angle parameters and patient-rated wrist evaluation (PRWE) were assessed on X-ray films before surgery, 2 days after surgery, and 12 weeks after surgery between the two groups.
RESULTS:
All surgical procedures were successfully completed in both groups without any significant complications. All patients were followed up for a duration from 12 to 20 weeks with an average of(14.50±2.78) weeks. The two groups exhibited significant differences in radial height, palmar inclination angle, and ulnar deviation angle at 2 days and 12 weeks post-operation (P<0.05). However, there was no statistically significant difference observed in radial height, palmar inclination, and ulnar deviation between the two groups at 2 days after the operation (P>0.05). There were significant differences in radial height, palmar inclination angle, and ulnar deviation between the two groups at 12 weeks after operation (P<0.05). At 2 days and 12 weeks after the operation, there were significant differences in PRWE scores of the two groups compared with preoperative scores(P<0.05). At 2 days after the operation, there was no significant difference in PRWE score between the two groups (P>0.05). The PRWE score showed a significant difference between the two groups at 12 weeks post-operation(P<0.05).
CONCLUSION
The combination of closed reduction and unilateral external fixator, along with percutaneous pin fixation provides move stable fixation for type C1 distal radius fractures. Gradual removal of external fixator further facilitatse the recovery of wrist joint function.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
External Fixators
;
Aged
;
Aged, 80 and over
;
Bone Wires
;
Fracture Fixation/instrumentation*
;
Wrist Fractures
6.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
7.Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures.
Guang-Yao LI ; Yong-Zhong CHENG ; Huan LIU ; Jun-Jie JIANG ; Yong-Yao LI ; Yang CHEN ; Yu-Xiang YAO
China Journal of Orthopaedics and Traumatology 2025;38(1):66-80
OBJECTIVE:
Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.
METHODS:
PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database. The database will be established until June 30, 2023. The included studies were extracted according to the Cochrane Handbook (Version 6.3, 2022) for information extraction and literature quality evaluation. RevMan 5.4 was used to evaluate the risk of Publication bias, test heterogeneity and Perform Meta-analysis. The outcome indicators were:imaging anatomy indicators (volar inclination angle, ulnar deviation angle, radial height), wrist joint mobility (flexion, extension, rotation, ulnar deviation), complication rate, and comparison of surgical treatments (operative blood loss, operation time, hospitalization time, fracture healing time) and wrist joint function scores and related scales.
RESULTS:
(1) A total of 28 studies were included, with a total of 2 192 patients, including 1 096 cases in the plate internal fixation group and 1 096 cases in the external fixation group.(2) Meta analysis results showed:the surgical treatment situation of the external fixation group:surgical blood loss MD=-37.93, 95%CI(-48.54, -27.31), P<0.000 01;operation time MD=-31.58, 95%CI(-48.96, -14.20), P<0.000 4;hospitalization time MD=-4.58, 95%CI(-5.44, -3.71), P<0.000 01;the fracture healing time MD=-0.88, 95%CI(-1.35, -0.41), P<0.000 2, which were significantly better than that of the plate internal fixation group(P<0.05).(3) The two groups:palmar inclination angle MD=-0.17, 95%CI(-0.95, 0.61), P=0.68;ulnar declination MD=0.22, 95%CI(-0.73, 1.17), P=0.65, radial height MD=-0.24, 95%CI(-1.15, 0.67), P=0.60;flexion and extension MD=-5.63, 95%CI(-11.85, 0.58), P=0.08;rotation MD=-5.80, 95%CI(-12.77, 1.17), P=0.10, radioulnar deviation MD=-2.86, 95%CI(-10.87, 5.15), P=0.48;complication rate RR=0.96, 95%CI(0.63, 1.46), P=0.83;Gartland-Werley clinical wrist score MD=0.13, 95%CI(-0.80, 1.06), P=0.78;excellent and good rate of Gartland-Werley wrist clinical score RR=0.93, 95%CI(0.87, 1.01), P=0.08;excellent and good rate of Cooney wrist score RR=0.99, 95%CI(0.62, 1.59), P=0.98;wrist DASH score MD=-4.67, 95%CI(-14.96, 5.62), P=0.37;the differences were not significant (P>0.05).
CONCLUSION
Compared with internal fixation with plate, external fixation can significantly reduce the amount of surgical bleeding, shorten the operation time, hospitalization time and fracture healing time, and its imaging anatomical indicators, wrist mobility, and complications can be significantly reduced in treating AO-C distal radius fractures. Rates and wrist function scores were equivalent.
Humans
;
External Fixators
;
Bone Plates
;
Radius Fractures/surgery*
;
Fracture Fixation/methods*
;
Fracture Fixation, Internal
;
Wrist Fractures
8.Dorsally displaced distal radial double-column Die-punch fractures by dorsal approach external fixator combined with Kirschner wires.
Fu-de JIAO ; Jing-Wei ZHANG ; Li-Mei ZHU ; Lin AN ; Yun-Qiang ZHUANG ; Jian-Ming CHEN
China Journal of Orthopaedics and Traumatology 2025;38(1):87-91
OBJECTIVE:
Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.
METHODS:
Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old. Recorded the preoperative and the final follow-up Cooney wrist function scores for the patients. The fracture healing time, and occurrence of complications were recorded.
RESULTS:
All 15 patients were followed up ranged from 12 to 16 months post-operation. All fractures achieved bony union, healing time ranging form 8 to 16 weeks. Not a single patient exhibited complications such as surgical site infection, fracture redislocation, or tendon injury. All individuals had their Kirschner wires and external fixation devices removed six weeks post-operatively and commenced rehabilitative therapy for wrist articulation. The Cooney wrist function scores at preoperative and ranged from 5 to 45 scores, at the latest follow-up ranged from 65 to 100 scores. At the final follow-up, the results were assessed as excellent in 10 patients, good in 4 patients, and fair in 1 patient.
CONCLUSION
The clinical efficacy of treating distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires is satisfactory.
Humans
;
Male
;
Female
;
Middle Aged
;
Adult
;
External Fixators
;
Bone Wires
;
Aged
;
Retrospective Studies
;
Radius Fractures/physiopathology*
;
Young Adult
;
Fracture Fixation/methods*
9.Clinical application of special fluoroscopy method in the treatment of distal radius fractures with volar locking plate.
Rong ZHANG ; He-Ming NIU ; Tao GUO ; Ping-Feng XIE ; Jia-Ming WU ; Jia-Bing XIE ; Lin WANG
China Journal of Orthopaedics and Traumatology 2023;36(2):128-132
OBJECTIVE:
The relationship between the distal screws and the wrist articular surface was assessed by the additional lateral oblique fluoroscopic view during the operation, and the dorsal tangential view of the wrist was used to observe whether the distal screw penetrated the dorsal cortex, so as to evaluate the clinical efficacy of the volar locking plate in the treatment of distal radius fractures.
METHODS:
From January 2020 to June 2021, 45 cases of fresh distal radius fractures were treated using the volar Henry's approach, including 20 males and 25 females, aged from 32 to 75 years old with an average of (52.4±8.1) years old. During the operation, they were divided into 2 groups according to the different intraoperative fluoroscopic views:the control group of 20 cases, treated with standard anteroposterior and lateral fluoroscopic view;25 cases in the observation group, additional lateral oblique fluoroscopic view and dorsal tangential view of the wrist were taken. The wrist joint function score and postoperative complications were evaluated at 6 weeks, 3 and 6 months after operation between two groups.
RESULTS:
All 45 patients were followed up and the duration ranged from 6 to 14 months, with an average of (10.8±1.7) months, all patients achieved bone union and the incision healed well. The incidence of postoperative complications in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). In terms of Gartland-Werley score of wrist joint function, the score of wrist function in the observation group was (4.58±1.31) at 6 weeks, (2.98±0.63) at 3 months and (1.95±0.65) at 6 months post-operatively, which were better than those in the control group (6.32±1.96) at 6 weeks, (3.63±0.76) at 3 months and (2.43±0.73) at 6 months. The difference was statistically significant (P<0.05). In the observation group, 7/25 cases(28%) were found to have screw penetration during the operation by additional lateral oblique and dorsal tangential radiograph fluoroscopic views of wrist.
CONCLUSION
The addition of lateral oblique and dorsal tangential during the operation could improve the accuracy of distal screw placement, reduce postoperative complications, and achieve early functional exercise.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Wrist Fractures
;
Radius Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Fluoroscopy/methods*
;
Bone Plates
;
Postoperative Complications
10.Dorsal plate assisted fixation of dorsal lunate fossa fracture of distal radius.
Jun QIAN ; Kai-Ming JIANG ; Kun-Zhi SU ; Jun-Hong LIN ; Mei-Yuan FANG
China Journal of Orthopaedics and Traumatology 2023;36(8):782-785
OBJECTIVE:
To explore clinical efficacy of dorsal plate assisted fixation of dorsal lunate fossa fracture block of distal radius.
METHODS:
From January 2019 to January 2022, 30 patients were treated with dorsal plate assisted fixation of dorsal lunate fossa fracture of distal radius, including 13 males and 17 females, aged from 42 to 68 years old with an average of (48.7±5.6) years old;According to Doi fracture classification, 24 patients were type 3 blocks and 6 patients were type 4 blocks. The degree of palmar angle of anterior and posterior distal radius was fixed by dorsal steel plate during operation. Fracture healing and functional recovery of wrist were observed after operation. Functional evaluation was performed by Gartland and Werley scoring system at 12 months after operation.
RESULTS:
All patients were followed up from 12 to 13 months with an average of (11.3±0.9) months. All fractures healed for 4 to 5 months with an average of(4.7±0.8) months. Median palpal inclination of anterior and posterior distal radius fixed by dorsal plate was 5.30°(4.85°, 6.03°), 12.45°(11.98°, 13.43°) respectively, and had statistical difference( P<0.01). Gartland and Werley scores was (1.1±0.4) at 12 months afteropertaion, and 27 patients got excellent result and 3 good.
CONCLUSION
Dorsal plate assisted fixation of dorsal lunate fossa fractures is beneficial to reduction and stabilization of displaced dorsal fractures and restoration of palmar inclination.
Female
;
Male
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Radius/surgery*
;
Lunate Bone/surgery*
;
Upper Extremity
;
Wrist Joint
;
Wrist
;
Fractures, Bone

Result Analysis
Print
Save
E-mail