1.Application of automatic injection device based on automatic hemostasis in injection of radiopharmaceutical bolus injection.
Jin LI ; Wenhong FAN ; Jianxiong MA ; Wei ZHOU ; Xinxin PANG ; Cungui TIAN ; Guohui YANG ; Yan WANG ; Na ZHAO
Journal of Biomedical Engineering 2023;40(2):320-326
In clinical practice, radiopharmaceutical dynamic imaging technology requires the bolus injection method to complete injection. Due to the failure rate and radiation damage of manual injection, even experienced technicians still bear a lot of psychological burden. This study combined the advantages and disadvantages of various manual injection modes to develop the radiopharmaceutical bolus injector, and explored the application of automatic injection in the field of bolus injection from four aspects: radiation protection, occlusion response, sterility of injection process and effect of bolus injection. Compared with the current mainstream manual injection method, the bolus manufactured by the radiopharmaceutical bolus injector based on the automatic hemostasis method had a narrower full width at half maximum and better repeatability. At the same time, radiopharmaceutical bolus injector had reduced the radiation dose of the technician's palm by 98.8%, and ensured more efficient vein occlusion recognition performance and sterility of the entire injection process. The radiopharmaceutical bolus injector based on automatic hemostasis has application potential in improving the effect and repeatability of bolus injection.
Radiopharmaceuticals
;
Injections
;
Hand
3.Application of micro-bolus injection and piezoelectric sensors to improve the safety of radiopharmaceuticals bolus injection.
Jin LI ; Yan WANG ; Jianxiong MA ; Xinxin PANG ; Wei ZHOU ; Cungui TIAN ; Guohui YANG ; Na ZHAO
Journal of Biomedical Engineering 2023;40(5):982-988
Radiopharmaceutical dynamic imaging typically necessitates intravenous injection via the bolus method. However, manual bolus injection carries the risk of handling errors as well as radiological injuries. Hence, there is potential for automated injection devices to replace manual injection methods. In this study, the effect of micro-bolus pulse injection technology was compared and verified by radioactive experiments using a programmable injection pump, and the overall bubble recognition experiment and rat tail vein simulation injection verification were performed using the piezoelectric sensor preloading method. The results showed that at the same injection peak speed, the effective flushing volume of micro-bolus pulse flushing (about 83 μL/pulse) was 49.65% lower than that of uniform injection and 25.77% lower than that of manual flushing. In order to avoid the dilution effect of long pipe on the volume of liquid, the use of piezoelectric sensor for sealing preloading detection could accurately predict the bubbles of more than 100 μL in the syringe. In the simulated injection experiment of rat tail vein, when the needle was placed in different tissues by preloading 100 μL normal saline, the piezoelectric sensor fed back a large difference in pressure attenuation rate within one second, which was 2.78% in muscle, 17.28% in subcutaneous and 54.71% in vein. Micro-bolus pulse injection method and piezoelectric sensor sealing preloading method have application potential in improving the safety of radiopharmaceutical automatic bolus injection.
Animals
;
Rats
;
Radiopharmaceuticals/administration & dosage*
4.The correlation between metabolic parameters in (18)F-FDG PET-CT and solid and micropapillary histological subtypes in lung adenocarcinoma.
Yue GUO ; Zhi Ming YAO ; Min CHEN ; Cong Xia CHEN
Chinese Journal of Oncology 2022;44(6):555-561
Objective: Solid and micropapillary pattern are highly invasive histologic subtypes in lung adenocarcinoma and are associated with poor prognosis while the biopsy sample is not enough for the accurate histological diagnosis. This study aims to assess the correlation and predictive efficacy between metabolic parameters in (18)F-fluorodeoxy glucose positron emission tomography/computed tomography ((18)F-FDG PET-CT), including the maximum SUV (SUV(max)), metabolic tumor volume (MTV), total lesion glycolysis (TLG) and solid and micropapillary histological subtypes in lung adenocarcinoma. Methods: A total of 145 resected lung adenocarcinomas were included. The clinical data and preoperative (18)F-FDG PET-CT data were retrospectively analyzed. Mann-Whitney U test was used for the comparison of the metabolic parameters between solid and micropapillary subtype group and other subtypes group. Receiver operating characteristic (ROC) curve and areas under curve (AUC) were used for evaluating the prediction efficacy of metabolic parameters for solid or micropapillary patterns. Univariate and multivariate analyses were conducted to determine the prediction factors of the presence of solid or micropapillary subtypes. Results: Median SUV(max) and TLG in solid and papillary predominant subtypes group (15.07 and 34.98, respectively) were significantly higher than those in other subtypes predominant group (6.03 and 10.16, respectively, P<0.05). ROC curve revealed that SUV(max) and TLG had good efficacy for prediction of solid and micropapillary predominant subtypes [AUC=0.811(95% CI: 0.715~0.907) and 0.725(95% CI: 0.610~0.840), P<0.05]. Median SUV(max) and TLG in lung adenocarcinoma with the solid or micropapillary patterns (11.58 and 22.81, respectively) were significantly higher than those in tumors without solid and micropapillary patterns (4.27 and 6.33, respectively, P<0.05). ROC curve revealed that SUV(max) and TLG had good efficacy for predicting the presence of solid or micropapillary patterns [AUC=0.757(95% CI: 0.679~0.834) and 0.681(95% CI: 0.595~0.768), P<0.005]. Multivariate logistic analysis showed that the clinical stage (Stage Ⅲ-Ⅳ), SUV(max) ≥10.27 and TLG≥7.12 were the independent predictive factors of the presence of solid or micropapillary patterns (P<0.05). Conclusions: Preoperative SUV(max) and TLG of lung adenocarcinoma have good prediction efficacy for the presence of solid or micropapillary patterns, especially for the solid and micropapillary predominant subtypes and are independent factors of the presence of solid or micropapillary patterns.
Adenocarcinoma of Lung/diagnostic imaging*
;
Fluorodeoxyglucose F18/metabolism*
;
Humans
;
Lung Neoplasms/pathology*
;
Multimodal Imaging/methods*
;
Positron Emission Tomography Computed Tomography
;
Positron-Emission Tomography/methods*
;
Prognosis
;
Radiopharmaceuticals
;
Retrospective Studies
;
Tomography, X-Ray Computed/methods*
;
Tumor Burden
5.Pretreatment evaluation of 18F-FDG PET-CT in extranodal NK/T-cell lymphoma.
Pan PENG ; Ning WU ; Xiu Li TAO ; Ying LIU ; Lyu LYU ; Xin CHENG
Chinese Journal of Oncology 2022;44(4):370-376
Objective: To investigate the clinical value of pretreatment 18F-fluorodeoxy glucose positron emission tomography/computed tomography (18F-FDG PET-CT) in extranodal NK/T-cell lymphoma. Methods: Eighty-one patients with pathologically confirmed extranodal NK/T-cell lymphoma and pretreatment with PET-CT scan in Cancer Hospital, Chinese Academy of Medical Sciences from August 2006 to December 2017 were enrolled in the study. The clinical, follow-up and imaging data were analyzed retrospectively. The relationship between maximum standard uptake value (SUVmax) and prognosis were evaluated by Mann-Whitney U test and Spearman rank correlation analysis. Results: Among the 81 patients, 98.8% (80/81) were upper aerodigestive tract (UAT) involved. Lesions at extra-UAT sites were detected in 7 cases, involving parotid gland (n=1), breast (n=1), spleen (n=1), pancreas (n=1), skin and subcutaneous soft tissue (n=1), muscle (n=1), lung (n=2) and bone (n=3). Lymph node involvement were demonstrated in 33 cases. All of the lesions had increased uptake of PET, the median SUVmax was 8.6. PET-CT changed staging in 15 cases, and 12 cases were adjusted treatment methods. 21 cases were changed radiotherapy target because of PET-CT. The 1-, 2-year progression-free survival (PFS) rates were 88.7% and 80.3% while 1-, 2-year overall survival (OS) rates were 97.2% and 94.4% respectively. The median SUVmax of patients with local lymph nodes involvement was significantly higher than those without local lymph nodes involvement (P=0.007). The SUVmax was positively associated with Ann Arbor stage (r=0.366, P=0.001), lactate dehydrogenase (r=0.308, P=0.005) and Ki-67 level (r=0.270, P=0.017). The SUVmax was inversely associated with lymphocyte count (r=-0.324, P=0.003) and hemoglobin content (r=-0.225, P=0.043). Conclusions: Extranodal NK/T-cell lymphoma predominantly occurs in extra-nodal organs, mainly in the upper respiratory and gastrointestinal tracts, with marked FDG-addiction. Compared with conventional imaging, 18F-FDG PET-CT is sensitive and comprehensive in detecting extra-nodal NK/T-cell lymphoma involvement, assisting in accurate clinical staging and treatment planning. Pretreatment SUVmax is potential for prognosis evaluation since it is correlated with prognostic factors.
Fluorodeoxyglucose F18
;
Humans
;
Lymphoma, Extranodal NK-T-Cell/radiotherapy*
;
Positron Emission Tomography Computed Tomography/methods*
;
Prognosis
;
Radiopharmaceuticals
;
Retrospective Studies
6.Application of Raman-based technologies in the detection of urological tumors.
Zhe HAO ; Shu Hua YUE ; Li Qun ZHOU
Journal of Peking University(Health Sciences) 2022;54(4):779-784
Urinary system tumors affect a huge number of individuals, and are frequently recurrent and progressing following surgery, necessitating lifelong surveillance. As a result, early and precise diagnosis of urinary system cancers is important for prevention and therapy. Histopathology is now the golden stan-dard for the diagnosis, but it is invasive, time-consuming, and inconvenient for initial diagnosis and re-gular follow-up assessment. Endoscopy can directly witness the tumor's structure, but intrusive detection is likely to cause harm to the patient's organs, and it is apt to create other hazards in frequently examined patients. Imaging is a valuable non-invasive and quick assessment tool; however, it can be difficult to define the type of lesions and has limited sensitivity for early tumor detection. The conventional approaches for detecting tumors have their own set of limitations. Thus, detection methods that combine non-invasive detection, label-free detection, high sensitivity and high specificity are urgently needed to aid clinical diagnosis. Optical diagnostics and imaging are increasingly being employed in healthcare settings in a variety of sectors. Raman scattering can assess changes in molecular signatures in cancer cells or tissues based on the interaction with vibrational modes of common molecular bonds. Due to the advantages of label-free, strong chemical selectivity, and high sensitivity, Raman scattering, especially coherent Raman scattering microscopy imaging with high spatial resolution, has been widely used in biomedical research. And quantity studies have shown that it has a good application in the detection and diagnosis of bladder can-cer, renal clear cell carcinoma, prostate cancer, and other cancers. In this paper, several nonlinear imaging techniques based on Raman scattering technology are briefly described, including Raman spectroscopy, coherent anti-Stokes Raman scattering, stimulated Raman scattering, and surface-enhanced Raman spectroscopy. And we will discuss the application of these techniques for detecting urologic malignancy. Future research directions are predicted using the advantages and limitations of the aforesaid methodologies in the research. For clinical practice, Raman scattering technology is intended to enable more accurate, rapid, and non-invasive in early diagnosis, intraoperative margins, and pathological grading basis for clinical practice.
Humans
;
Male
;
Microscopy/methods*
;
Radiopharmaceuticals
;
Spectrum Analysis, Raman/methods*
;
Technology
;
Urologic Neoplasms/diagnosis*
8.Design and Test of Automatic Dispensing and Injecting System for Positron Radiopharmaceuticals.
Ning GUO ; Tong WANG ; Li HUO ; Fang LI ; Li-Jie LIU ; Yi LI ; Jian-Tao BA
Acta Academiae Medicinae Sinicae 2021;43(3):429-434
Objective To design a novel automatic dispensing and injecting system of positron radiopharmaceuticals,for precise dose dispensing,simplified operation,and reduction of occupational radiation exposure. Methods The automatic dispensing and injecting system was fabricated with tungsten alloy as the shielding material.The performance and radiation protection of the device were assessed. Results The total time of injection using the automatic dispensing and injecting system was about 60 s.The ratio of successful injection in stability test was 100%.The deviation of the dispensing dose with the system was ≤3%.With the tungsten alloy shield(40 mmPb of the cabinet,60 mmPb of the countertop,15 mmPb of the protective shield,and 50 mmPb of the inbuilt jar for radiopharmaceuticals),the average dose rate at 30 cm from the device was 1.44 μSv/h,and the radiation dose at the operator's extremity was reduced by 99%. Conclusions This automatic dispensing and injecting system of positron radiopharmaceuticals is easy to operate with precise dispensing dose.It is safe and meets the requirements of radiation protection.
Electrons
;
Occupational Exposure/analysis*
;
Radiation Dosage
;
Radiation Protection
;
Radiopharmaceuticals
10.Progress in the clinical application and correlation between glucose transporter-1 and
Journal of Biomedical Engineering 2021;38(2):399-404
Because of the unobvious early symptoms and low 5-year survival rate, the early diagnosis and treatment is of great significance for patients with non-small cell lung cancer. Glucose transporter-1 is the most widely distributed glucose transporters in various tissue cells in the human body, whose expression in non-small cell lung cancer is closely related to the histological types, lymph node metastasis, degree of differentiation, progression and prognosis.
Carcinoma, Non-Small-Cell Lung/diagnostic imaging*
;
Fluorodeoxyglucose F18
;
Glucose Transport Proteins, Facilitative
;
Glucose Transporter Type 1
;
Humans
;
Lung Neoplasms/diagnostic imaging*
;
Positron Emission Tomography Computed Tomography
;
Positron-Emission Tomography
;
Radiopharmaceuticals

Result Analysis
Print
Save
E-mail