1.Three-dimensional finite element feature analysis of the mandible and morphology and position of temporomandibular joint in patients with unilateral and bilateral molar scissor bite.
Tianhao CHU ; Xueying ZHANG ; Haocheng WANG ; Haojie MA ; Yuanyuan LIU
West China Journal of Stomatology 2025;43(1):114-125
OBJECTIVES:
The objective of this study is to measuring the morphology and position of bilateral temporomandibular joints in patients with unilateral and bilateral molar scissor bite and simulating the deformation of the mandible during occlusion, in order to provide thesis for the diagnosis of temporomandibular joint disease in patients with unilateral and bilateral molar scissor bite.
METHODS:
This study was a retrospective study. A total of 10 patients with unilateral molar scissor bite (the unilateral molar scissor bite group) and 10 patients with bilateral molar scissor bite (the bilateral molar scissor bite group) were selected as the experimental group, and 20 adult patients with classⅠ of angle classification of similar ages were selected as the control group. All patients underwent cone beam computed tomography scans, by measuring the width of the fossa, height of the fossa, articular eminence inclination, long axis of the condyle, minor axis of the condyle, horizontal angle of the condyle and the space of the temporomandibular joint, compare temporomandibular joint morphology and position. The three-dimensional finite element analysis of the mandible morphology was carried out to evaluate the force and deformation of the mandible by using software to simulate the occlusion of the patients. It was further explored the relationship between the force of the mandible morphology and the possible temporomandibular joint disorder symptoms of the patients.
RESULTS:
Intergroup comparisons for the unilateral molar scissor bite group and left sides of the other groups revealed that the superior articular space in the group with unilateral molar scissor bite was shorter than that in the control group (P<0.05); the long axis of the condyle in the unilateral and bilateral molar scissor bite group were both shorter than that of the control group (P<0.05); among which the unilateral group was larger than the bilateral group, and the minor axis of the condyle in bilateral molar scissor bite group was smaller than in the control group (P<0.05), and the unilateral and bilateral condylar groups were larger than the control group (P<0.05); and the condylar horizontal angle in the unilateral and bilateral groups were larger than that in the control group (P<0.05). The normal sides of the unilateral molar scissor bite group and right sides of the other groups had smaller superior articular space than the control group (P<0.05); and the condylar long-axis in bilateral group was smaller than the control group (P<0.05); and the normal side of the condylar short-axis unilateral group was larger than that of the bilateral condylar group. Three-dimensional finite element analysis: the condyle of patients with molar scissor bite was a concentrated area of deformation during the bite of the mandible, when the first molar occlusion of the scissors bite side was simulated, the maximum deformation was located in the condyle in the X-axis and Z-axis directions. The amount of deformation was greater than that of the scissor bite side in the X-axis direction, while in the Z-axis direction, the normal side was greater than the scissor bite side. The maximum sites of local deformation in the X-axis direction were located in anterior and posterior the transverse crest of scissor bite side, and the minimum sites of local deformation was at 1/3 of the anterior slope of the inner pole of the normal side, the maximum local deformation sites in the Z-axis direction were located in the outer pole and below the outer pole of the normal side. The X-axis deformation value was the largest in the molars occlusion on the normal side, the Y-axis deformation value was in the premolars occlusion on the normal side, and the Z-axis deformation value was the largest in the centric occlusion, the deformation value of the condyle was not most significant in molar scissor bite.
CONCLUSIONS
Unilateral and bilateral molar scissor bite resulting in a short condyle morphology, and the bilateral group had a shorter condylar morphology than the unilateral group. The condyle of the patient with molar scissor bite is a concentrated area of poor occlusal deformation, and the largest sites of deformation are distributed near the transverse ridge of the inner and outer poles of the condyle. Different occlusion conditions have an effect on condylar deformation values, but do not indicate whether there is a clear association between them.
Humans
;
Finite Element Analysis
;
Retrospective Studies
;
Temporomandibular Joint/pathology*
;
Cone-Beam Computed Tomography
;
Mandible/pathology*
;
Imaging, Three-Dimensional
;
Adult
;
Temporomandibular Joint Disorders/diagnostic imaging*
;
Mandibular Condyle/diagnostic imaging*
;
Female
;
Male
;
Molar
2.Clinical analysis of changes in the position of the condyle and temporomandibular joint after repair of mandibular defects.
Shensui LI ; Xudong TIAN ; Yadong WU ; Weili WANG ; Zhenglong TANG
West China Journal of Stomatology 2025;43(3):422-430
OBJECTIVES:
This retrospective study aimed to investigate factors influencing positional changes of the condyle and temporomandibular joint (TMJ) following mandibular defect reconstruction with bone flaps, and to evaluate the biomechanical impacts of flap reconstruction on condylar positioning, thereby providing evidence for optimizing surgical protocols and TMJ functional rehabilitation.
METHODS:
A retrospective study was conducted on 90 patients undergoing mandibular segmental resection with immediate bone flap reconstruction at Guizhou Medical University Affiliated Stomatological Hospital (June 2019 to May 2024). After strict screening, 50 cases with complete data were analyzed. Clinical parameters (defect size, location, reconstruction method) and craniofacial CT scans at four timepoints [preoperative (T0), 7-10 days (T1), 3 months (T2), and 6 months (T3) postoperatively] were collected. Mimics 20 software facilitated 3D reconstruction for measuring TMJ anterior/posterior/superior joint spaces (Kamelchuk method) and calculating condylar position via the Pullinger index [Ln (posterior/anterior space)]. Vitral and Krisjane methods quantified mandibular linear parameters (ramus length, condylar pole distances to the sagittal plane, angulation) and glenoid fossa morphology. Statistical analyses were performed using SPSS 21.0.
RESULTS:
Mandibular defect size and location were significant factors influencing postoperative condylar position changes (P<0.05). Compared to preoperative measurements, postoperative condylar anterior, posterior, and superior joint spaces were significantly increased (P<0.001). The most pronounced anterior condylar displacement occurred within 7-10 days postoperatively (P<0.05). In patients with condyle resection, postoperative joint space and angle changes were significant; in patients with condyle preservation, only superior and anterior joint space changes were statistically significant (P<0.05). Additionally, from T1 to T2, the changes in condylar medial-lateral distance, superior joint space, and anterior joint space were negatively correlated with the preoperative condylar position. Compared with preoperative,in the T0-T1 period, condylar medial-lateral distance, posterior joint space, and articular tubercle angle changes were significantly negatively correlated with time (P<0.05). Notably, the angle between the condylar long axis and the coronal axis showed a sustained negative trend from T1 to T3 (P<0.05).
CONCLUSIONS
Condylar position changes after mandibular defect repair with bone flap reconstruction are associated with the size and location of the defect. Additionally, adaptive remodeling of the temporomandibular joint (TMJ) joint space occurs postoperatively. The phenomenon of anterior displacement of the condyle in the early postoperative period (7-10 days) shows a trend of reduction with prolonged follow-up time, and further sample size research is needed.
Humans
;
Retrospective Studies
;
Temporomandibular Joint/surgery*
;
Mandibular Condyle/surgery*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Mandibular Reconstruction/methods*
;
Mandible/surgery*
;
Surgical Flaps
;
Tomography, X-Ray Computed
;
Young Adult
;
Biomechanical Phenomena
;
Aged
;
Adolescent
;
Imaging, Three-Dimensional
3.Digital design and manufacturing method of double constrained split guide for orthodontic miniscrew implantation.
Xin DU ; Aonan WEN ; Zixiang GAO ; Zhihua LI ; Sheng ZHANG ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(4):603-612
This study explored a novel digital design and fabrication method for a double constrained split orthodontic miniscrew guide to improve the accuracy and safety of clinical miniscrew implantation and reduce related complications. A patient requiring miniscrew implantation was selected, and data were acquired using cone beam computed tomography (CBCT) and intraoral optical scanning. For the construction of a double constrained split guide including a screw-hole guide and an insertion rod guide, different types of software such as Mimics 24.0, Geomagic wrap 2021, and Materialise magics 21.0 were utilized for 3D reconstruction, model integration, and guide design. The guide was then fabricated via laser metal 3D printing. Model and intraoral try-in results demonstrated that the guide fitted well and was stable. Postoperative CBCT verified that the final miniscrew implantation site was consistent with the preoperative design, and no related complications occurred. This double constrained split orthodontic miniscrew guide provides a precise and safe digital solution for clinical miniscrew implantation.
Humans
;
Bone Screws
;
Cone-Beam Computed Tomography
;
Printing, Three-Dimensional
;
Orthodontic Anchorage Procedures/instrumentation*
;
Imaging, Three-Dimensional
;
Computer-Aided Design
4.Comparative study on the accuracy of extraoral scanning versus intraoral scanning in digital impressions for implant restoration in edentulous jaws.
Yongtao YANG ; Xin LI ; Xiangyi SHANG ; Shenyao SHAN ; Wenbo LI ; Qingzhao QIN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(6):771-779
OBJECTIVES:
To evaluate the accuracy of a self-developed extraoral scanning system based on four-camera stereophotogrammetric technology in the acquisition of three-dimensional positional information on dental implants and conduct a comparative study involving an intraoral scanning system.
METHODS:
With the use of an in vitro edentulous jaw model with implants, extraoral (experimental group) and intraoral (control group) scanning systems were employed to obtain STL (Standard Tessellation Language) datasets containing three-dimensional morphological and positional information on scan bodies. In addition, a dental model scanner was used to obtain reference data. The three-dimensional morphological, linear, and angular deviations between groups and reference data were analyzed using Geomagic Wrap 2021 software to compare trueness and precision.
RESULTS:
The extraoral scanning system demonstrated superior trueness in three-dimensional morphological, linear, and angular deviations compared with the intraoral scanning system, with statistically significant differences (P<0.001). The extraoral scanning system also showed a higher precision in three-dimensional morphological deviation (P<0.001). As the number of implants increased, the extraoral scanning system exhibited increased three-dimensional morphological and linear deviations (P<0.001) but maintained a stable angular deviation. The intraoral scanning system displayed significant increases in three-dimensional morphological, linear, and angular deviations with the increase in the number of implants (P<0.05).
CONCLUSIONS
The stereophotogrammetry-based extraoral scanning system outperforms intraoral scanning system in terms of the accuracy for multi-unit implant positioning and provides a novel approach for attaining a fully digital workflow for implant rehabilitation in edentulous jaws.
Jaw, Edentulous
;
Humans
;
Dental Impression Technique
;
Dental Implants
;
Imaging, Three-Dimensional/methods*
;
Photogrammetry/methods*
;
Models, Dental
5.Multi-modal cross-scale imaging technologies and their applications in plant network analysis.
Yining XIE ; Yuchen KOU ; Yanhui YUAN ; Jinbo SHEN ; Xiaohong ZHUANG ; Jinxing LIN ; Xi ZHANG
Chinese Journal of Biotechnology 2025;41(7):2559-2578
A complete plant body consists of elements on different scales, including microscopic molecules, mesoscopic multicellular structures, and macroscopic tissues and organs, which are interconnected to form complex biological networks. The growth and development of plants involve the regulation of elements on different scales and their biological networks, which requires the coordinated operation of multiple molecules, cells, tissues, and organs. It is difficult to reveal the essence of multi-level life activities by a single method or technology. In recent years, the development of various novel imaging technologies has provided new approaches for revealing the complex life activities in plants. Using multi-modal imaging technologies to study the cross-scale network connections of plants from the microscopic, mesoscopic, and macroscopic levels is crucial for understanding the complex internal connections behind biological functions. This paper first summarizes multi-modal cross-scale imaging technologies, three-dimensional reconstruction, and image processing methods, outlines the basic framework of cross-scale network connection properties, and then summarizes the applications of multi-modal imaging technologies in elucidating plant multi-scale networks. Finally, this review systematically integrates the combined analysis of cross-scale 3D spatial structural data and single-cell omics, laying a theoretical foundation for the innovation of novel plant imaging technologies. Furthermore, it provides a new research paradigm for in-depth exploration of the interaction mechanisms among cross-scale elements and the principles of biological network connectivity in plant life activities.
Plants/metabolism*
;
Imaging, Three-Dimensional/methods*
;
Image Processing, Computer-Assisted/methods*
;
Multimodal Imaging/methods*
;
Plant Physiological Phenomena
6.Thermal Ablation of Pulmonary Nodules by Electromagnetic Navigation Bronchoscopy Combined With Real-Time CT-Based 3D Fusion Navigation:Report of One Case.
Yuan XU ; Qun LIU ; Chao GUO ; Yi-Bo WANG ; Xiao-Fang WU ; Chen-Xi MA ; Gui-Ge WANG ; Qian-Shu LIU ; Nai-Xin LIANG ; Shan-Qing LI
Acta Academiae Medicinae Sinicae 2025;47(1):137-141
A nodule in the right middle lobe of the lung was treated by a combination of cone-beam CT,three-dimensional registration for fusion imaging,and electromagnetic navigation bronchoscopy-guided thermal ablation.The procedure lasted for 90 min,with no significant bleeding observed under the bronchoscope.The total radiation dose during the operation was 384 mGy.The patient recovered well postoperatively,with only a small amount of blood in the sputum and no pneumothorax or other complications.A follow-up chest CT on the first day post operation showed that the ablation area completely covered the lesion,and the patient was discharged successfully.
Humans
;
Bronchoscopy/methods*
;
Catheter Ablation/methods*
;
Cone-Beam Computed Tomography
;
Electromagnetic Phenomena
;
Imaging, Three-Dimensional
;
Lung Neoplasms/diagnostic imaging*
;
Tomography, X-Ray Computed
7.Three-dimensional human-robot mechanics modeling for dual-arm nursing-care robot transfer based on individualized musculoskeletal multibody dynamics.
Zhiqiang YANG ; Funing HOU ; Qiang LIN ; Jiexin XIE ; Hao LU ; Shijie GUO
Journal of Biomedical Engineering 2025;42(1):96-104
During transfer tasks, the dual-arm nursing-care robot require a human-robot mechanics model to determine the balance region to support the patient safely and stably. Previous studies utilized human-robot two-dimensional static equilibrium models, ignoring the human body volume and muscle torques, which decreased model accuracy and confined the robot ability to adjust the patient's posture in three-dimensional spatial. Therefore, this study proposes a three-dimensional spatial mechanics modeling method based on individualized human musculoskeletal multibody dynamics. Firstly, based on the mechanical features of dual-arm support, this study constructed a foundational three-dimensional human-robot mechanics model including body posture, contact position and body force. With the computed tomography data from subjects, a three-dimensional femur-pelvis-sacrum model was reconstructed, and the individualized musculoskeletal dynamics was analyzed using the ergonomics software, which derived the human joint forces and completed the mechanic model. Then, this study established a dual-arm robot transfer platform to conduct subject transfer experiments, showing that the constructed mechanics model possessed higher accuracy than previous methods. In summary, this study provides a three-dimensional human-robot mechanics model adapting to individual transfers, which has potential application in various scenarios such as nursing-care and rehabilitating robots.
Humans
;
Robotics
;
Biomechanical Phenomena
;
Posture
;
Imaging, Three-Dimensional
;
Nursing Care
8.Effectiveness of guide plate with mortise-tenon joint structure combined with off-axis fixation in treatment of Pauwels type Ⅲ femoral neck fractures.
Xuanye ZHU ; Lijuan CUI ; Leilei ZHANG ; Yudong JIA ; Yingjie ZHU ; Youwen LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):284-289
OBJECTIVE:
To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures.
METHODS:
A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups ( P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation.
RESULTS:
Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant ( P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group ( P<0.05), the incision was significantly longer ( P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups ( P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups ( P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups ( P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups ( P<0.05). There was no significant difference between the two plate groups ( P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups ( P>0.05).
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Plates
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Bone Screws
;
Adult
;
Aged
;
Treatment Outcome
;
Printing, Three-Dimensional
;
Operative Time
9.Imaging anatomy study on utilizing uncinate process "inflection point" as a landmark for anterior cervical spine decompression surgery.
Jianfeng JIANG ; Jun MA ; Maoyu YANG ; Yaozheng HAN ; Lintao SU ; Changyu LEI ; Chenguang GE ; Hui KANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):332-340
OBJECTIVE:
To explore the anatomical parameters of the cervical uncinate process "inflection point" through cervical CT angiography (CTA) and MRI measurements, offering a reliable and safe anatomical landmark for anterior cervical decompression surgery.
METHODS:
A retrospective analysis was conducted on the cervical CTA and MRI imaging data of normal adults who met the selection criteria between January 2020 and January 2024. The CTA dataset included 326 cases, with 200 males and 126 females, aged 22-55 years (mean, 46.7 years). The MRI dataset included 300 cases, with 200 males and 100 females, aged 18-55 years (mean, 43.7 years). Based on the CTA data, three-dimensional models of C 3-C 7 were constructed, and the following measurements were obtained from the superior view: uncinate process "inflection point" to vertebral artery distance (UIVD), uncinate process tip to vertebral artery distance (UTVD), uncinate process "inflection point" to "inflection point" distance (UID), uncinate process long-axis to sagittal angle (ULSA), and uncinate process "inflection point" to transverse foramen-sagittal angle (UITSA). From the anterior view, the anterior uncinate process to sagittal angle (AUSA) was measured. From the posterior view, the posterior uncinate process to sagittal angle (PUSA) was measured. Based on the MRI data, uncinate process "inflection point" to dural sac distance (UIDD) and dural sac width (DSW) were measured. The trends in measurement parameters of C 3-C 7 were observed, and the differences in measurement parameters between genders and between the left and right sides of the same segment were compared, as well as the difference in UID and DSW within the same segment was compared.
RESULTS:
The measurement parameters from C 3 to C 7 in the CTA data showed a general increasing trend, with no significant difference between the left and right sides within the same segment ( P>0.05). The UIVD, UTVD, and UID were greater in males than in females, with significant differences observed in the UIVD and UTVD at C 3 and C 6 and UID at C 3, C 6, and C 7 ( P<0.05). The MRI measured DSW showed a general increasing trend from C 3 to C 7, and the DSW at C 6 was greater in females than in males, with a significant difference ( P<0.05). The UIDD showed a gradual decreasing trend, with the smallest value at C 6. There was no significant difference between males and females or between the left and right sides within the same segment ( P>0.05). The UID was greater than the DSW at C 3-C 7, and the differences were significant ( P<0.05).
CONCLUSION
The uncinate process "inflection point" is a constant anatomical structure located at the anteromedial aspect of the uncinate process tip and laterally to the dural sac. It maintains a certain safe distance from the vertebral artery. As a decompression landmark in anterior cervical spine surgery, it not only ensures surgical safety but also guarantees complete decompression.
Humans
;
Adult
;
Male
;
Female
;
Middle Aged
;
Retrospective Studies
;
Cervical Vertebrae/surgery*
;
Magnetic Resonance Imaging
;
Decompression, Surgical/methods*
;
Young Adult
;
Adolescent
;
Computed Tomography Angiography
;
Imaging, Three-Dimensional
;
Vertebral Artery/anatomy & histology*
;
Anatomic Landmarks/diagnostic imaging*
10.Digital three-dimensional assisted unilateral biportal endoscopy in treatment of highly isolated lumbar disc herniation with translaminar approach.
Weiliang SU ; Suni LU ; Dong LIU ; Jianqiang XING ; Peng HU ; Yongfeng DOU ; Xiaopeng GENG ; Dawei WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):346-353
OBJECTIVE:
To investigate the effectiveness of digital three-dimensional (3D) assisted unilateral biportal endoscopy (UBE) in the treatment of highly isolated lumbar disc herniation (LDH) with translaminar approach.
METHODS:
The clinical data of 59 patients who met the selection criteria and underwent UBE treatment due to highly isolated LDH between January 2022 and December 2023 were retrospectively analyzed. Among them, 25 cases were treated with digital 3D assisted translaminar approach (observation group) and 34 cases were treated with interlaminar approach (control group). There was no significant difference in gender, age, disease duration, surgical segment, and preoperative visual analogue scale (VAS) score and Oswestry disability index (ODI) between the two groups ( P>0.05). The operation time, intraoperative blood loss, and lateral articular surface preservation rate were recorded and compared between the two groups. VAS score and ODI were used to evaluate the improvements of pain and function before operation and at 3 and 6 months after operation. The modified MacNab criteria was used to evaluate the effectiveness at last follow-up.
RESULTS:
One patient in the control group had dural tear, and the other patients had no nerve injury, infection, dural tear, or other related complications. There was no significant difference in operation time and intraoperative blood loss between the two groups ( P>0.05). Patients in both groups were followed up 6-13 months, with an average of 8.3 months. The lateral articular surface preservation rate in the observation group was significantly higher than that in the control group ( P<0.05). Three patients in the observation group and 2 patients in the control group had calf muscle venous thrombosis, which was cured after anticoagulant treatment with rivaroxaban and delayed exercise time. There was no recurrence or second operation during the follow-up period. The VAS score and ODI of the two groups at 3 and 6 months after operation significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two groups at each time point after operation ( P>0.05). At last follow-up, the effectiveness was evaluated according to the modified MacNab criteria, and there was no significant difference in the evaluation grade and excellent and good rate between the two groups ( P>0.05).
CONCLUTION
UBE via translaminar approach is safe and effective for the treatment of highly isolated LDH, which is beneficial to protect the facet joint, maintain spinal stability, and reduce soft tissue injury. With the assistance of digital 3D technique, preoperative planning can be performed accurately.
Humans
;
Intervertebral Disc Displacement/diagnostic imaging*
;
Lumbar Vertebrae/diagnostic imaging*
;
Male
;
Retrospective Studies
;
Female
;
Endoscopy/methods*
;
Treatment Outcome
;
Middle Aged
;
Adult
;
Imaging, Three-Dimensional
;
Operative Time
;
Pain Measurement

Result Analysis