1.Risk assessment of genotoxicity and cytotoxicity of cone beam computed tomography exposure: A systematic review.
Marini Arisandy ; Dwi Putri Wulansari ; Barunawaty Yunus
Acta Medica Philippina 2026;60(6):92-98
OBJECTIVE
The aim of this study was to qualitatively review the effects of genotoxicity and cytotoxicity on buccal mucosal epithelial cells after cone beam computed tomography (CBCT) exposure focusing on DNA damage and cell changes.
METHODSA literature search was carried out in PubMed, Wiley, Google Scholar, and Semantic Scholar for articles published in the last five years. In vivo studies that analyzed the DNA damage and cell changes on buccal mucosal epithelial cells, before and several days after CBCT exposure were included in this review. This review was prepared according to the PRISMA checklist for systematic review and the risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool.
RESULTSA total of four studies were included in this review. The risk of bias analysis showed that all studies had generally good methodological quality. All the studies used buccal epithelial cells to analyze micronucleus (MN) as a parameter for DNA damage (genotoxicity), three of the studies also analyzed cytotoxicity using pyknotic nucleus and three studies analyzed karyolysis and karyorrhexis. All the studies consistently reported a significant increase in MN frequency, and cytotoxic effect were more evident before and 10-15 days after CBCT exposure.
CONCLUSIONThis study demonstrated a significant impact on DNA and cell damage in oral mucosal cells following CBCT examination. The effect of ionizing radiation from CBCT has a more pronounced impact on cell damage than DNA damage.
Cone-beam Computed Tomography ; Epithelial Cells ; Dna Damage ; Dna
2.Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality.
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU
Chinese Journal of Medical Instrumentation 2025;49(2):176-180
OBJECTIVE:
To investigate the influence of different scanning conditions on the image quality of medical electron accelerator cone-beam computed tomography (CBCT) and provide a reference for the selection of scanning conditions for different body parts. Methods Set different scanning conditions, the Catphan 503 phantom was scanned using CBCT parameters to analyze the influence of spatial resolution, noise, uniformity, spatial geometric accuracy, and low-contrast resolution on the image quality of CBCT.
RESULTS:
For the head, chest, and abdomen, with the increase in scanning parameter values, the noise value decreased by 47.4%, 26.1%, and 51.3% respectively, and the uniformity values decreased by 30.2%, 26.6%, and 47.9% respectively. The low-contrast resolution values decreased by 50.6%, 34.2%, and 12.0%. The influence of different scanning conditions on spatial geometric accuracy and spatial resolution is not significant.
CONCLUSION
Different scanning parameters have a certain influence on the image quality of medical electron accelerator CBCT. Lower scanning parameters can be selected based on individual patients to reduce the additional radiation dose, providing a reference for the safe application of CBCT image guidance in radiotherapy.
Cone-Beam Computed Tomography/instrumentation*
;
Phantoms, Imaging
;
Particle Accelerators
3.Accuracy Assessment of Cone-Beam CT Images for Pelvic Tumor Dose Calculation.
Bao LI ; Yongzhong CHEN ; Jun JIN ; Longjun YAN ; Xiaoyong WANG
Chinese Journal of Medical Instrumentation 2025;49(3):302-307
OBJECTIVE:
To evaluate the feasibility and accuracy of cone-beam CT (CBCT) images for radiotherapy dose calculation in pelvic tumors.
METHODS:
An improved volumetric density coverage method was used to establish CT value-relative electron density (RED) curves for CBCT images. The planning CT plans were transferred to the CBCT images, and the constructed density curves were applied to calculate doses for CBCT plans while maintaining the optimization parameters unchanged. Dose calculation deviations between the two plans were analyzed.
RESULTS:
The mean differences in dosimetric parameters for the target volume and organs at risk (OAR) between the two plans were less than 1% and 1.5%, respectively. The target conformity index (CI), homogeneity index (HI), and gamma passing rates were highly consistent, with no statistically significant differences.
CONCLUSION
CBCT images corrected by this method can be used for dose calculation in pelvic tumor radiotherapy planning.
Cone-Beam Computed Tomography/methods*
;
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Radiotherapy Dosage
;
Pelvic Neoplasms/diagnostic imaging*
4.Quantitative Analysis of the Impact of Various iCBCTs on the Image Quality of Lung Adaptive Radiotherapy.
Ruifeng ZHAO ; Bin SU ; Xiaofei JIANG
Chinese Journal of Medical Instrumentation 2025;49(4):423-428
OBJECTIVE:
To investigate the impact of different iterative cone beam CT (iCBCT) scanning beam currents from a ring-mounted linac on synthetic CT image quality for lung adaptive radiotherapy under lung scanning protocol.
METHODS:
The CIRS lung motion phantom was configured to simulate conventional respiratory motion pattern, followed by 4D-CT simulation. After transferring the radiotherapy plan to the ring-mounted Halcyon 3.0 linac, three groups of typical iCBCT scans with different beam currents [ I low (160 mA), I middle (282 mA), and I high (491 mA)] were performed and corresponding image reconstructions were completed. Synthetic CT (sCT) images were subsequently obtained based on the deformable registration algorithm.
RESULTS:
Compared to the corresponding CBCT images, the sCT images exhibited a significant reduction in artifacts. The fine structure of the planning CT (pCT) image was preserved for sCT images corresponding to different scanning beam currents, with Dice similarity coefficients exceeding 0.90 for all cases.
CONCLUSION
The image quality of sCT corresponding to different iCBCTs is comparable to that of pCT, and changes in iCBCT beam parameters have a negligible impact on sCT image quality. Taking into account both image quality and imaging dose factors associated with the beam currents, iCBCT with a lower beam current on the ring-mounted Halcyon linac offers greater clinical value in lung adaptive radiotherapy.
Cone-Beam Computed Tomography/methods*
;
Phantoms, Imaging
;
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Lung/diagnostic imaging*
;
Lung Neoplasms/diagnostic imaging*
5.PE-CycleGAN network based CBCT-sCT generation for nasopharyngeal carsinoma adaptive radiotherapy.
Yadi HE ; Xuanru ZHOU ; Jinhui JIN ; Ting SONG
Journal of Southern Medical University 2025;45(1):179-186
OBJECTIVES:
To explore the synthesis of high-quality CT (sCT) from cone-beam CT (CBCT) using PE-CycleGAN for adaptive radiotherapy (ART) for nasopharyngeal carcinoma.
METHODS:
A perception-enhanced CycleGAN model "PE-CycleGAN" was proposed, introducing dual-contrast discriminator loss, multi-perceptual generator loss, and improved U-Net structure. CBCT and CT data from 80 nasopharyngeal carcinoma patients were used as the training set, with 7 cases as the test set. By quantifying the mean absolute error (MAE), peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), as well as the dose gamma pass rate and the relative dose deviations of the target area and organs at risk (OAR) between sCT and reference CT, the image quality and dose calculation accuracy of sCT were evaluated.
RESULTS:
The MAE of sCT generated by PE-CycleGAN compared to the reference CT was (56.89±13.84) HU, approximately 30% lower than CBCT's (81.06±15.86) HU (P<0.001). PE-CycleGAN's PSNR and SSIM were 26.69±2.41dB and 0.92±0.02 respectively, significantly higher than CBCT's 21.54±2.37dB and 0.86±0.05 (P<0.001), indicating substantial improvements in image quality and structural similarity. In gamma analysis, under the 2 mm/2% criterion, PE-CycleGAN's sCT achieved a pass rate of (90.13±3.75)%, significantly higher than CBCT's (81.65±3.92)% (P<0.001) and CycleGAN's (87.69±3.50)% (P<0.05). Under the 3 mm/3% criterion, PE-CycleGAN's sCT pass rate of (90.13±3.75)% was also significantly superior to CBCT's (86.92±3.51)% (P<0.001) and CycleGAN's (94.58±2.23)% (P<0.01). The mean relative dose deviation of the target area and OAR between sCT and planned CT was within ±3% for all regions, except for the Lens Dmax (Gy), which had a deviation of 3.38% (P=0.09). The mean relative dose deviations for PTVnx HI, PTVnd HI, PTVnd CI, PTV1 HI, PRV_SC, PRV_BS, Parotid, Larynx, Oral, Mandible, and PRV_ON were all less than ±1% (P>0.05).
CONCLUSIONS
PE-CycleGAN demonstrates the ability to rapidly synthesize high-quality sCT from CBCT, offering a promising approach for CBCT-guided adaptive radiotherapy in nasopharyngeal carcinoma.
Humans
;
Cone-Beam Computed Tomography/methods*
;
Nasopharyngeal Neoplasms/diagnostic imaging*
;
Nasopharyngeal Carcinoma/radiotherapy*
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Radiotherapy Dosage
;
Signal-To-Noise Ratio
;
Radiotherapy, Intensity-Modulated
6.A sparse-view cone-beam CT reconstruction algorithm based on bidirectional flow field- guided projection completion.
Wenwei LI ; Zerui MAO ; Yongbo WANG ; Zhaoying BIAN ; Jing HUANG
Journal of Southern Medical University 2025;45(2):395-408
OBJECTIVES:
We propose a sparse-view cone-beam CT reconstruction algorithm based on bidirectional flow field guided projection completion (BBC-Recon) to solve the ill-posed inverse problem in sparse-view cone-beam CT imaging.
METHODS:
The BBC-Recon method consists of two main modules: the projection completion module and the image restoration module. Based on flow field estimation, the projection completion module, through the designed bidirectional and multi-scale correlators, fully calculates the correlation information and redundant information among projections to precisely guide the generation of bidirectional flow fields and missing frames, thus achieving high-precision completion of missing projections and obtaining pseudo complete projections. The image restoration module reconstructs the obtained pseudo complete projections and then refines the image to remove the residual artifacts and further improve the image quality.
RESULTS:
The experimental results on the public datasets of Mayo Clinic and Guilin Medical University showed that in the case of a 4-fold sparse angle, compared with the suboptimal method, the BBC-Recon method increased the PSNR index by 1.80% and the SSIM index by 0.29%, and reduced the RMSE index by 4.12%; In the case of an 8-fold sparse angle, the BBC-Recon method increased the PSNR index by 1.43% and the SSIM index by 1.49%, and reduced the RMSE index by 0.77%.
CONCLUSIONS
The BBC-Recon algorithm fully exploits the correlation information between projections to allow effective removal of streak artifacts while preserving image structure information, and demonstrates significant advantages in maintaining inter-slice consistency.
Algorithms
;
Cone-Beam Computed Tomography/methods*
;
Image Processing, Computer-Assisted/methods*
;
Humans
7.A segmented backprojection tensor degradation feature encoding model for motion artifacts correction in dental cone beam computed tomography.
Zhixiong ZENG ; Yongbo WANG ; Zongyue LIN ; Zhaoying BIAN ; Jianhua MA
Journal of Southern Medical University 2025;45(2):422-436
OBJECTIVES:
We propose a segmented backprojection tensor degradation feature encoding (SBP-MAC) model for motion artifact correction in dental cone beam computed tomography (CBCT) to improve the quality of the reconstructed images.
METHODS:
The proposed motion artifact correction model consists of a generator and a degradation encoder. The segmented limited-angle reconstructed sub-images are stacked into the tensors and used as the model input. A degradation encoder is used to extract spatially varying motion information in the tensor, and the generator's skip connection features are adaptively modulated to guide the model for correcting artifacts caused by different motion waveforms. The artifact consistency loss function was designed to simplify the learning task of the generator.
RESULTS:
The proposed model could effectively remove motion artifacts and improve the quality of the reconstructed images. For simulated data, the proposed model increased the peak signal-to-noise ratio by 8.28%, increased the structural similarity index measurement by 2.29%, and decreased the root mean square error by 23.84%. For real clinical data, the proposed model achieved the highest expert score of 4.4221 (against a 5-point scale), which was significantly higher than those of all the other comparison methods.
CONCLUSIONS
The SBP-MAC model can effectively extract spatially varying motion information in the tensors and achieve adaptive artifact correction from the tensor domain to the image domain to improve the quality of reconstructed dental CBCT images.
Cone-Beam Computed Tomography/methods*
;
Artifacts
;
Humans
;
Motion
;
Image Processing, Computer-Assisted/methods*
;
Signal-To-Noise Ratio
;
Algorithms
8.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
9.Comparison of upper airway volume and hyoid position after camouflage orthodontic or orthodontic-orthognathic treatment in patients with skeletal class Ⅲ malocclusion with normal-angle vertical pattern.
Hsu CHINGCHO ; Haojie LIU ; Chengzhao LIN ; Zhenhao LIU ; Ye ZHAI ; Shuyu GUO ; Rongyao XU
West China Journal of Stomatology 2025;43(1):53-62
OBJECTIVES:
This study aims to compare the effects of two orthodontic treatment modalities for skeletal class Ⅲ malocclusion on specific changes in airway volume, morphology, palatal angle, mandibular rotation, and bone displacement. Results provide scientific evidence for the selection of orthodontic treatment plans and reduce the risk of developing obstructive sleep apnea hypopnea syndrome (OSAHS).
METHODS:
Thirty-six patients diagnosed with skeletal class Ⅲ malocclusion at the Department of Orthodontics, the Affiliated Stomatological Hospital of Nanjing Medical University from September 2018 to December 2023 were divided into two groups: orthodontic-orthognathic treatment group (18 patients) and camouflage orthodontic treatment group (18 patients). Changes in airway volume, cross-sectional area, palatal angle, mandibular, and tongue positions were observed through pre- and post-operative cone beam computed tomography and 3D cephalometric measurements.
RESULTS:
In the camouflage orthodontic treatment group, nasopharyngeal volume and oropharyngeal volume statistically increased after treatment (P<0.05). In the orthodontic-orthognathic treatment group, changes in nasopharyngeal volume, nasopharyngeal airway, distance from posterior tongue to pharyngeal wall, palatal angle, mandibular rotation, and hyoid bone displacement were statistically significant after surgery (P<0.05). In the comparison between the two groups after treatment, changes in the distance from posterior tongue to pharyngeal wall, palatal angle, and distance from hyoid bone to sella turcica point were statistically significant (P<0.05).
CONCLUSIONS
Patients in the orthodontic-orthognathic treatment group showed significantly greater changes in oropharyngeal cross-sectional area, palate angle, and tongue position compared with patients in the camouflage orthodontic treatment group. As individuals susceptible to OSAHS often exhibit mandibular retrusion and decreased minimum airway cross-sectional area, special attention should be paid to airway morphology changes when adopting orthodontic-orthognathic treatment to avoid adverse consequences.
Humans
;
Hyoid Bone/diagnostic imaging*
;
Malocclusion, Angle Class III/therapy*
;
Male
;
Female
;
Cone-Beam Computed Tomography
;
Cephalometry
;
Orthodontics, Corrective/methods*
;
Adult
;
Mandible
;
Pharynx/diagnostic imaging*
;
Sleep Apnea, Obstructive/etiology*
;
Orthognathic Surgical Procedures
10.A retrospective study of the effects of different surgical procedures on the mandibular nerve canal involved by odontogenic keratocyst.
Zeyu WANG ; Chongli DU ; Dong WANG ; Xiao PENG ; Yue DU ; Hanying WANG ; Tingyi GAO ; Rui HAN ; Kai ZHANG
West China Journal of Stomatology 2025;43(1):106-113
OBJECTIVES:
This study aims to evaluate the changes in the mandibular canal following the treatment of large odontogenic keratocysts through decompression and curettage, providing a theoretical basis for sequential treatment.
METHODS:
Twenty patients were selected for each decompression and curettage treatment of large odontogenic keratocysts in the mandible. Postoperative follow-up with was conducted every three months, during which cone beam computed tomography (CBCT) scans were performed. Then, the data were imported into MIMICS software to observe 3D changes in the position and structure of the mandibular nerve canal, followed by a comparative analysis.
RESULTS:
The total displacement of the mandibular canal was (1.89±0.21) mm on the decompression side and (0.80±0.19) mm on the curettage side. Vertically, the displacement range of the mandibular canal on the decompression side (M=1.03, SD=0.17) was larger than on the curettage side (M=0.52, SD=0.010) within nine months post-operation. In the buccal-lingual direction, the ratio of the thickness of the buccal plate to the lingual plate gradually increased with time. The amount of bone reconstruction at the part of the mandibular nerve canal closest to the cyst was (1.75±0.15) mm on the decompression side and (1.45±0.09) mm on the curettage side after nine months.
CONCLUSIONS
The mandibular nerve canal showed varying degrees of recovery and "relocation" after two surgical procedures. Osteogenesis around the mandibular nerve canal was more remarkable after decompression than after curettage. Therefore, for large odontogenic keratocyst, decompression is recommended as the initial treatment, followed by secondary curettage nine months later.
Humans
;
Odontogenic Cysts/diagnostic imaging*
;
Retrospective Studies
;
Cone-Beam Computed Tomography
;
Decompression, Surgical/methods*
;
Mandibular Nerve/surgery*
;
Mandible/innervation*
;
Curettage
;
Male
;
Female
;
Adult
;
Middle Aged


Result Analysis
Print
Save