1.Advances in electrochemically active biofilm of Shewanella oneidensis MR-1.
Chinese Journal of Biotechnology 2023;39(3):881-897
Facing the increasingly severe energy shortage and environmental pollution, electrocatalytic processes using electroactive microorganisms provide a new alternative for achieving environmental-friendly production. Because of its unique respiratory mode and electron transfer ability, Shewanella oneidensis MR-1 has been widely used in the fields of microbial fuel cell, bioelectrosynthesis of value-added chemicals, metal waste treatment and environmental remediation system. The electrochemically active biofilm of S. oneidensis MR-1 is an excellent carrier for transferring the electrons of the electroactive microorganisms. The formation of electrochemically active biofilm is a dynamic and complex process, which is affected by many factors, such as electrode materials, culture conditions, strains and their metabolism. The electrochemically active biofilm plays a very important role in enhancing bacterial environmental stress resistance, improving nutrient uptake and electron transfer efficiency. This paper reviewed the formation process, influencing factors and applications of S. oneidensis MR-1 biofilm in bio-energy, bioremediation and biosensing, with the aim to facilitate and expand its further application.
Bioelectric Energy Sources/microbiology*
;
Biofilms
;
Electrodes
;
Electron Transport
;
Shewanella/metabolism*
2.Simulation Results and Analysis of Electric Field Distribution in Myocardial Tissue under Circular Electrode Electric Pulse Ablation.
Wencai WANG ; Qunshan WANG ; Binfeng MO ; Jinhai NIU
Chinese Journal of Medical Instrumentation 2023;47(3):242-246
As a new energy source for atrial fibrillation ablation, electric pulse ablation has higher tissue selectivity and biosafety, so it has a great application prospect. At present, there is very limited research on multi-electrode simulated ablation of histological electrical pulse. In this study, a circular multi-electrode ablation model of pulmonary vein will be built on COMSOL5.5 platform for simulation research. The results show that when the voltage amplitude reaches about 900 V, it can make some positions achieve transmural ablation, and the depth of continuous ablation area formed can reach 3 mm when the voltage amplitude reaches 1 200 V. When the distance between catheter electrode and myocardial tissue is increased to 2 mm, a voltage of at least 2 000 V is required to make the depth of continuous ablation area reach 3 mm. Through the simulation of electric pulse ablation with ring electrode, the research results of this project can provide reference for the voltage selection in the clinical application of electric pulse ablation.
Humans
;
Heart Rate
;
Atrial Fibrillation/surgery*
;
Electrodes
;
Catheter Ablation
;
Electricity
3.Roadmap of Medical Device for Implanted Brain-computer Interface.
Tao SU ; Chunshan DENG ; Xiaojian LI
Chinese Journal of Medical Instrumentation 2023;47(3):304-308
Implanted brain-computer interface (iBCI) is a system that establishes a direct communication channel between human brain and computer or an external devices by implanted neural electrode. Because of the good functional extensibility, iBCI devices as a platform technology have the potential to bring benefit to people with nervous system disease and progress rapidly from fundamental neuroscience discoveries to translational applications and market access. In this report, the industrialization process of implanted neural regulation medical devices is reviewed, and the translational pathway of iBCI in clinical application is proposed. However, the Food and Drug Administration (FDA) regulations and guidances for iBCI were expounded as a breakthrough medical device. Furthermore, several iBCI products in the process of applying for medical device registration certificate were briefly introduced and compared recently. Due to the complexity of iBCI in clinical application, the translational applications and industrialization of iBCI as a medical device need the closely cooperation between regulatory departments, companies, universities, institutes and hospitals in the future.
Humans
;
Brain-Computer Interfaces
;
Brain/physiology*
;
Electrodes, Implanted
4.Chinese emergency expert consensus on bedside temporary cardiac pacing (2023).
EMERGENCY MEDICINE BRANCH OF CHINESE MEDICAL ASSOCIATION ; BEDSIDE TEMPORARY CARDIAC PACING CONSENSUS EMERGENCY EXPERT GROUP
Chinese Critical Care Medicine 2023;35(7):678-683
Temporary cardiac pacing is an essential technique in the diagnosis and treatment of arrhythmias. Due to its urgency, complexity, and uncertainty, it is necessary to develop an evidence-based emergency operation norms. Currently, there is no specific consensus guidelines at home or abroad. The Emergency Branch of Chinese Medical Association organized relevant experts to draft the Chinese emergency expert consensus on bedside temporary cardiac pacing (2023) to guide the operation and application of bedside cardiac pacing. The formulation of the consensus adopts the consensus meeting method and the evidentiary basis and recommendation grading of the Oxford Center for Evidence-based Medicine in the United States. A total of 13 recommendations were extracted from the discussion on the methods of bedside temporary cardiac pacing, the puncture site of transvenous temporary cardiac pacing, the selection of leads, the placement and placement of leads, pacemaker parameter settings, indications, complications and postoperative management. The recommended consensus includes the choice between transcutaneous and transvenous pacing, preferred venous access for temporary transvenous pacing, the target and best guidance method for implantation of bedside pacing electrodes, recommended default pacemaker settings, recommended indications for sinoatrial node dysfunction, atrioventricular block, acute myocardial infarction, cardiac arrest, ventricular and supraventricular arrhythmias. They also recommended ultrasound guidance and a shortened temporary pacing support time to reduce complications of temporary transvenous cardiac pacing, recommended bedrest, and anticoagulation after temporary transvenous pacing. Bedside temporary cardiac pacing is generally safe and effective. Accurate assessment, correct selection of the pacing mode, and timely performance of bedside temporary cardiac pacing can further improve the survival rate and prognosis of related emergency patients.
Humans
;
Cardiac Pacing, Artificial/methods*
;
Pacemaker, Artificial
;
Arrhythmias, Cardiac/therapy*
;
Myocardial Infarction/therapy*
;
Electrodes
5.Cochlear electrode array misplacement into the superior semicircular canal: a case report and literature review.
Chen SUN ; Zhenghua HUANG ; Yingxue MA ; Ye GU ; Qi LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(4):310-312
Electrode array misplacement is a rare complication of cochlear implant. This article reports an 11-year-old boy who was mistakenly implanted the cochlear electrode array into the superior semicircular canal during the initial cochlear implant. After the diagnosis was confirmed, he underwent a second cochlear implant and the electrode array were successfully implanted into the cochlea. This article conducted a systematic review of the literature on electrode array misplacement, and the causes of electrode array misplacement were analyzed from different implantation position.
Male
;
Humans
;
Child
;
Electrodes, Implanted
;
Reoperation
;
Cochlea
;
Cochlear Implantation
;
Cochlear Implants/adverse effects*
;
Semicircular Canals/surgery*
7.Feasibility and safety of bridge therapy with active fixed electrodes connected to external permanent pacemakers for patients with infective endocarditis after lead removal and before permanent pacemaker implantation.
Jin Shan HE ; Jiang Bo DUAN ; Si Cong LI ; Zeng Li XIAO ; Long WANG ; Ding LI ; Feng ZE ; Cun Cao WU ; Cui Zhen YUAN ; Xue Bin LI
Chinese Journal of Cardiology 2022;50(12):1214-1219
Objective: To analyze the feasibility and safety of bridge therapy with active fixed electrodes connected to external permanent pacemakers (AFLEP) for patients with infective endocarditis after lead removal and before permanent pacemaker implantation. Methods: A total of 44 pacemaker-dependent patients, who underwent lead removal due to infective endocarditis in our center from January 2015 to January 2020, were included. According to AFLEP or temporary pacemaker option during the transition period, patients were divided into AFLEP group or temporary pacemaker group. Information including age, sex, comorbidities, indications and types of cardial implantable electionic device (CIED) implantation, lead age, duration of temporary pacemaker or AFLEP use, and perioperative complications were collected through Haitai Medical Record System. The incidence of pacemaker perception, abnormal pacing function, lead perforation, lead dislocation, lead vegetation, cardiac tamponade, pulmonary embolism, death and newly infection of implanted pacemaker were compared between the two groups. Pneumothorax, hematoma and the incidence of deep vein thrombosis were also analyzed. Results: Among the 44 patients, 24 were in the AFLEP group and 20 in the temporary pacemaker group. Age was younger in the AFLEP group than in the temporary pacemaker group (57.5(45.5, 66.0) years vs. 67.0(57.3, 71.8) years, P=0.023). Male, prevalence of hypertension, diabetes mellitus, chronic renal dysfunction and old myocardial infarction were similar between the two groups (all P>0.05). Lead duration was 11.0(8.0,13.0) years in the AFLEP group and 8.5(7.0,13.0) years in the temporary pacemaker group(P=0.292). Lead vegetation diameter was (8.2±2.4)mm in the AFLEP group and (9.1±3.0)mm in the temporary pacemaker group. Lead removal was successful in all patients. The follow-up time in the AFLEP group was 23.0(20.5, 25.5) months, and the temporary pacemaker group was 17.0(14.5, 18.5) months. In the temporary pacemaker group, there were 2 cases (10.0%) of lead dislocation, 2 cases (10.0%) of sensory dysfunction, 2 cases (10.0%) of pacing dysfunction, and 2 cases (10.0%) of death. In the AFLEP group, there were 2 cases of abnormal pacing function, which improved after adjusting the output voltage of the pacemaker, there was no lead dislocation, abnormal perception and death. Femoral vein access was used in 8 patients (40.0%) in the temporary pacemaker group, and 4 patients developed lower extremity deep venous thrombosis. There was no deep venous thrombosis in the AFLEP group. The transition treatment time was significantly longer in the AFLEP group than in the temporary pacemaker group (19.5(16.0, 25.8) days vs. 14.0(12.0, 16.8) days, P=0.001). During the follow-up period, there were no reinfections with newly implanted pacemakers in the AFLEP group, and reinfection occurred in 2 patients (10.0%) in the temporary pacemaker group. Conclusions: Bridge therapy with AFLEP for patients with infective endocarditis after lead removal and before permanent pacemaker implantation is feasible and safe. Compared with temporary pacemaker, AFLEP is safer in the implantation process and more stable with lower lead dislocation rate, less sensory and pacing dysfunction.
Humans
;
Male
;
Bridge Therapy
;
Feasibility Studies
;
Pacemaker, Artificial
;
Endocarditis, Bacterial/etiology*
;
Electrodes
;
Device Removal
8.Construction and performance analysis of a microbial electrochemical sensor for monitoring heavy metals in water environment.
Xiaoxiao LIU ; Fei YE ; Chuanchao WEI ; Mingjie ZHAO ; Yongtian LI
Chinese Journal of Biotechnology 2022;38(5):1903-1914
A microbial fuel cell (MFC)-based microbial electrochemical sensor was developed for real-time on-line monitoring of heavy metals in water environment. The microbial electrochemical sensor was constructed with staggered flow distribution method to optimize the parameters such as external resistance value and external circulation rate. The inhibition of concentration of simulated heavy metal wastewater on voltage under optimal parameters was analyzed. The results showed that the best performance of MFC electrochemical sensor was achieved when the external resistance value was 130 Ω and the external circulation rate was 1.0 mL/min. In this case, the microbial electrochemical sensors were responsive to 1-10 mg/L Cu2+, 0.25-1.25 mg/L Cd2+, 0.25-1.25 mg/L Cr6+ and 0.25-1.00 mg/L Hg2+ within 60 minutes. The maximum rejection rates of the output voltage were 92.95%, 73.11%, 82.76% and 75.80%, respectively, and the linear correlation coefficients were all greater than 0.95. In addition, the microbial electrochemical sensor showed a good biological reproducibility. The good performance for detecting heavy metals by the newly developed microbial electrochemical sensor may facilitate the real-time on-line monitoring of heavy metals in water environment.
Bioelectric Energy Sources
;
Electrodes
;
Metals, Heavy/analysis*
;
Reproducibility of Results
;
Waste Water
;
Water
9.Development of Non-invasive Endoscope System with Magnetic Anchored Ablation Electrode for Early Cancer of Digestive Tract.
Cheng ZHANG ; Xichen YUAN ; Peng SHANG
Chinese Journal of Medical Instrumentation 2022;46(1):1-4
This study introduces a non-invasive gastrointestinal early cancer magnetic anchor ablation electrode endoscopy system, including a magnetic anchor module and ablation electrode module. The magnetic anchoring module is composed of an external guide magnet and an internal magnet, made of permanent magnet material NdFeB; the ablation electrode module is based on the modification of the front end lens hood of the existing endoscope (CMD-90D LED electronic upper gastrointestinal endoscope). The new endoscope system not only includes all the functions of the original endoscope, but also introduces magnetic anchoring to enable the ablation electrode to be accurately positioned and controllable in the process of treating tumors, avoiding the phenomenon of gastric perforation; the introduction of steep pulse electric field ablation electrodes realizes the purpose of non-invasive treatment. Its clinical application will become a new method to treat early cancer of the digestive tract.
Electrodes
;
Endoscopes
;
Gastrointestinal Tract
;
Humans
;
Magnetic Phenomena
;
Neoplasms
10.Design and Application of Home Wireless Electrocardiograph Machine Based on Internet.
Chinese Journal of Medical Instrumentation 2022;46(3):269-272
This study introduces the design and application of home wireless electrocardiograph(ECG) machine based on Internet. The world's first three-lead dry electrode mobile electrocardiograph machine has been developed, on the basis of the successful development of dry electrodes. Moreover, it is not only chips filtering, but also wireless, as a result it is applied to ECG monitoring and diagnosis of patients. Compared with traditional electrocardiograph machine, the machine is very convenient and comes into the home, ECG Machines is connected to mobile phones by Bluetooth, wireless upload, therefore we recommend to achieve remote monitoring and early warning and reduce sudden death, to achieve Internet medical by using Internet technology, people can be self-test. It is playing an increasingly important role and it is an inevitable machine to improve the success rate of diagnosis, monitoring and first aid.
Cell Phone
;
Electrocardiography
;
Electrodes
;
Humans
;
Internet
;
Wireless Technology

Result Analysis