1.Profiling the chemical differences of diterpenoid alkaloids in different processed products of Aconiti Lateralis Radix Praeparata by UHPLC-LTQ-Orbitrap mass spectrometry combined with untargeted metabolomics and mass spectrometry imaging.
Yang YU ; Changliang YAO ; Jianqing ZHANG ; Yong HUANG ; Shuai YAO ; Hua QU ; Tong ZHANG ; Dean GUO
Chinese Journal of Natural Medicines (English Ed.) 2025;23(8):1009-1015
Aconiti Lateralis Radix Praeparata (Fuzi) represents a significant traditional Chinese medicine (TCM) that exhibits both notable pharmacological effects and toxicity. Various processing methods are implemented to reduce the toxicity of raw Fuzi by modifying its toxic and effective components, primarily diterpenoid alkaloids. To comprehensively analyze the chemical variations between different Fuzi products, ultra-high performance liquid chromatography-linear ion trap quadrupole Orbitrap mass spectrometry (UHPLC-LTQ-Orbitrap MS) was employed to systematically characterize Shengfuzi, Heishunpian and Baifupian. A total of 249 diterpenoid alkaloids present in Shengfuzi were identified, while only 111 and 61 in Heishunpian and Baifupian were detected respectively, indicating substantial differences among these products. An untargeted metabolomics approach combined with multivariate statistical analysis revealed 42 potential chemical markers. Through subsequent validation using 52 batches of commercial Heishunpian and Baifupian samples, 8 robust markers distinguishing these products were identified, including AC1-propanoic acid-3OH, HE-glucoside, HE-hydroxyvaleric acid-2OH, dihydrosphingosine, N-dodecoxycarbonylvaline and three unknown compounds. Additionally, the MS imaging (MSI) technique was utilized to visualize the spatial distribution of chemical constituents in raw Fuzi, revealing how different processing procedures affect the chemical variations between Heishunpian and Baifupian. The distribution patterns of different diterpenoid alkaloid subtypes partially explained the chemical differences among products. This research provides valuable insights into the material basis for future investigations of different Fuzi products.
Diterpenes/chemistry*
;
Alkaloids/chemistry*
;
Chromatography, High Pressure Liquid/methods*
;
Aconitum/chemistry*
;
Drugs, Chinese Herbal/chemistry*
;
Metabolomics
;
Mass Spectrometry/methods*
;
Plant Roots/chemistry*
;
Molecular Structure
2.Establishment and optimization of a high-performance size-exclusion chromatography method for quantifying the classical swine fever virus E2 protein.
Xiaojuan ZHANG ; Bo YANG ; Gaoyuan XU ; Mingxing REN ; Ji TANG ; Hongshuo LIU ; Zhankui LIU ; Yafei LI ; Xiangru WANG
Chinese Journal of Biotechnology 2025;41(7):2774-2788
This study aims to establish a high-performance size-exclusion chromatography (HPSEC) method for determining the content of the classical swine fever virus (CSFV) E2 protein and screen the optimal stabilizer to enhance the stability of this protein. The optimal detection conditions were determined by optimizing the composition of the mobile phase, and characteristic chromatographic peaks were identified by SDS-PAGE and Western blotting. The specificity, repeatability, precision, linearity, limit of detection (LOD), and limit of quantitation (LOQ) of the method were assessed. The method established was used to determine the content of CSFV E2 protein antigen and vaccine. Differential scanning fluorimetry (DSF) was employed to screen the buffer system, pH, and salt ion concentrations, and sugar, amino acid, and alcohol stabilizers were further screened. The results showed that using a 200 mmol/L phosphate buffer provided the best column efficiency. An antigen-specific chromatographic peak appeared at the retention time of 18 min, which was identified as the CSFV E2 protein by SDS-PAGE and Western blotting. The method exhibited high specificity for detecting the CSFV E2 protein, with no absorbance peak observed in the blank control. The relative standard deviation (RSD) of the peak area for six repeated injections of the CSFV E2 protein was 0.74%, indicating good repeatability of the method. The RSD for repeated detection of two different concentrations of CSFV E2 protein samples by different operators at different time points was less than 2%, suggesting good intermediate precision of the method. The peak area of the CSFV E2 protein was linearly related to its concentration, with the regression equation showing R2 of 1.000. The LOD and LOQ of the method were 14.88 μg/mL and 29.75 μg/mL, respectively. Application of the developed method in the detection of three batches of CSFV E2 protein antigen and three batches of vaccine demonstrated results consistent with those from the bicinchoninic acid (BCA) assay, which meant that the method could accurately determine the content of CSFV E2 protein antigen and vaccine. The DSF method identified 50 mmol/L Tris-HCl at pH 8.0 as the optimal buffer, and the addition of sugar and alcohol stabilizers further improved the stability of the CSFV E2 protein. The HPSEC method established in this study is simple, fast, and exhibits good accuracy and repeatability, enabling precise measurement of the CSFV E2 protein content. It is expected to play a crucial role in the quality control of the CSFV E2 vaccine. Furthermore, the strategy for improving the CSFV E2 protein stability, identified through DSF screening, has significant implications for enhancing the stability of the CSFV E2 vaccine.
Classical Swine Fever Virus/chemistry*
;
Chromatography, Gel/methods*
;
Animals
;
Swine
;
Viral Envelope Proteins/immunology*
3.Preparation of monoclonal antibodies with high specificity for glycated hemoglobin and establishment of a rapid detection method.
Chaofan YIN ; Yingfu ZHANG ; Kebei WANG ; Jichuang WANG ; Yongwei LI ; Xiaojun WANG ; Xudong WANG ; Panpan SHI ; Yunlong WANG
Chinese Journal of Biotechnology 2025;41(8):3165-3177
Hemoglobin A1c (HbA1c) has a unique structure that makes monoclonal antibody (mAb) preparation challenging. This study aims to develop a method for preparing HbA1c mAbs and establish a fluorescent immunochromatographic assay (FICA) for rapid detection of HbA1c. Three glycosylated peptides were synthesized and used to prepare complete antigens, which were identified by dot enzyme-linked immunosorbent assay (Dot-ELISA) and ultraviolet absorption spectroscopy. The complete antigens and natural HbA1c were used for cross-immunization of mice, and the optimal complete antigen was selected. The mouse with the highest serum titer was chosen for mAb preparation. The purity and specificity of the mAbs were verified, and a FICA method was developed. The optimal complete antigen, with a titer of 1:512 000, was successfully prepared and selected. Fusion with splenocytes resulted in four specific HbA1c antibodies (purity > 90%). The best antibody exhibited a binding constant (Ka) of 1.67×1010 L/mol with the antigen. Based on this antibody, a FICA method was successfully established, capable of producing results within 15 min. The method demonstrated a good linear range (3%-13% HbA1c, y=0.071 3x+0.005 6, R2=0.993 7), recovery rates of 98%-102%, precision < 10.00%, and no nonspecific reactions. Clinical testing of 210 samples showed positive agreement of 96.36%, negative agreement of 97.00%, and overall agreement of 96.68%. The receiver operating characteristic (ROC) curve analysis yielded an area under curve (AUC) of 0.980 9 [95% confidence interval (CI): 0.961 0-1.000 0], with high consistency verified in multicenter studies. We successfully developed a key technique for preparing HbA1c monoclonal antibodies and established a FICA method for rapid detection of HbA1c. It will provide an efficient and convenient detection method for the early diagnosis and long-term management of diabetes and its complications.
Antibodies, Monoclonal/biosynthesis*
;
Animals
;
Mice
;
Glycated Hemoglobin/immunology*
;
Mice, Inbred BALB C
;
Humans
;
Antibody Specificity
;
Chromatography, Affinity/methods*
;
Enzyme-Linked Immunosorbent Assay/methods*
;
Female
4.An electrostatically coupled polypeptide affinity multimodal chromatography medium for the purification of antibodies and their separation efficiency.
Yuxuan CHENG ; Liuyang WANG ; Kaixuan JIANG ; Songping ZHANG ; Hongbo YAN ; Jian LUO
Chinese Journal of Biotechnology 2025;41(8):3262-3274
As the need for antibody production rises, there is an urgent need to lower the costs and enhance the efficiency of the separation process. Currently, the chromatographic media used for antibody separation and purification often focus on individual properties of antibodies, such as affinity, hydrophobicity, and charge, leading to issues like low purification efficiency or inadequate adsorption capacity. To address this, an electrostatically coupled polypeptide affinity medium (FD7-3, 5-diaminobenzoic acid n-sepharose, FD7-DA-Sepharose) was developed for rapid purification of antibodies from cell culture supernatant. This medium utilized 3, 5-diaminobenzoic acid as a spacer to attach the heptapeptide-affinity ligand (FYEILHD, FD7) to agarose microspheres. Antibodies could be adsorbed through charge interactions with the carboxyl functional group of the FD7-DA-Sepharose spacer, while FD7 enhanced electrostatic coupling and affinity adsorption through synergistic effects, significantly increasing the adsorption capacity while maintaining the affinity and specificity. The influences of pH and ionic strength on adsorption capacity were investigated with human immunoglobulin as a model protein. The static adsorption capacity (Qm) of FD7-DA-Sepharose in the solution of pH 6.0 reached 67.73 mg/mL, representing a 52.68% increase compared with that (44.36 mg/mL) of the commercial Protein A affinity medium. Furthermore, the elution conditions for FD7-DA- Sepharose were mild (20 mmol/L PB, 0.5 mol/L NaCl, pH 6.0), in contrast to the harsh acidic elution (pH 2.7-3.6) typically associated with Protein A, which can damage antibody integrity. The FD7-DA-Sepharose medium was then employed to purify antibodies from cell culture supernatant, achieving the yield of 94.8% and the purity of 98.4%. The secondary structure of the purified antibody was determined by circular dichroism spectroscopy. The results demonstrated that FD7-DA-Sepharose enabled efficient purification of antibodies from cell culture supernatant, which provided a cost-effective solution (approximately one-third the price of commercial Protein A affinity medium) with gentle elution conditions that preserve the natural conformation of antibodies. This approach paves a novel, economical, and efficient way for the separation and purification of antibodies from cell culture supernatant.
Chromatography, Affinity/methods*
;
Static Electricity
;
Humans
;
Sepharose/analogs & derivatives*
;
Peptides/chemistry*
;
Adsorption
;
Antibodies/isolation & purification*
5.Determination of Acetate Content in Hemodialysis Solutions and Dialysis Concentrates by HPLC.
Huadong WANG ; Yue WANG ; Dong LIU ; Xianghui LIU
Chinese Journal of Medical Instrumentation 2025;49(3):350-354
This study establishes a high-performance liquid chromatography (HPLC) method for the determination of acetate content in hemodialysis solutions and dialysis concentrates. In this study, Synergi Polar-RP column is utilized. Phosphate buffered saline (50 mmol/L, pH=2.5) is used as a mobile phase. The flow rate is 1.0 mL/min. The wavelength of detection is 212 nm. Results show that the linear relationship of acetate is good in the range of 0.1~20 mmol/L, r =0.999 9 and the spike recoveries are from 98.9%~99.5%, RSD<0.5% ( n=3). This method can easily and accurately determine the acetate content in hemodialysis solutions and dialysis concentrates, and can be applied to quality control in the production and use of such products.
Chromatography, High Pressure Liquid/methods*
;
Acetates/analysis*
;
Hemodialysis Solutions/analysis*
;
Dialysis Solutions/analysis*
;
Renal Dialysis
6.Determination of Volatile Organic Compounds in Medical Molecular Sieve Oxygen Concentrators by Thermal Desorption-Gas Chromatography-Mass Spectrometry.
Danmei ZHAO ; Bin XUE ; Congkai WEI ; Haihua KANG ; Yuanli HUANG ; Linnan KE
Chinese Journal of Medical Instrumentation 2025;49(5):585-590
A method for determining volatile organic compounds (VOCs) emitted from medical molecular sieve oxygen concentrators was developed using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The oxygen concentrator gas was sampled at a flow rate of 0.5 L/min through a branched sampling system onto Tenax GR/carbopack B adsorption tubes. The adsorbed compounds were desorbed and introduced using a programmed temperature vaporization inlet system, followed by chromatographic separation on an SH-I-624Sil MS column. Four VOCs (BHT-Q, PTBP, BHT-quinol, and EHB) were detected in the medical oxygen concentrator using this method. Calibration curves for these compounds exhibited excellent linearity ( R 2>0.99) within the range of 3~100 ng. With a sampling volume of 20 L, the detection limit of the four VOCs ranged from 0.003 9 to 0.022 2 μg/m 3. Spike recovery rates for the four VOCs were between 95% and 115%, with relative standard deviations (RSDs) below 5% ( n=6). The method is simple, rapid, highly sensitive, and accurate, making it suitable for VOCs detection in medical molecular sieve oxygen concentrators.
Volatile Organic Compounds/analysis*
;
Gas Chromatography-Mass Spectrometry/methods*
;
Oxygen
7.Establishment and application of a UPLC-MS/MS method for the determination of tiletamine and its metabolite in biological samples.
Zihao CAI ; Wenguang YAN ; Jiahao LI ; Yanjun DING ; Jiang LING
Journal of Central South University(Medical Sciences) 2025;50(6):1002-1012
OBJECTIVES:
Tiletamine, a veterinary anesthetic, has emerged as a novel psychoactive substance and has been abused in many parts of the world, causing great harm to public health. However, the sensitivity of existing detection methods cannot meet the needs of forensic practice. This study aims to establish an ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of tiletamine and its metabolite desethyltiletamine in human biological samples, and to verify its applicability in forensic practice.
METHODS:
SKF525A was used as the internal standard. Biological samples were extracted with acetonitrile containing 1 ng/mL SKF525A, vortexed for 10 min, ultrasonicated for 20 min, centrifuged at 10 000 r/min for 10 min, and 500 μL of the supernatant was filtered through a 0.22 μm membrane. Analyses were performed using an ACQUITY UPLC H-Class PLUS system and an XEVO TQ-S Micro triple quadrupole mass spectrometer. An ACQUITY UPLC® BEH C18 (1.7 µm, 2.1 mm×100 mm) column at a flow rate of 0.3 mL/min was used, and four mobile phase systems were tested to optimize separation. Detection used positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode, with quantifier ion transitions of mass to charge 224.043→179.016 for tiletamine and mass to charge 196.08→151.06 for desethyltiletamine. Calibration curves were established over 0.1-200 ng/mL in spiked blood samples. The linear range, limit of detection (LOD), and limit of quantification (LOQ) were determined. Low (5 ng/mL), medium (20 ng/mL), and high (100 ng/mL) concentrations of tiletamine were spiked into blood, liver, and kidney to evaluate precision, accuracy, matrix effect, recovery, and stability. Finally, actual forensic case samples were tested to validate applicability.
RESULTS:
The established UPLC-MS/MS method achieved simultaneous detection of tiletamine and desethyltiletamine in human biological samples, with retention times of 3.42 min and 2.82 min, respectively. Using mobile phase A (20 mmol/L ammonium acetate and 0.1% formic acid in water) and mobile phase B (acetonitrile) produced the best separation. In blood, tiletamine showed good linearity from 0.1-200 ng/mL (r=0.992, R2=0.983), LOD 0.03 ng/mL, LOQ 0.1 ng/mL, recovery 92%-107%, and matrix effect 71%-99%. In liver and kidney, recoveries were 91%-98% and 93%-104%, and matrix effects were 69%-96% and 72%-100%, respectively. Intra- and inter-day precision [expressed as relative standard deviation (RSD)] and accuracy [expressed as relative error (RE)] were within 15%, and samples were stable at -20 ℃. Tiletamine was detected in actual case samples at 0.37 μg/mL (blood), 0.15 μg/g (liver), 0.11 μg/g (kidney) in case 1, and 8.75 ng/mL (blood) in case 2; desethyltiletamine was also detected in blood.
CONCLUSIONS
The UPLC-MS/MS method is efficient, accurate, and sensitive, and is suitable for detecting tiletamine and desethyltiletamine in human biological samples.
Tandem Mass Spectrometry/methods*
;
Humans
;
Chromatography, High Pressure Liquid/methods*
;
Substance Abuse Detection/methods*
;
Liquid Chromatography-Mass Spectrometry
8.Dynamic changes in physiochemical, structural, and flavor characteristics of ginger-juice milk curd.
Haifeng PAN ; Wenna BAO ; Yi CHEN ; Hongxiu LIAO
Journal of Zhejiang University. Science. B 2025;26(4):393-404
Dynamic changes in the physiochemical, structural, and flavor characteristics of ginger-juice milk curd were explored by texture analysis, scanning electron microscopy, rheometry, electronic tongue, and gas chromatography-mass spectrometry (GC-MS). Protein electrophoresis showed that ginger juice could hydrolyze αs-, β-, and κ-casein. Curd formation was initiated at 90 s, marked by significant changes in intensity detected via intrinsic fluorescence. The contents of soluble protein and calcium decreased rapidly during coagulation, while the caseinolytic activity, storage moduli, loss moduli, hardness, adhesiveness, and water-holding capacity increased, resulting in a denser gel structure with smaller pores and fewer cavitations as observed by scanning electron microscopy. Electronic tongue analysis indicated that milk could neutralize the astringency and saltiness of ginger juice, rendering the taste of ginger-juice milk curd more akin to that of milk. Approximately 70 volatile components were detected in ginger-juice milk curd. α-Zingiberene, α-curcumene, β-sesquiphellandrene, and β-bisabolene were the predominant volatile flavor compounds, exhibiting an initial decrease in content followed by stability after 90 s. Decanoic acid, γ-elemene, and caryophyllene were identified as unique volatile compounds after mixing of milk and ginger juice. Understanding the dynamic changes in these characteristics during coagulation holds significant importance for the production of ginger-juice milk curd.
Zingiber officinale/chemistry*
;
Milk/chemistry*
;
Animals
;
Taste
;
Gas Chromatography-Mass Spectrometry
;
Caseins/chemistry*
;
Microscopy, Electron, Scanning
;
Rheology
;
Flavoring Agents
9.Lipid analysis in children with bronchial asthma based on liquid chromatography-mass spectrometry: a prospective study.
Te FENG ; Li-Na XIE ; Yu-Hui ZHANG ; Yan-Jun GUO
Chinese Journal of Contemporary Pediatrics 2025;27(6):716-722
OBJECTIVES:
To explore the lipidomic characteristics of children with bronchial asthma (hereafter referred to as asthma) and identify potential biomarkers for asthma.
METHODS:
A total of 26 asthmatic children were prospectively enrolled as the asthma group, and 20 healthy children served as the healthy control group. The asthma group was further divided into atopic (n=13) and non-atopic (n=13) subgroups based on IgE levels. Serum lipid metabolites were analyzed using liquid chromatography-mass spectrometry, followed by statistical analysis and data visualization.
RESULTS:
A total of 1 435 lipids were detected in the 46 children, primarily glycerophospholipids (625/1 435, 43.55%). Significant differences were observed in serum lipid profiles between the asthma and control groups. Twelve significantly differential lipids were identified, with receiver operating characteristic curve analysis showing that phosphatidylserine (PS)(18:0/20:4) and ceramide (Cer)(c16:0) exhibited the highest diagnostic value for asthma. The relative abundances of PS(18:0/20:4) and PS(18:0/22:6) were higher in the atopic subgroup than in the non-atopic subgroup (P<0.05) and positively correlated with total IgE levels in asthmatic children (r=0.675 and 0.740, respectively; P<0.05).
CONCLUSIONS
Asthmatic children exhibit significant lipid metabolic disturbances, primarily characterized by abnormal glycerophospholipid metabolism. Among these, PS(18:0/20:4) and Cer(c16:0) demonstrate specific alterations and may serve as potential diagnostic biomarkers for asthma. Furthermore, the positive correlation between PS(18:0/20:4) and PS(18:0/22:6) levels and serum total IgE suggests their possible involvement in immune regulation in asthma.
Humans
;
Asthma/metabolism*
;
Male
;
Child
;
Female
;
Prospective Studies
;
Mass Spectrometry/methods*
;
Lipids/blood*
;
Chromatography, Liquid/methods*
;
Child, Preschool
;
Immunoglobulin E/blood*
;
Biomarkers/blood*
;
Adolescent
;
Liquid Chromatography-Mass Spectrometry
10.Determination of skin-insect repellent icaridin and DEET in human urine using solid-phase extraction and liquid chromatography with tandem mass spectrometry and its application to a sample of Japanese adults.
Nanami NISHIHARA ; Tomohiko ISOBE ; Mai TAKAGI ; Toshiki TAJIMA ; Yugo KITAHARA ; Mai HAYASHI ; Isao SAITO ; Satoru WATANABE ; Miyuki IWAI-SHIMADA ; Jun UEYAMA
Environmental Health and Preventive Medicine 2025;30():18-18
BACKGROUND:
Icaridin and DEET are common insect repellents widely used on human skin and clothing (skin-insect repellents [skin-IR]) to repel common pests, such as mosquitoes and biting flies. Novel analytical methods for urinary skin-IR exposure biomarkers that can be effectively applied in epidemiological studies and provide strong evidence related to risk assessment associated with daily exposure are required. In this study, we aimed to develop a method for analyzing the concentrations of icaridin, DEET, and two DEET metabolites N,N-diethyl-3-(hydroxymethyl) benzamide and 3-(diethylcarbamoyl) benzoic acid in human urine.
METHODS:
In this analysis, after formic acid-induced acidification of the urine sample, exposure biomarkers were extracted using solid-phase extraction composed of a modified polystyrenedivinylbenzene polymer for reversed phase (hydrophobic) retention. Subsequently, high-performance liquid chromatography-tandem mass spectrometry was performed within 10 min for a separation analysis. The present method was applied to five Japanese adults (aged 20-43 years) who used icaridin or DEET-containing products within a week.
RESULTS:
Limits of detection were 0.06-0.11 µg/L. Extraction recoveries were 74%-88%. The intraday and interday variations were 1.5-17.5 and 0.9-15.8% relative standard deviation, respectively. All exposure biomarkers were successfully detected in all five adults. Urinary concentrations of exposure biomarkers reached their maximum values within 15 h after starting to use skin-IR.
CONCLUSIONS
This method was successful in measuring urinary exposure biomarkers of skin-IR, including icaridin and DEET. Moreover, this study presents the first application of biomonitoring of urinary icaridin concentrations after using a commercial product.
Humans
;
Solid Phase Extraction/methods*
;
Tandem Mass Spectrometry/methods*
;
Adult
;
Insect Repellents/urine*
;
DEET/urine*
;
Young Adult
;
Male
;
Japan
;
Female
;
Chromatography, Liquid
;
Biomarkers/urine*
;
Chromatography, High Pressure Liquid
;
East Asian People

Result Analysis
Print