1.Design of a novel, modular, mouth retractor: A concept testing study
Miguel Sandino O. Aljibe ; Airene Maria C. Apacible ; Philip B. Fullante
Acta Medica Philippina 2025;59(Early Access 2025):1-10
BACKGROUND AND OBJECTIVES
Mouth retractors are essential in ensuring efficient yet safe exposure of the oral cavity and oropharynx. However, when applied improperly or haphazardly, retractors can cause tissue injuries and compromise patient safety. In addition, there are gaps in the usability of existing designs. This study aimed to identify the issues encountered by otorhinolaryngology surgeons in the use of commercially available mouth retractors, design and fabricate an improved retractor, and explore the use of additive manufacturing (popularly known as 3D printing) for retractor prototyping.
METHODSThe study used the United States Food and Drug Administration (US FDA) Design Control as its framework. End-user requirements from otorhinolaryngologists were collected through key informant interviews. Results were organized into a Design Input template which was used to guide the design and development process. Prototype designs were iteratively created using computer-aided design software and 3D printing. Once design specifications were satisfied, a beta prototype was fabricated and given to another cohort of otorhinolaryngologists. The participants assessed the usability of the beta prototype. System Usability Scale (SUS) was used to quantify participant's feedback.
RESULTSFive designs were created in the course of the study. The final prototype was fabricated using a Stereolithography (SLA) 3D printer. Several features were developed to address user requirements. The primary modification was to make the retractor modular to facilitate easier and shorter mounting and assembly. Gingival injury was addressed with the replacement of the maxillary alveolus hook with support bars. Five participants evaluated the beta prototype which received a mean SUS score of 75, well above the 50th percentile threshold.
CONCLUSIONThis study demonstrates the applicability of the US FDA Design Control Process in the local setting to improve the mouth retractor design. Clinical and ergonomic issues were identified and design solutions were proposed and some have been implemented in a low-fidelity prototype. Results of the small-scale usability test suggest that the present form factor can be the basis for further iterations. Future studies can implement the proposed features to address other clinical and ergonomic needs.
Human ; 3d Printing ; Printing, Three-dimensional ; Devices, Medical ; Equipment And Supplies
2.Digital study of IdebergⅡregional pelvic fracture anatomical plate based on 3D metal printing technology.
Yi ZHANG ; Jia-Kai ZHANG ; Jun-Long WU ; Yi ZHENG
China Journal of Orthopaedics and Traumatology 2025;38(3):293-297
OBJECTIVE:
To establish digital model of Ideberg typeⅡregional glenoid fracture anatomical plate with 3D metal printing technology.
METHODS:
The scapular imaging data of a 34-year-old healthy male volunteer were retrospectively selected. Mimics 15.01, NX 12.0 and other software were used to design Ideberg typeⅡ regional scapular fracture guide plate system. STL data were input into a metal 3D printer to print 1∶1 scapular model and anatomical plate of scapular pelvis with guide sleeve. The fit of the plate was tested in vitro and the accuracy of the screw position was evaluated by imaging. The printing time of scapular model, design of the nail path and making time of the anatomic guided plate were recorded.
RESULTS:
3D metal-printed Ideberg typeⅡ guide plate for scapular fracture fitted well to 3D printed scapular model, the locking screw was oriented accurately, and X-ray and CT showed good screw position. The printing time of scapula model, time of nail path design and special-shaped anatomical guide plate production were 52.0, 15.0 and 320 min, respectively.
CONCLUSION
Anatomical plates based on 3D metal printing technology could achieve good adhesion of Ideberg typeⅡ regional fractures and precise screw placement, providing a new and accurate surgical method for the treatment of Ideberg typeⅡ glenoid fractures.
Humans
;
Printing, Three-Dimensional
;
Male
;
Adult
;
Bone Plates
;
Fractures, Bone/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Pelvic Bones/surgery*
;
Metals
;
Scapula/surgery*
;
Models, Anatomic
3.Manual reduction combined with 3D printed small splint in treating humeral shaft fractures.
Qiang WANG ; Yan-Kui LENG ; Bo ZHAI ; Jia-Yi XU ; Geng-Sheng JI
China Journal of Orthopaedics and Traumatology 2025;38(4):364-370
OBJECTIVE:
To analyze the clinical efficacy of manual reduction combined with 3D printing small splint external fixation and synchronous manual reduction combined with traditional small splint external fixation in the treatment of humeral shaft.
METHODS:
Between January 2021 and December 2022, 40 patients with humeral shaft fractures were treated with 3D printing small splints and traditional small splints. They were divided into 3D group and traditional group according to different fixation methods. Among them, there were 15 males and 5 females in the 3D group, aged from 20 to 52 years old with an average of (36.3±15.6) years old. In the traditional group there were 17 males and 3 females, aged from16 to 51 years old with an average of (32.9±17.2) years old. The occurrence of complications, duration of fracture healing, rate of fracture healing, subjective evaluation scores for brace comfort at 1 week and 4 weeks, as well as the Constant-Murley shoulder function score and Mayo elbow function score at 8 weeks and 16 weeks were compared between the two groups.
RESULTS:
All patients were followed up for 16 weeks. The 3D group did not experience any complications, while there were two cases of complications in the traditional group. However, this difference was not found to be statistically significant (χ2=2.105, P=0.146). The fracture healing time of the 3D group (90.1±4.5) days was significantly shorter compared to that of the traditional group (93.3±3.8) days (P<0.05). The subjective evaluation scores for brace comfort in the 3D group (53.7±2.3) points and (62.8±1.1) points were significantly higher than those in the traditional group (45.6±2.4) points and (52.3±1.4) points at 1 and 4 weeks after reduction (P<0.05). After 8 weeks of reduction, the Constant-Murley shoulder function score in the 3D group was(68.1±5.3) points, which demonstrated a statistically significant improvement compared to the traditional group(54.3±4.9) points (P<0.05). However, at 16 weeks post-reduction, there were no significant differences observed between the two groups (P>0.05). The Mayo elbow function score of the 3D group (84.1±7.5) points was significantly superior to that of the traditional group (79.5±6.8) points at 8 weeks post-reduction (P<0.05). However, there was no statistically significant difference between the two groups at 16 weeks post-reduction (P>0.05).
CONCLUSION
For humeral shaft fractures with conservative treatment indications, manual reduction combined with 3D printed small splints is a good choice for treatment. The patient's comfort level is higher, which can not only reduce the occurrence of complications, but also improve the fracture healing rate and joint function to a certain extent, and improve the patient's quality of life.
Humans
;
Female
;
Male
;
Adult
;
Middle Aged
;
Humeral Fractures/physiopathology*
;
Printing, Three-Dimensional
;
Splints
;
Adolescent
;
Young Adult
;
Fracture Healing
4.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome
5.Application of 3D-printed auxiliary guides in adolescent scoliosis surgery.
Dong HOU ; Jian-Tao WEN ; Chen ZHANG ; Jin HUANG ; Chang-Quan DAI ; Kai LI ; Han LENG ; Jing ZHANG ; Shao-Bo YANG ; Xiao-Juan CUI ; Juan WANG ; Xiao-Yun YUAN
China Journal of Orthopaedics and Traumatology 2025;38(11):1119-1125
OBJECTIVE:
To investigate the accuracy and safety of pedicle screw placement using 3D-printed auxiliary guides in scoliosis correction surgery for adolescents.
METHODS:
A retrospective analysis was conducted on the clinical data of 51 patients who underwent posterior scoliosis correction surgery from January 2020 to March 2023. Among them, there were 35 cases of adolescent idiopathic scoliosis and 16 cases of congenital scoliosis. The patients were divided into two groups based on the auxiliary tool used:the 3D-printed auxiliary guide screw placement group (3D printing group) and the free-hand screw placement group (free-hand group, without auxiliary tools). The 3D printing group included 32 patients (12 males and 20 females) with an average age of (12.59±2.60) years;the free-hand group included 19 patients (7 males and 12 females) with an average age of (14.58±3.53) years. The two groups were compared in terms of screw placement accuracy and safety, spinal correction rate, intraoperative blood loss, number of intraoperative fluoroscopies, operation time, hospital stay, and preoperative and last follow-up scores of the Scoliosis Research Society-22 (SRS-22) questionnaire.
RESULTS:
A total of 707 pedicle screws were placed in the two groups, with 441 screws in the 3D printing group and 266 screws in the free-hand group. All patients in both groups successfully completed the surgery. There was a statistically significant difference in operation time between the two groups (P<0.05). The screw placement accuracy rate of the 3D printing group was 95.46% (421/441), among which the Grade A placement rate was 89.34% (394/441);the screw placement accuracy rate of the free-hand group was 86.47% (230/266), with a Grade A placement rate of 73.31% (195/266). There were statistically significant differences in the accuracy of Grade A, B, and C screw placements between the two groups (P<0.05), while no statistically significant differences were observed in intraoperative blood loss, number of fluoroscopies, correction rate, or hospital stay (P>0.05). In the SRS-22 questionnaire scores, the scores of functional status and activity ability, self-image, mental status, and pain of patients in each group at the last follow-up were significantly improved compared with those before surgery (P<0.05), but there were no statistically significant differences in all scores between the two groups (P>0.05).
CONCLUSION
In scoliosis correction surgery, compared with traditional free-hand screw placement, the use of 3D-printed auxiliary guides for screw placement significantly improves the accuracy and safety of screw placement and shortens the operation time.
Humans
;
Male
;
Scoliosis/surgery*
;
Female
;
Adolescent
;
Printing, Three-Dimensional
;
Retrospective Studies
;
Pedicle Screws
;
Child
6.Effect of slurry proportion on the microstructure and properties of dental lithium disilicate ceramics manufactured through 3D printing.
Baoxin LIN ; Xiaoxuan CHEN ; Ruyi LI ; Qianbing WAN ; Xibo PEI
West China Journal of Stomatology 2025;43(2):175-182
OBJECTIVES:
This study aims to use 3D prin-ting technology based on the principle of stereo lithography apparatus (SLA) to shape dental lithium disilicate ceramics and study the effects of different slurry proportions on the microstructure and properties of heat-treated samples.
METHODS:
The experimental group comprised lithium disilicate ceramics manufactured through SLA 3D printing, and the control group comprised lithium disilicate ceramics (IPS e.max CAD) fabricated through commercial milling. An array of different particle sizes of lithium disilicate ceramic powder materials (nano and micron) was selected for mixing with photocurable acrylate resin. The proportion of experimental raw materials was adjusted to prepare five groups of ceramic slurries for 3D printing (Groups S1-S5) on the basis of rheological properties, stability, and other factors. Printing, debonding, and sintering were conducted on the experimental group with the optimal ratio, followed by measurements of microstructure, crystallographic information, shrinkage, and mechanical properties.
RESULTS:
Five groups of lithium disilicate ceramic slurries were prepared, of which two groups with high solid content (75%) (Groups S2 and S3) were selected for 3D printing. X-ray diffraction and scanning electron microscopy results showed that lithium disilicate was the main crystalline phase in Groups S2 and S3, and its microstructure was slender, uniform, and compact. The average grain sizes of Groups S2 and S3 were (559.79±84.58) nm and (388.26±61.49) nm, respectively (P<0.05). Energy spectroscopy revealed that the samples in the two groups contained a high proportion of Si and O elements. After heat treatment, the shrinkage rate of the two groups of ceramic samples was 18.00%-20.71%. Test results revealed no statistical difference in all mechanical properties between Groups S2 and S3 (P>0.05). The flexural strengths of Groups S2 and S3 were (231.79±21.71) MPa and (214.86±46.64) MPa, respectively, which were lower than that of the IPS e.max CAD group (P<0.05). The elasticity modulus of Groups S2 and S3 were (87.40±12.99) GPa and (92.87±19.76) GPa, respectively, which did not significantly differ from that of the IPS e.max CAD group (P>0.05). The Vickers hardness values of Groups S2 and S3 were (6.53±0.19) GPa and (6.25±0.12) GPa, respectively, which were higher than that of the IPS e.max CAD group (P<0.05). The fracture toughness values of Groups S2 and S3 were (1.57±0.28) MPa·m0.5 and (1.38±0.17) MPa·m0.5, respectively, which did not significantly differ from that of the IPS e.max CAD group (P>0.05).
CONCLUSIONS
The combination of lithium disilicate ceramic powders with different particle sizes can yield a slurry with high solid content (75%) and suitable viscosity and stability. The dental lithium disilicate ceramic material is successfully prepared by using 3D printing technology. The 3D-printed samples show a small shrinkage rate after heat treatment. Their microstructure conforms to the crystal phase of lithium disilicate ceramics, and their mechanical properties are close to those of milled lithium disilicate ceramics.
Printing, Three-Dimensional
;
Dental Porcelain/chemistry*
;
Ceramics/chemistry*
;
Materials Testing
;
Particle Size
7.Clinical and histological evaluation of three-dimensional printing individualized titanium mesh for alveolar bone defect repair.
Pengyu ZHAO ; Gang CHEN ; Yi CHENG ; Chao WANG ; Dan CHEN ; Haitao HUANG
West China Journal of Stomatology 2025;43(4):592-602
OBJECTIVES:
To evaluate the osteogenic efficacy of three-dimensional printing individualized titanium mesh (3D-PITM) as a scaffold material in guided bone regeneration (GBR).
METHODS:
1) Patients undergoing GBR for alveolar bone defects were enrolled as study subjects, and postoperative healing complications were recorded. 2) Postoperative cone beam computed tomography (CBCT) scans acquired at least 6 months post-surgery were used to calculate the percentage of actual bone formation volume. 3) Alveolar bone specimens were collected during the first-stage implant surgery for histomorphometric analysis. This analysis quantitatively measured the proportions of newly formed bone and newly formed unmineralized bone within the specimens. Specimens were categorized into three groups based on healing complications (good healing group, wound dehiscence group, 3D-PITM exposure group) to compare differences in the proportions of newly formed bone and newly formed unmineralized bone.
RESULTS:
1) Twelve patients were included. Guided bone regeneration failed in one patient, and 3D-PITM exposure occurred in three patients (exposure rate: 25%). 2) The mean percentage of actual bone formation volume in the 11 successful guided bone regeneration cases was 95.23%±28.85%. 3) Histomorphometric analysis revealed that newly formed bone constituted 40.35% of the alveolar bone specimens, with newly formed unmineralized bone accounting for 13.84% of the newly formed bone. Intergroup comparisons showed no statistically significant differences (P>0.05) in the proportions of newly formed bone or newly formed unmineralized bone between the good healing group and the wound dehiscence group or the 3D-PITM exposure group.
CONCLUSIONS
3D-PITM enables effective bone augmentation. Radiographic assessment demonstrated favorable bone formation volume, while histological analysis confirmed substantial formation of newly formed mineralized bone within the surgical site.
Humans
;
Printing, Three-Dimensional
;
Titanium
;
Cone-Beam Computed Tomography
;
Bone Regeneration
;
Osteogenesis
;
Surgical Mesh
;
Tissue Scaffolds
;
Alveolar Process/surgery*
;
Adult
;
Male
;
Middle Aged
;
Female
;
Wound Healing
;
Guided Tissue Regeneration, Periodontal/methods*
;
Alveolar Bone Loss/surgery*
8.Digital design and manufacturing method of double constrained split guide for orthodontic miniscrew implantation.
Xin DU ; Aonan WEN ; Zixiang GAO ; Zhihua LI ; Sheng ZHANG ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(4):603-612
This study explored a novel digital design and fabrication method for a double constrained split orthodontic miniscrew guide to improve the accuracy and safety of clinical miniscrew implantation and reduce related complications. A patient requiring miniscrew implantation was selected, and data were acquired using cone beam computed tomography (CBCT) and intraoral optical scanning. For the construction of a double constrained split guide including a screw-hole guide and an insertion rod guide, different types of software such as Mimics 24.0, Geomagic wrap 2021, and Materialise magics 21.0 were utilized for 3D reconstruction, model integration, and guide design. The guide was then fabricated via laser metal 3D printing. Model and intraoral try-in results demonstrated that the guide fitted well and was stable. Postoperative CBCT verified that the final miniscrew implantation site was consistent with the preoperative design, and no related complications occurred. This double constrained split orthodontic miniscrew guide provides a precise and safe digital solution for clinical miniscrew implantation.
Humans
;
Bone Screws
;
Cone-Beam Computed Tomography
;
Printing, Three-Dimensional
;
Orthodontic Anchorage Procedures/instrumentation*
;
Imaging, Three-Dimensional
;
Computer-Aided Design
9.Preliminary study on the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
Xin LI ; Yuzong LU ; Yongtao YANG ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(5):689-695
OBJECTIVES:
This study aimed to investigate the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
METHODS:
Ten digital impressions of patients undergoing continuous crowns or fixed bridge restoration supported by two implants were obtained, and resin models with implant replicas were 3D printed. Scanning rods were fixed on the replicas 3, 7, and 14 days after printing. The 3D, linear, and angular deviations of the scanning rods at different times were analyzed through Geomagic Wrap 2021 software.
RESULTS:
The position of the replicas shifted mesiolingually, in the same direction as the shrinkage of the model. From day 7 onward, the 3D, distance linear, and angular deviations of the replicas (scanning rod) significantly increased compared with those on the 3rd day (P<0.05). On the 14th day, the changes were even more pronounced, with the above deviations showing statistical significance (P<0.05) compared with those for the 3-day and 7-day groups. No statistical difference in height linear deviation was observed among the groups.
CONCLUSIONS
The insufficient dimensional stability of 3D printed resin models can lead to changes in the relative position and angle of the replicas, thereby affecting the accuracy of the replicas in recreating the implant's position. Complete manufacturing of prosthesis is recommended within 7 days after the model is printed.
Printing, Three-Dimensional
;
Humans
;
Dental Implants
;
Models, Dental
;
Dental Impression Technique
;
Crowns
10.Fabrication and evaluation of dexmedetomidine hydrochloride microneedles based on 3D printing.
Yuanke YANG ; Xiaolu HAN ; Xianfu LI ; Xiaoxuan HONG ; Shanshan YANG ; Chunyan LIU ; Zengming WANG ; Aiping ZHENG
Chinese Journal of Biotechnology 2025;41(8):3214-3227
Compared with conventional transdermal drug delivery systems, dissolving microneedles significantly enhance drug bioavailability by penetrating the stratum corneum barrier and achieving intradermal drug delivery. In order to improve the transdermal bioavailability of dexmedetomidine hydrochloride, in this study, a novel microneedle delivery system was developed for dexmedetomidine hydrochloride based on 3D printing combined with micro-molding. By systematically optimizing the microneedle geometrical parameters, array arrangement, and preparation process parameters, we determined the optimal ratio of drug-carrying matrix as 15% PVP (polyvinyl pyrrolidone) K90. The microneedles exhibited significant drug loading gradients, with mean content of (209.99±27.56) μg/patch, (405.31±30.31) μg/patch, and (621.61±34.43) μg/patch. They showed a regular pyramidal structure under SEM and handheld electron microscopy, and their mechanical strength allowed effective penetration into the stratum corneum. The surface contact angles were all < 90°, indicating excellent hydrophilicity. The microneedles dissolved completely within 10 min after skin insertion, achieving a cumulative release rate of 90% (Higuchi model, r=0.996) during 2 hours of in vitro transdermal permeation. The cytotoxicity test and hemolysis test verified good biocompatibility. Pharmacodynamic evaluation showed that the microneedle group demonstrated pain-relieving effect within 15 min, with the pain threshold at the time point of 60 min being 3 times that in the transdermal cream group. The microneedle system developed in this study not only offers an efficient drug delivery option for patients but also establishes an innovative platform for rapid percutaneous delivery of hydrophilic drugs, demonstrating significant potential in perioperative pain management.
Dexmedetomidine/pharmacokinetics*
;
Printing, Three-Dimensional
;
Needles
;
Drug Delivery Systems/methods*
;
Administration, Cutaneous
;
Animals
;
Microinjections/instrumentation*
;
Skin Absorption
;
Skin/metabolism*


Result Analysis
Print
Save
E-mail