1.Development of a balloon sensor device for force-electrical coupling measurement of esophagus.
Peng RAN ; Ying ZHONG ; Yingbing LAI ; Lei LIU ; Yanhang ZHU ; Huantao ZHU
Journal of Biomedical Engineering 2025;42(3):610-619
To address the challenges of capturing micro-strains in detecting esophageal motility disorders and the limitations of existing high-resolution manometry and functional intraluminal imaging probes in directly measuring esophageal tissue electrical impedance, this study proposes a novel flexible balloon sensor structure that integrates a piezoelectric film assembly with a distributed impedance electrode array. Using the electrical analysis module in the finite element analysis (FEA) software, simulations of the forward problem for esophageal impedance detection were conducted to optimize the excitation source parameters, and a physical prototype was fabricated. Under a relative excitation mode with a voltage sensitivity of 2.059%, the voltage output characteristics of the impedance electrode array were analyzed during linear changes in the balloon filling volume. Based on the performance variation of the piezoelectric film assembly, 80% was selected as the optimal filling volume. Force-electric coupling tests were conducted on the balloon sensor using a pressure testing platform, revealing that both the piezoelectric film assembly inside the balloon and the impedance electrodes outside the balloon exhibited significant load differentiation characteristics as the force application point shifted. In summary, this balloon sensor facilitates the localization of force application while simultaneously analyzing esophageal tissue properties, offering a novel diagnostic approach and objective tool for esophageal disease detection.
Esophagus/physiology*
;
Electric Impedance
;
Humans
;
Finite Element Analysis
;
Manometry/methods*
;
Electrodes
;
Esophageal Motility Disorders/physiopathology*
;
Equipment Design
2.Mechanism of Banxia Houpo Decoction in Treating Gastroesophageal Reflux Disease: An Integrated Approach of Compound Analysis, Network Pharmacology and Empirical Verification.
Shun-Zhe SONG ; Jiang-Nan XIE ; Jing-Wen ZHANG ; Ai-Xia GONG
Chinese journal of integrative medicine 2025;31(10):889-898
OBJECTIVE:
To elucidate the mechanism of Banxia Houpo Decoction (BHD) in treating gastroesophageal reflux disease (GERD) by integrating and utilizing the compound analysis, network pharmacology, and empirical verification.
METHODS:
Ultra-high performance liquid chromatography-high resolution mass spectrometry (UPLC-HRMS) was utilized to identify the primary compounds in BHD. Network pharmacology was employed to retrieve target genes. A GERD rat model was developed and 32 SD rats were randomly divided into model, BHD-L (3 g/kg), BHD-H (6 g/kg), and mosapride (0.75 mg/kg) groups using a random number table, 8 rats in each group. Eight rats without the construction of a GERD model were selected as the blank group. Esophageal damage was evaluated through visualization and histopathology evaluation. 5-hydroxytryptamine (5-HT) levels in serum and lower esophageal sphincter (LES) were determined by ELISA. LES contractility was measured with a force transducer, and serotonin transporter (SERT) and 5-HT4R expressions in LES were assessed by RT-PCR, Western blot, and immunofluorescence staining, respectively.
RESULTS:
UPLC-HRMS analysis identified 37 absorption peaks and 157 compounds in BHD. Functional enrichment identified SERT as a significant target for LES contractility. Histopathological findings indicated less severe esophageal mucosal damage in the BHD-H group compared with the model group. Although serum 5-HT levels showed no significant difference, 5-HT concentration in LES tissue was notably higher in the BHD-H group (P<0.05). Within the range from 10-10 to 10-7 mmol/L, LES contractility in the BHD-H and mosapride groups was significantly increased (P<0.05). Within the range from 3 × 10-7 to 3 × 10-6 mmol/L 5-HT, LES contractility in the BHD-H group was increased (P<0.05). No significant difference was detected within the range from 10-5 to 10-4 mmol/L 5-HT. Notably, SERT expression in the BHD-H group assessed by RT-PCR, Western blot, and immunofluorescence staining were significantly lower than that in the model group (all P<0.01); while 5-HT4R expression remained unchanged.
CONCLUSION
BHD may increase LES contractility by inhibiting SERT expression in LES tissue.
Animals
;
Gastroesophageal Reflux/physiopathology*
;
Drugs, Chinese Herbal/chemistry*
;
Rats, Sprague-Dawley
;
Network Pharmacology
;
Male
;
Serotonin/metabolism*
;
Rats
;
Disease Models, Animal
;
Serotonin Plasma Membrane Transport Proteins/metabolism*
;
Esophagus/drug effects*
3.Regression analysis of preoperative chest radiographs to predict intraoperative location of esophageal foreign body (coin) in pediatric patients
Angelika Doreen M. Balite ; Fortuna Corazon A. Roldan
Philippine Journal of Otolaryngology Head and Neck Surgery 2024;39(2):21-25
Objectives:
To provide a guide to estimate the location of coins within the esophagus based on the pre-operative radiographic image among pediatric patients seen at the East Avenue Medical Center Department of Otorhinolaryngology – Head and Neck Surgery (ORL-HNS) between January 2018 and December 2020.
:
Methods
Design:
Retrospective Case Series
Setting:
Tertiary Government Training Hospital
Participants:
The records of 99 pediatric patients aged 6 months to 13 years who were diagnosed with esophageal foreign body (coin) impaction and underwent rigid esophagoscopy from January 2018 to December 2020 were retrospectively reviewed.
Results:
A predictive model was derived from the data using linear regression analysis. The model shows that we can predict the intraoperative location of coin within the esophagus if provided with the patient’s age and vertebral level of the coin on chest radiograph. Prediction values were reported for patients in three age categories (less than 3 years old, 3 to 7 years old, 8 to 13 years old), at 10 radiographic locations (C2, C4, C5, C6, C7, T1, T2, T3, T7, T8), except for these (C1, C3, T4-T6) because of lack of data. For example, the table predicts that a coin will be located 13 cm (or between 11.4cm to 14.8cm) from the central maxillary incisors (CMI) intraoperatively if the coin was located at level C6 vertebrae on chest radiograph, for patients less than 3 years old.
Conclusion
This study provides a novel guide that may serve as a practical tool for ENT surgeons to estimate the intraoperative location of coin foreign bodies in the esophagus of pediatric patients based on preoperative radiographic imaging.
Foreign Bodies
;
Foreign Bodies
;
Esophagus
;
Esophagoscopes
;
Esophagoscopic Surgery
;
Esophagoscopic Surgical Procedures
;
Esophagoscopy
4.Indications and complications prevention and management of phaseⅡ implantation of Provox Vega voice prosthesis after total laryngectomy.
Chun Ping WU ; Xiao Hui YUAN ; Duo ZHANG ; Ling CHEN ; Lei TAO
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(1):52-58
Objective: To explore the indications and management of common postoperative complications of phase II tracheoesophageal puncture (TEP) for Provox Vega voice prosthesis after total laryngectomy. Methods: The clinical data of 20 patients undergoing phase II TEP for Provox Vega voice prosthesis in our hospital between May 2021 and January 2022 were analyzed. Among them, there were 19 males and 1 female, aged from 37 to 76 years, with an average age of (60.0±8.4)years. The surgical indications and the prevention and treatment of common postoperative complications were summarized. Descriptive analysis was used in this research. Results: The basic surgical indications were as following: after total laryngectomy, there was no stenosis of the stoma and esophagus entrance, no scar constitution, no mouth opening restriction, no stiffness and backward restraint of the neck after radiotherapy, and more than half a year apart surgery or radiotherapy. Among the 20 patients, 18 underwent implantation successfuly, 1 failed in the operation, and for 1 patient, the prosthesis was removed due to bleeding 1 week after implantation. The common postoperative complications included TEP fistula infection (2 cases), the TEP fistula bleeding(1 case), deep neck (prevertebral) abscess (1 case), granulation at the inner side of the TEP fistula (1 case), invagination of the prosthesis (2 cases) and leakage around the prosthesis (2 cases). All patients were cured with different interventions. Conclusions: The Provox Vega voice prosthesis is generally safe for phase Ⅱ implantatione, but implantation indications need to be established. Common postoperative complications can be solved through preventive and remedial interventions.
Male
;
Humans
;
Female
;
Larynx, Artificial/adverse effects*
;
Laryngectomy/adverse effects*
;
Prosthesis Implantation/adverse effects*
;
Esophagus/surgery*
;
Postoperative Complications/etiology*
;
Prosthesis Design
7.Research progress of button battery ingestion in children.
Feng Zhen ZHANG ; Qing Chuan DUAN ; Gui Xiang WANG ; Jing ZHAO ; Hua WANG ; Hong Bin LI ; Xin NI ; Jie ZHANG
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(4):394-398
Child
;
Humans
;
Infant
;
Esophagus
;
Electric Power Supplies
;
Eating
;
Foreign Bodies
9.Perforation of the esophagus: an overlooked cause of chest pain as a complication of esophageal foreign bodies.
Chengfan QIN ; Yunmei YANG ; Yuanqiang LU
Journal of Zhejiang University. Science. B 2023;24(5):455-457
Chest pain is one of the most common complaints in the emergency department. Diseases of the heart, aorta, lungs, esophagus, stomach, mediastinum, pleura, and abdominal viscera can all cause chest discomfort (Gulati et al., 2021; Jiao et al., 2021; Lu et al., 2022). Clinicians in the emergency department are expected to immediately recognize life-threatening chest pain (Jiao et al., 2021). Delayed diagnosis further increases the risk of complications and mortality (Liu et al., 2021). In this case, we present an elderly Chinese female who had a history of myocardial infarction two years previously, with chest pain eventually found to be caused by ingestion of a duck bone.
Humans
;
Female
;
Aged
;
Esophagus
;
Foreign Bodies/diagnosis*
;
Chest Pain/complications*
;
Emergency Service, Hospital
;
Heart
10.Application of novel non-endoscopic device in the screening and early diagnosis of esophageal cancer.
Zhi Yuan FAN ; Ru CHEN ; Wen qiang WEI
Chinese Journal of Oncology 2023;45(8):637-641
Esophageal cancer (EC) is a dreadful disease with a poor prognosis and poses heavy health burden worldwide. Developing effective methods to identify high-risk individuals is urgently needed for preliminary screening before endoscopy. The novel non-endoscopic device has the potential advantages of low cost, simple operation, and minimal invasiveness. Approximately 90% of participants can swallow the device successfully with high safety profiles, and sufficient esophageal exfoliated cells can be collected for cytological examination and biomarker detection. Cytological examination based on the device combined with trefoil factor 3 (TFF3) protein or DNA methylation examinations could effectively screen Barrett's esophagus-associated dysplasia and early esophageal adenocarcinoma, but large prospective studies are needed to further validate the diagnostic value of this device to improve the quality of evidence. Although the device-based cytological examination in combination with biomarker detection holds promise in the early screening of esophageal squamous dysplasia and early esophageal squamous cell carcinoma, related research is still in its infancy, and there is still a lack of sufficient evidence for population screening in China. Active research into the application of this novel non-endoscopic device in EC screening and early diagnosis is of great significance for optimizing EC screening strategies and improving the early diagnosis of EC.
Humans
;
Esophageal Neoplasms/pathology*
;
Early Detection of Cancer
;
Esophageal Squamous Cell Carcinoma
;
Barrett Esophagus/pathology*
;
Biomarkers/analysis*
;
Esophagoscopy


Result Analysis
Print
Save
E-mail