1.Three-dimensional finite element analysis of digital wire loop space maintainers for missing deciduous teeth.
Lijuan MA ; Yonghui TENG ; Yong WANG ; Yijiao ZHAO ; Xinyue ZHANG ; Qingzhao QIN ; Dong YIN
Journal of Peking University(Health Sciences) 2025;57(2):376-383
OBJECTIVE:
To establish a three-dimensional finite element model of a digital wire loop space maintainer for the mandible and primary tooth loss, in order to investigate the stress, deformation, and shear force experienced by patients with the loss of the second primary molar when wearing the wire loop space maintainer.
METHODS:
Cone beam computed tomography (CBCT) scans were performed on the patients to create a digital model of the mandible with the absence of the second primary molar using Mimics 21.0 software. A digital model integrating the crown's retention and the wire loop structure of the full crown and ring wire loop space maintainer was constructed using pediatric space maintainer design software, utilizing three different materials: cobalt-chromium alloy, polyether ether ketone (PEEK), and titanium alloy. In ANSYS Work Beach 2023 R2 software, vertical loads of 70 N, tilted 45° along the long axis of the tooth loads of 70 N, and a 10 N load on the surface of the wire loop were applied to the occlusal surfaces of models 46 and 84, simulating centric and lateral occlusions during chewing with the wire loop space maintainer in place. The stress states of the wire loop space maintainer and supporting teeth were analyzed.
RESULTS:
Under various loading conditions, the maximum principal stress of the ring wire loop space maintainer was significantly lower than that of the full crown. Stress contour maps indicated that the peak of the maximum principal stress occurred at the junction of the wire loop and crown structure, indicating that this area was more susceptible to fracture. The ring wire loop space maintainer made from PEEK material exhibited the lowest maximum shear stress on the internal organizational surfaces, with equivalent stresses of 23.18 MPa and 36.35 MPa for models 46 and 84, respectively. Stress contour maps demonstrated that the maximum stress on tooth 46 was located at its mesial, while the maximum stress on tooth 84 was situated near the root area on its distal, in contact with the wire loop space maintainer.
CONCLUSION
In cases of second primary molar loss, wearing the digital ring wire loop space maintainer can effectively distribute stress, and the ring wire loop space maintainer made from PEEK material reduces the stress experienced by supporting teeth to some extent, demonstrating its superiority in clinical application.
Finite Element Analysis
;
Humans
;
Tooth, Deciduous
;
Cone-Beam Computed Tomography
;
Space Maintenance, Orthodontic/methods*
;
Imaging, Three-Dimensional
;
Orthodontic Wires
;
Dental Stress Analysis
;
Mandible
;
Stress, Mechanical
2.Finite Element Simulation Analysis of a Nickel-Titanium Alloy Patent Foramen Ovale Occluder.
Chinese Journal of Medical Instrumentation 2025;49(2):119-124
In this paper, a preliminary stress/strain analysis of the design structure of a nickel-titanium alloy patent foramen ovale occluder is conducted with the finite element simulation analysis method. In the analysis, solid structure modeling is carried out on three different specifications of domestic patent foramen ovale occluders. Referring to the test method of fatigue performance in inspection standard YY/T 1553-2017, an initial installation deformation is applied to the model, and then the fatigue displacement of 2 mm is applied to the sample to make the model fatigue deformation. The fatigue safety factors of each type of occluder are obtained by strain simulation analysis. The results indicate that the minimum fatigue safety factors of the three specifications of domestic patent foramen ovale occluders are 2.09, 2.35 and 2.06 respectively, which all meet the design of fatigue safety factor greater than 1. Among them, 1818 and 3030 specifications of patent foramen ovale occluders have close values in minimum fatigue safety factors, and both are lower than that of 1825 model. Therefore, it is recommended to carry out physical fatigue tests on both 1818 and 3030 specifications to further verify the fatigue performance of the products.
Finite Element Analysis
;
Titanium
;
Nickel
;
Alloys
;
Foramen Ovale, Patent
;
Materials Testing
;
Septal Occluder Device
;
Stress, Mechanical
3.A Novel Coronary Knobby Scoring Balloon and Biomechanical Study in Intravascular Dilation.
Feng GUO ; Junmin GUO ; Jipeng CHEN ; Xuemei DUAN ; Wenkang ZHANG
Chinese Journal of Medical Instrumentation 2025;49(3):269-275
This study investigated a novel coronary knobby scoring balloon through finite element analysis (FEA) and in vitro anti-slippage testing, evaluating its dilation process under various vascular conditions and comparing it with other balloons. The FEA results indicated that in the cases of healthy artery and diseased artery with different stenosis rates, the stress on the vessels caused by the knobby scoring balloon was significantly smaller than that of the scoring balloon, and was close to that of the plain balloon. In vitro anti-slippage testing showed that the slippage distance of a plain balloon was 0.11±0.06 mm, and there was no slippage for knobby scoring balloon under nominal pressure. Knobby scoring balloon can effectively expand calcified lesion while providing anti-slippage function, and has a lower risk of vascular injury.
Finite Element Analysis
;
Humans
;
Angioplasty, Balloon, Coronary/instrumentation*
;
Equipment Design
;
Biomechanical Phenomena
;
Coronary Vessels
4.Biomechanical analysis of a novel bridging plate for treating Rockwood III acromioclavicular joint dislocation.
Yancai CHEN ; Gaofeng ZHANG ; Shubo LI ; Nianxiang LUO ; Yi ZHANG
Journal of Southern Medical University 2025;45(5):1103-1112
OBJECTIVES:
To assess the biomechanical performance of a novel bridging plate for treating Rockwood III acromioclavicular joint dislocation.
METHODS:
A novel bridging plate structure was designed based on CT data from a patient with Rockwood type III acromioclavicular joint dislocation, and a finite element model of the bridging plate-acromioclavicular joint interaction was constructed. The stress and deformation characteristics and biomechanical compatibility of the plate under post-reduction, normal loading, and impact loading conditions were analyzed to evaluate its fixation mechanism and clinical advantages.
RESULTS:
The stiffness of the bridging system was 27.78 N/mm, close to that of acromioclavicular joint ligaments (26.05 N/mm) and meeting the requirements for flexible deformation. Under normal loading, the maximum stress in the bridging system was 88.29 MPa to sustain physiological activities; under impact loading, the maximum stress reached 480 MPa, and the cable underwent plastic deformation to dissipate energy and effectively buffer local stress concentrations, thereby reducing the risk of rigid bone fractures. The high-stress regions in the bone primarily occurred at the edges of the C1-C4 screw holes. The maximum bone stress was 0.762 MPa under normal loading and 5.963 MPa under impact loading, accounting for 2.86% and 1.66% of the corresponding bolt stresses, respectively.
CONCLUSIONS
The novel bridging plate is better adapted to biomechanical characteristics of the acromioclavicular joint compared to traditional internal fixation. This fixation system provides sufficient stability while allowing physiological micromotion to facilitate postoperative rehabilitation. Significant flexible deformation can occur at the connection between the fixation ring and the cable, and brittle materials should not be used in this region. The issue of stress concentration at the C1-C4 screw holes requires special attention in its clinical application.
Acromioclavicular Joint/surgery*
;
Humans
;
Bone Plates
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Joint Dislocations/surgery*
;
Fracture Fixation, Internal/methods*
5.Three-dimensional finite element feature analysis of the mandible and morphology and position of temporomandibular joint in patients with unilateral and bilateral molar scissor bite.
Tianhao CHU ; Xueying ZHANG ; Haocheng WANG ; Haojie MA ; Yuanyuan LIU
West China Journal of Stomatology 2025;43(1):114-125
OBJECTIVES:
The objective of this study is to measuring the morphology and position of bilateral temporomandibular joints in patients with unilateral and bilateral molar scissor bite and simulating the deformation of the mandible during occlusion, in order to provide thesis for the diagnosis of temporomandibular joint disease in patients with unilateral and bilateral molar scissor bite.
METHODS:
This study was a retrospective study. A total of 10 patients with unilateral molar scissor bite (the unilateral molar scissor bite group) and 10 patients with bilateral molar scissor bite (the bilateral molar scissor bite group) were selected as the experimental group, and 20 adult patients with classⅠ of angle classification of similar ages were selected as the control group. All patients underwent cone beam computed tomography scans, by measuring the width of the fossa, height of the fossa, articular eminence inclination, long axis of the condyle, minor axis of the condyle, horizontal angle of the condyle and the space of the temporomandibular joint, compare temporomandibular joint morphology and position. The three-dimensional finite element analysis of the mandible morphology was carried out to evaluate the force and deformation of the mandible by using software to simulate the occlusion of the patients. It was further explored the relationship between the force of the mandible morphology and the possible temporomandibular joint disorder symptoms of the patients.
RESULTS:
Intergroup comparisons for the unilateral molar scissor bite group and left sides of the other groups revealed that the superior articular space in the group with unilateral molar scissor bite was shorter than that in the control group (P<0.05); the long axis of the condyle in the unilateral and bilateral molar scissor bite group were both shorter than that of the control group (P<0.05); among which the unilateral group was larger than the bilateral group, and the minor axis of the condyle in bilateral molar scissor bite group was smaller than in the control group (P<0.05), and the unilateral and bilateral condylar groups were larger than the control group (P<0.05); and the condylar horizontal angle in the unilateral and bilateral groups were larger than that in the control group (P<0.05). The normal sides of the unilateral molar scissor bite group and right sides of the other groups had smaller superior articular space than the control group (P<0.05); and the condylar long-axis in bilateral group was smaller than the control group (P<0.05); and the normal side of the condylar short-axis unilateral group was larger than that of the bilateral condylar group. Three-dimensional finite element analysis: the condyle of patients with molar scissor bite was a concentrated area of deformation during the bite of the mandible, when the first molar occlusion of the scissors bite side was simulated, the maximum deformation was located in the condyle in the X-axis and Z-axis directions. The amount of deformation was greater than that of the scissor bite side in the X-axis direction, while in the Z-axis direction, the normal side was greater than the scissor bite side. The maximum sites of local deformation in the X-axis direction were located in anterior and posterior the transverse crest of scissor bite side, and the minimum sites of local deformation was at 1/3 of the anterior slope of the inner pole of the normal side, the maximum local deformation sites in the Z-axis direction were located in the outer pole and below the outer pole of the normal side. The X-axis deformation value was the largest in the molars occlusion on the normal side, the Y-axis deformation value was in the premolars occlusion on the normal side, and the Z-axis deformation value was the largest in the centric occlusion, the deformation value of the condyle was not most significant in molar scissor bite.
CONCLUSIONS
Unilateral and bilateral molar scissor bite resulting in a short condyle morphology, and the bilateral group had a shorter condylar morphology than the unilateral group. The condyle of the patient with molar scissor bite is a concentrated area of poor occlusal deformation, and the largest sites of deformation are distributed near the transverse ridge of the inner and outer poles of the condyle. Different occlusion conditions have an effect on condylar deformation values, but do not indicate whether there is a clear association between them.
Humans
;
Finite Element Analysis
;
Retrospective Studies
;
Temporomandibular Joint/pathology*
;
Cone-Beam Computed Tomography
;
Mandible/pathology*
;
Imaging, Three-Dimensional
;
Adult
;
Temporomandibular Joint Disorders/diagnostic imaging*
;
Mandibular Condyle/diagnostic imaging*
;
Female
;
Male
;
Molar
6.Biomechanical analysis of three kinds of rigid internal fixation methods for condylar head fractures.
Junhui SUN ; Duoduo LAN ; Dong WANG ; Yao XU ; Zeyu WANG ; Chenchen ZHANG ; Kai ZHANG ; Tao XU
West China Journal of Stomatology 2025;43(1):126-132
OBJECTIVES:
This study aims to analyze the biomechanics of three kinds of rigid internal fixation methods for condylar head fractures.
METHODS:
A three dimensional finite element model of the normal mandible was constructed. It was then used to prepare condylar head fracture finite element model and three kinds of rigid internal fixation finite element model (unilateral tension screw, bilateral tension screw, tension screw+titanium plate). The mechanical characteristics and changes of the mandible condyle under the same mechanical conditions were compared among the three different rigid internal fixation methods.
RESULTS:
The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of unilateral tension screw were 71.03 MPa and 4.72 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 78.45 MPa and 4.50 mm, respectively. The maximum stress of fracture suture was 3.27 MPa. The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of bilateral tension screw were 70.52 MPa and 4.00 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 72.49 MPa and 3.85 mm, respectively. The maximum stress of fracture suture was 2.33 MPa. The maximum equivalent stress and maximum displacement of the non-free end of condyle under the rigid internal fixation method of tension screw+titanium plate were 67.26 MPa and 2.66 mm, respectively. The maximum equivalent stress and maximum displacement of the free end of condyle were 69.66 MPa and 2.50 mm, respectively. The maximum stress of fracture suture was 2.18 MPa.
CONCLUSIONS
The tension screw+titanium plate rigid internal fixation method is the most conducive to biomechanical distribution for condylar head fractures.
Fracture Fixation, Internal/instrumentation*
;
Mandibular Condyle/surgery*
;
Biomechanical Phenomena
;
Bone Screws
;
Finite Element Analysis
;
Humans
;
Mandibular Fractures/surgery*
;
Bone Plates
;
Titanium
;
Stress, Mechanical
7.Biomechanical effects of medial and lateral translation deviations of femoral components in unicompartmental knee arthroplasty on tibial prosthesis fixation.
Jingting XU ; Jing ZHANG ; Bing ZHANG ; Wen CUI ; Weijie ZHANG ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(1):105-112
Prosthesis loosening is the leading cause of postoperative revision in unicompartmental knee arthroplasty (UKA). The deviation of medial and lateral translational installation of the prosthesis during surgery is a common clinical phenomenon and an important factor in increasing the risk of prosthesis loosening. This study established a UKA finite element model and a bone-prosthesis fixation interface micromotion prediction model. The predicted medial contact force and joint motion of the knee joint from a patient-specific lower extremity musculoskeletal multibody dynamics model of UKA were used as boundary conditions. The effects of 9 femoral component medial and lateral translational installation deviations on the Von Mises stress of the proximal tibia, the contact stress, and the micro-motion of the bone prosthesis fixation interface were quantitatively studied. It was found that compared with the neutral position (a/A of 0.492), the lateral translational deviation of the femoral component significantly increased the tibial Von Mises stress and the bone-prosthesis fixation interface contact stress. The maximum Von Mises stress and the maximum contact stress of the fixation interface increased by 14.08% and 143.15%, respectively, when a/A was 0.361. The medial translational deviation of the femoral component significantly increased the bone-prosthesis fixation interface micro-motion. The maximum value of micromotion under the conditions of femoral neutral and medial translation deviation was in the range of 20-50 μm, which is suitable for osseointegration. Therefore, based on considerations such as the micromotion range suitable for osseointegration reported in the literature, the risk of reducing prosthesis loosening, and factors that may induce pain, it is recommended that clinicians control the mounting position of the femoral component during surgery within the safe range of 0-4 mm medial translation deviation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Knee Prosthesis
;
Tibia/surgery*
;
Femur/surgery*
;
Stress, Mechanical
;
Prosthesis Failure
;
Knee Joint/surgery*
;
Prosthesis Design
8.Quantitative analysis of transcranial temporal interference stimulation in rodents: A simulation study on electrode configurations.
Xiaoxi LIU ; Hongli YU ; Fushuai GOU ; Boai DU ; Pengyi LU ; Chunfang WANG
Journal of Biomedical Engineering 2025;42(2):280-287
Transcranial temporal interference stimulation (tTIS) is a novel non-invasive transcranial electrical stimulation technique that achieves deep brain stimulation through multiple electrodes applying electric fields of different frequencies. Current studies on the mechanism of tTIS effects are primarily based on rodents, but experimental outcomes are often significantly influenced by electrode configurations. To enhance the performance of tTIS within the limited cranial space of rodents, we proposed various electrode configurations for tTIS and conducted finite element simulations using a realistic mouse model. Results demonstrated that ventral-dorsal, four-channel bipolar, and two-channel configurations performed best in terms of focality, diffusion of activated brain regions, and scalp impact, respectively. Compared to traditional transcranial direct current stimulation (tDCS), these configurations improved by 94.83%, 50.59%, and 3 514.58% in the respective evaluation metrics. This study provides a reference for selecting electrode configurations in future tTIS research on rodents.
Animals
;
Transcranial Direct Current Stimulation/instrumentation*
;
Electrodes
;
Mice
;
Computer Simulation
;
Finite Element Analysis
;
Brain/physiology*
9.A simulation study of nerve fiber activation in the lumbar segment under kilohertz-frequency transcutaneously spinal cord stimulation.
Qi XU ; Xinru LI ; Zhixin LU ; Yongchao WU
Journal of Biomedical Engineering 2025;42(2):300-307
Clinical trials have demonstrated that kilohertz-frequency transcutaneous spinal cord stimulation (TSCS) can be used to facilitate the recovery of sensory-motor function for patients with spinal cord injury, whereas the neural mechanism of TSCS is still undetermined so that the choice of stimulation parameters is largely dependent on the clinical experience. In this paper, a finite element model of transcutaneous spinal cord stimulation was used to calculate the electric field distribution of human spinal cord segments T 12 to L 2, whereas the activation thresholds of spinal fibers were determined by using a double-cable neuron model. Then the variation of activation thresholds was obtained by varying the carrier waveform, the interphase delay, the modulating frequency, and the modulating pulse width. Compared with the sinusoidal carrier, the usage of square carrier could significantly reduce the activation threshold of dorsal root (DR) fibers. Moreover, the variation of activation thresholds was no more than 1 V due to the varied modulating frequency and decreases with the increased modulating pulse width. For a square carrier at 10 kHz modulated by rectangular pulse with the frequency of 50 Hz and the pulse width of 1 ms, the lowest activation thresholds of DR fibers and dorsal column fibers were 27.6 V and 55.8 V, respectively. An interphase delay of 5 μs was able to reduce the activation thresholds of the DR fibers to 20.1 V. The simulation results can lay a theoretical foundation on the selection of TSCS parameters in clinical trials.
Humans
;
Spinal Cord Stimulation/methods*
;
Nerve Fibers/physiology*
;
Finite Element Analysis
;
Spinal Cord/physiology*
;
Computer Simulation
;
Spinal Cord Injuries/physiopathology*
;
Lumbosacral Region
;
Lumbar Vertebrae
;
Transcutaneous Electric Nerve Stimulation/methods*
;
Models, Neurological
10.Biomechanical study on wing shaped titanium plate fixation of acetabular anterior column and posterior hemi-transverse fracture under multiple working conditions.
Jianwu ZHANG ; WURIKAIXI AIYITI ; Gang LYU ; MAIMAIAILI YUSHAN ; Zhiqiang MA ; Chao MA
Journal of Biomedical Engineering 2025;42(2):351-358
This article aims to compare and analyze the biomechanical differences between wing-shaped titanium plates and traditional titanium plates in fixing acetabular anterior column and posterior hemi-transverse (ACPHT) fracture under multiple working conditions using the finite element method. Firstly, four sets of internal fixation models for acetabular ACPHT fractures were established, and the hip joint stress under standing, sitting, forward extension, and abduction conditions was calculated through analysis software. Then, the stress of screws and titanium plates, as well as the stress and displacement of the fracture end face, were analyzed. Research has found that when using wing-shaped titanium plates to fix acetabular ACPHT fractures, the peak stress of screws decreases under all working conditions, while the peak stress of wing-shaped titanium plates decreases under standing and sitting conditions and increases under forward and outward extension conditions. The relative displacement and mean stress of the fracture end face decrease under all working conditions, but the values are higher under forward and outward extension conditions. Wing-shaped titanium plates can reduce the probability of screw fatigue failure when fixing acetabular ACPHT fractures and can bear greater loads under forward and outward extension conditions, improving the mechanical stability of the pelvis. Moreover, the stress on the fracture end surface is more conducive to stimulating fracture healing and promoting bone tissue growth. However, premature forward and outward extension rehabilitation exercises should not be performed.
Titanium
;
Bone Plates
;
Humans
;
Acetabulum/surgery*
;
Fracture Fixation, Internal/methods*
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Bone Screws
;
Fractures, Bone/surgery*
;
Stress, Mechanical
;
Working Conditions

Result Analysis