1.Analysis of ABO System Hemolytic Disease of the Newborn in 283 Cases at Yunnan Province.
Jin-Yu ZHOU ; Ru SHEN ; Han-Xin WU ; Ju-Ding GUO ; Hong-Mei LIU ; Li-Li SHU ; Yu ZHU ; Jing-Yue SUN ; Jun CHANG
Journal of Experimental Hematology 2025;33(3):881-885
OBJECTIVE:
To analyze the laboratory detection results of hemolytic disease of the fetus and newborn(HDFN).
METHODS:
Related test results of 283 newborns and their mothers' blood samples from Kunming Maternal and Child Health Hospital from August 2023 to May 2024 were collected, including mother and child ABO blood group, RhD blood group, as well as 3 tests of HDFN, total bilirubin (TBil) and indirect bilirubin (IBil).
RESULTS:
283 were ABO incompatibility, among which 187 were HDFN positive, with a positive rate of 66.08%; the positive rate of HDFN in neonates with antigen-A incompatibility was 74.12%(126/170), the positive rate of HDFN in neonates with antigen-B incompatibility was 53.57%(60/112), which was the highest in neonates with O/A incompatibility [75.45%(126/167)], followed by O/B incompatibility[54.55%(60/110)]. Group by age, the positive rates of HDFN in the ≤1 d group, 2 d group, 3 d group, 4 d group, 5 d group and ≥6 d group were 76.03%(111/146), 67.86%(38/56), 57.14%(24/42), 38.46%(5/13), 46.15%(6/13) and 23.08%(3/13), respectively. With the increase of age, the positive rates of HDFN gradually decreased, there was a statistically significant difference between the ≤3 day age group and >3 day age group ( P <0.05). There was no statistically significant difference in TBil and IBil levels between the "direct antibody+indirect antibody+release+" group and the HDFN negative group in newborns. HDFN infants exhibited a rapid increase in bilirubin levels within the first day after birth, with significantly higher TBil and IBil values compared to Non ABO-HDFN infants in the ≤1 day group ( P <0.01). However, the difference of bilirubin levels between the two groups gradually narrowed from 2-6 days after birth, and the difference was not statistically significant (P >0.05). The peak value of TBil and IBil occurred on the 4th day after birth in HDFN infants.
CONCLUSION
ABO-HDFN is most commonly seen in newborns whose mothers are type-O, and the positive rate was the highest in newborns with O/A incompatibility. The detection rate of HDFN is affected by the age of the newborns, and the two were correlated inversely. ABO-HDFN group developed more rapidly with a higher peak. Therefore, HDFN tests should be carried out as soon as possible for mothers and newborns with incompatible blood types, and appropriate treatment should be provided to prevent complications.
Humans
;
Infant, Newborn
;
ABO Blood-Group System
;
Erythroblastosis, Fetal/epidemiology*
;
Female
;
China/epidemiology*
;
Blood Group Incompatibility
;
Male
;
Bilirubin/blood*
2.Correlation Analysis of Hemolytic Transfusion Reaction Induced by Low Titer Antibody.
Yuan-Yuan LUO ; Chun-Ya MA ; Li-Hui FU ; Xin YANG ; Yang YU ; De-Qing WANG
Journal of Experimental Hematology 2023;31(2):503-508
OBJECTIVE:
To establish the diagnostic process of low titer blood group antibody in the occurrence of adverse reactions of hemolytic transfusion.
METHODS:
Acid elusion test, enzyme method and PEG method were used for antibody identification. Combined with the patient's clinical symptoms and relevant inspection indexes, the irregular antibodies leading to hemolysis were detected.
RESULTS:
The patient's irregular antibody screening was positive, and it was determined that there was anti-Lea antibody in the serum. After the transfusion reaction, the low titer anti-E antibody was detected by enhanced test. The patient's Rh typing was Ccee, while the transfused red blood cells were ccEE. The new and old samples of the patient were matched with the transfused red blood cells by PEG method, and the major were incompatible. The evidence of hemolytic transfusion reaction was found.
CONCLUSION
Antibodies with low titer in serum are not easy to be detected, which often lead to severe hemolytic transfusion reaction.
Humans
;
Blood Transfusion
;
Transfusion Reaction/prevention & control*
;
Hemolysis
;
Blood Group Antigens
;
Erythrocyte Transfusion
;
Antibodies
;
Isoantibodies
;
Blood Group Incompatibility
4.The Correlation Analysis between the Titer of IgG Anti-A/B Erythrocyte Antibody In Vivo of the Neonate and the Severity of Hemolytic Disease of Newborn.
Jian SONG ; Ting YANG ; Xiao-Fang ZHOU ; Yin-Zhong YANG ; Duan-Liang PENG ; Jian-Bo ZHANG
Journal of Experimental Hematology 2022;30(2):547-551
OBJECTIVE:
To investigate the titer of IgG anti-A/B erythrocyte antibody in vivo of the neonate with hemolytic disease of newborn(HDN), and explore its clinical valua in evaluating the severity of HDN.
METHODS:
300 neonates with HDN, 50 neonates with neonatal hyperbilirubinemiain and 50 healthy neonates were selected as research object and Microtubes Gel Test was used to detect the titer of IgG anti-A/B erythrocyte antibody in vivo. Their clinical data and their mothers' prenatal examination data were retrospectively analyzed. Three hemolysis tests (direct antiglobulin test, free antibody test and release test), irregular antibody screening, and the titer of IgG anti-A/B blood group antibody was determined by serological method. Red blood cells(RBC), hemoglobin(Hb), reticulocytes(Ret) and nucleated red cells were detected by hematology analyzer. Indirect bilirubin and albumin(Alb) were detected by biochemical analyzer. The relationship between the titer of IgG anti-A/B erythrocyte antibody in vivo and the severity of HDN was analyzed.
RESULTS:
There were six serological diagnosis modes in the HDN group,the difference between modes was statistically significant (P<0.05). The antibody titer relationship between HDN neonates and pregnant women was positive correlation(r=0.8302). The highest antibody titer of release test and free antibody test were 1∶32 and 1∶2, and the difference was statistically significant(P<0.05). RBC, Hb and Alb in HDN patients were lower than those in neonatal hyperbilirubinemia patients and healthy neonates (P<0.05), and were negatively relevant with antibody titer in vivo (r=-0.8016). Bilirubin content in HDN patients were higher than those in neonatal hyperbiliru binemia patients and healthy neonates group(P<0.05), and was positively relevant with antibody titer in vivo (r=0.8731). The hospital day in HDN patients was significantly relevant with the antibody titer in vivo (r=0.8547), but not with the age, sex, weight and ABO blood types (P>0.05).
CONCLUSION
The detection of antibody titer in HDN patients can be used to evaluate the antibody concentration in vivo, predict the ability of antibody to induce erythrocyte hemolysis, and help to judge the serenrity and prognosis of HDN.
ABO Blood-Group System
;
Bilirubin
;
Blood Group Incompatibility
;
Erythroblastosis, Fetal
;
Erythrocytes
;
Female
;
Hematologic Diseases
;
Hemolysis
;
Humans
;
Immunoglobulin G
;
Infant, Newborn
;
Pregnancy
;
Retrospective Studies
5.Investigation and Analysis of Non-ABO Hemolytic Disease of the Newborn.
Yan-Ling ZHENG ; Qiang HONG ; Qian-Ming WANG
Journal of Experimental Hematology 2021;29(4):1330-1333
OBJECTIVE:
To study the serological detection characteristics and antibody specific distribution of hemolytic disease of the newborn (HDN) caused by irregular antibodies through retrospective case analysis.
METHODS:
A total of 3 047 suspected cases of HDN were submitted by the Neonatal Department of our hospital from January 2014 to December 2019. Non ABO-HDN cases confirmed in our laboratory were taken as the research objects, while some cases of ABO-HDN were randomly selected as control. Disease-causing antibody specificity, serological detection characteristics, total bilirubin change trend and gender ratio of non ABO-HDN patients were explored.
RESULTS:
Sixty-seven cases of non ABO-HDN were confirmed from the suspected cases of HDN, Among which 45 males and 22 females were detected with the positive rate 1.48% and 0.72%, respectively. The mothers of 65 cases had two or more pregnancies. The detected irregular antibodies were mainly involved with Rh system, MNS system, Kidd system and Lewis system, among which Rh system accounted for 88.07% of the total antibody detection rate. Compared with that of ABO-HDN patients, the total bilirubin of non ABO-HDN patients developed more rapidly with a higher peak and a longer duration (P<0.001). In terms of serological detection, the positive rate of non ABO-HDN direct antibody test was 97.01%, which was higher than 47.00% of ABO-HDN (P<0.001), and the agglutination strength was often ≥ 2+, but there were still weak positive or negative cases of direct antibody test.
CONCLUSION
Non ABO-HDN caused by irregular antibodies mostly occurs in fetuses whose mothers experience multiple pregnancies, and the number of males is more than females. The irregular antibodies detected are mainly attributed to Rh system. The peak value of bilirubin in non ABO-HDN patients is higher and lasts longer than that in ABO-HDN patients. Direct antiglobulin test may be used to roughly distinguish ABO-HDN from non ABO-HDN.
ABO Blood-Group System
;
Blood Group Incompatibility
;
Coombs Test
;
Erythroblastosis, Fetal
;
Female
;
Humans
;
Infant, Newborn
;
Male
;
Pregnancy
;
Retrospective Studies
6.Transfusion Strategy for Rare Anti-LW Antibody Autoimmune Hemolytic Anemia Patients with Neonatal Hemolytic Disease.
Dong-Dong TIAN ; Ding ZHAO ; Zhi-Hao LI ; Wei LI ; Jia-Li YANG ; Xiao-Pan ZHANG ; Liu-Chuang ZHENG
Journal of Experimental Hematology 2021;29(6):1935-1939
OBJECTIVE:
To analyze the causes of positive irregular antibody screening test and incompatibility of cross matching in one patient with autoimmune hemolytic anemia complicated with neonatal hemolytic disease, and to accurately identify the type of antibodies in patients, and to select a reasonable strategy for blood transfusion.
METHODS:
One children was enrolled, blood group positive and reverse typing, Rh typing, direct anti-human globulin test, free test, dispersal test and cross matching test were carried out by test tube method and microcolumn gel card; irregular antibodies were identified by the reaction of DTT treatment and untreated panel cells with patients' plasma.
RESULTS:
The blood group of the patient was RhD positive B and irregular antibody screening positive, while the blood group of the mother was RhD positive O and irregular anti-screening negative, the result showed that the anti-LW detected in the plasma of the patient was autoantibody and ABO neonatal hemolytic disease (ABO-HDN) was present. Both O type RhD positive washing RBCs and B type RhD negative RBCs were transfused effectively.
CONCLUSION
Irregular antibodies in patients are anti-LW antibodies, and transfusion of homotype RhD negative suspended erythrocytes after the exclusion of ABO-HDN shows a better effect.
Anemia, Hemolytic, Autoimmune
;
Autoantibodies
;
Blood Group Incompatibility
;
Blood Transfusion
;
Erythroblastosis, Fetal
;
Humans
7.Effects of Neutralization by Soluble ABH Antigens Produced by Transplanted Kidneys From ABO-Incompatible Secretor Donors.
Jieun KIM ; Sinyoung KIM ; In Sik HWANG ; Jong Rak CHOI ; Jae Geun LEE ; Yu Seun KIM ; Myoung Soo KIM ; Hyun Ok KIM
Annals of Laboratory Medicine 2017;37(3):254-260
BACKGROUND: Grafts survive despite blood group antigens on the transplant being continuously exposed to antibodies in the blood of recipients in ABO-incompatible kidney transplantation (ABOi KT), owing to the mechanism of accommodation. We analyzed the immunodynamics of soluble ABH antigens in allografts from secretor donors and the influence of such immunodynamics on accommodation and subsequent graft survival in ABOi KT. METHODS: The genotype of a known human β-galactoside α-1,2-fucosyltransferase gene (FUT2), which determines soluble ABH antigen secretor status, was established in 32 donors for ABOi KT at the Severance Hospital, from June 2010 to July 2015. Clinical outcomes of recipients, such as anti-A/B antibody titer change, renal function, and graft survival, were evaluated. RESULTS: Twenty-five donors were secretors (78.1%), and seven were nonsecretors (21.9%). The frequency of anti-A/B IgG or IgM antibody titer elevation or reduction post-transplantation was not significantly related to donor secretor status. However, IgM titer was rapidly reduced in recipients transplanted from nonsecretor donors (P=0.01), which could be explained by the lack of absorption effect of soluble antigens, enhancing the binding of antibodies to antigens in the allografts. Interestingly, soluble ABH antigens did not affect rejection-free graft survival, which may be due to the nature of β-galactoside α-1,2-fucosyltransferase. CONCLUSIONS: Soluble ABH antigens produced by transplanted kidneys from secretor donors played a role in inducing accommodation within three months of KT through neutralization; however, major graft outcomes were not affected.
Absorption
;
Allografts
;
Antibodies
;
Blood Group Antigens
;
Blood Group Incompatibility
;
Genotype
;
Graft Survival
;
Humans
;
Immunoglobulin G
;
Immunoglobulin M
;
Kidney Transplantation
;
Kidney*
;
Tissue Donors*
;
Transplants
8.Study on Serological Blood Group Conversion in BM Empty Phase of ABO-incompatible Allogeneic Stem Cell Transplantation.
Xue-Jiao CAI ; Bi-Le CHEN ; Zuo-Ting XIE ; Yin-Cai YE
Journal of Experimental Hematology 2016;24(1):221-224
OBJECTIVETo explore the regularity of serological conversion of blood group in BM empty phase of ABO-incompatible allogeneic stem cell transplantation so as to provide the basis for selecting the blood components in blood transfusion.
METHODSBefore hematpoietic stem cell transplantation (HSCT), the ABO and RhD blood groups of recipients and donors were identified by salt medium tube method and microcolumn gel method; after transplantation the changes of antigen intensity and antibody titer of ABO blood group in patients were periodically detected.
RESULTSAfter blood group shift of 33 patients received ABO-incompatible allo-HSCT, the consistent rate of positive and regative types in major ABO incompatible group was 100%; the consistent rate of positive and negative types in minor ABO-incompatible group was 33%, no-consistent rate was 66.7%; the consistent rate of positive and negative types in bidirextional ABO incompatible group was 20%, the no-consistent rate was 80%.
CONCLUSIONAfter ABO-incompatible allo-HSCT, blood group antgen of patients shifts to the blood group of donors, there is a significant difference in the serological indicators between the minor and bidireetional ABO-incompatible patients and normal people.
ABO Blood-Group System ; Blood Group Incompatibility ; Blood Transfusion ; Hematopoietic Stem Cell Transplantation ; Humans ; Tissue Donors ; Transplantation, Homologous
9.A Case of Hemolytic Transfusion Reaction Attributable to Anti-Jk(b) Abolished in the Enzyme Phase Reaction.
Sae Am SONG ; Seung Hwan OH ; Ja Young LEE ; Sung Kyung SUNG ; Jeong Hwan SHIN ; Hye Ran KIM ; Kyung Ran JUN ; Jeong Nyeo LEE
Korean Journal of Blood Transfusion 2016;27(1):79-83
We report a case of an intravascular hemolytic reaction attributable to anti-Jk(b) antibodies that were not detected using an enzyme phase antibody identification test. A 61-year-old male who had received two units of red blood cells was admitted to the emergency room because his urine was dark. LISS/Coombs gel column agglutination tests suggested the presence of anti-Jk(b) and anti-E antibodies. However, his serum was negative for the Jk(b) antigen when an enzyme phase test was performed. A positive reaction was evident, however, when EDTA-treated plasma was tested; this excluded any possible complement-mediated reaction. The patient was diagnosed with an intravascular hemolytic transfusion reaction, caused by anti-Jk(b), and was later discharged without specific complications after receiving antigen-negative blood transfusions.
Agglutination Tests
;
Antibodies
;
Blood Group Incompatibility*
;
Blood Transfusion
;
Edetic Acid
;
Emergency Service, Hospital
;
Erythrocytes
;
Humans
;
Kidd Blood-Group System
;
Male
;
Middle Aged
;
Plasma
10.In vitro Quality Evaluation of Apheresis Platelets in Four Kinds of Platelet Additive Solutions.
Jaehyun KIM ; Jungwon KANG ; So Yong KWON ; Deok Ja OH
Korean Journal of Blood Transfusion 2016;27(1):55-67
BACKGROUND: Platelets (PLTs) stored in platelet additive solution (PAS) presents potential benefits in clinical use by reducing the risk of several plasma-associated adverse transfusion reactions and more plasma may be recovered for fractionation. In this study, we compared in vitro characteristics of apheresis PLTs stored in CompoSol PS (Fenwal, Lake Zurich, IL, USA), InterSol (Fenwal, Lake Zurich, IL, USA), SSP+ (MacoPharma, Tourcoing, France), T-PAS+ (Terumo BCT, Lakewood, CO, USA), or plasma to evaluate the effectiveness of PAS. METHODS: PLTs were collected two times by apheresis from 12 healthy volunteers in a study comparing four kinds of PASs with 35% autologous plasma and 100% plasma-stored apheresis PLTs. The parameters of PLTs, including PLT counts, pH, PLT activation markers, blood gases, and metabolic variables were assessed up to 7-day. RESULTS: The results of in vitro assay including PLT concentration, mean PLT volume, pH, and blood gases for PLTs in four kinds of PASs were similar to those in 100% plasma PLTs. All units had Day 5 pH greater than 6.2. In vitro quality rating results, PLTs in T-PAS+ had a rating of 5, 4 for CompoSol PS, 2 for SSP+, 1 for InterSol, and 2 for plasma on Day 5. CONCLUSION: Partial replacement of plasma with CompoSol PS, SSP+, or T-PAS+ in PLTs showed better or equivalent quality and preservability of PLTs compared to PLTs in 100% plasma. The use of PAS for storage of PLTs in clinical practice may have an advantage as PAS-stored PLTs have a reduced volume of plasma.
Blood Component Removal*
;
Blood Group Incompatibility
;
Blood Platelets*
;
Gases
;
Healthy Volunteers
;
Hydrogen-Ion Concentration
;
Lakes
;
Plasma

Result Analysis
Print
Save
E-mail