1.Clinical efficacy of Fu's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo and its effect on blood flow velocity of vertebral artery.
Meng GONG ; Zhixiang LIU ; Pei LI ; Renyan XIAO ; Peng JIA ; Hong GUO ; Song JIN
Chinese Acupuncture & Moxibustion 2025;45(1):13-18
OBJECTIVE:
To observe the clinical efficacy of Fu's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo (CV) and its effect on blood flow velocity of vertebral artery.
METHODS:
A total of 60 patients with CV were randomized into a Fu's subcutaneous needling group and a medication group, 30 cases in each one. In the Fu's subcutaneous needling group, Fu's subcutaneous needling was delivered at Dazhui (GV14), the flexible tube was retained for 5 min after sweeping manipulation, and the treatment was given once every other day, 3 times a week for 3 weeks. In the medication group, betahistine mesylate tablet and diclofenac sodium dual-release enteric capsule were taken orally for continuous 3 weeks. Before treatment, after treatment, and in follow-up of one month after treatment completion, the scores of dizziness handicap inventory (DHI) and visual analogue scale (VAS) were observed; before and after treatment, the blood flow velocity of vertebral artery was measured by transcranial Doppler, and the clinical efficacy was evaluated after treatment in the two groups.
RESULTS:
After treatment and in follow-up, each item scores and total scores of DHI were decreased compared with those before treatment in the two groups (P<0.05); the VAS scores after treatment in the two groups, as well as the VAS score in follow-up of the Fu's subcutaneous needling group, were decreased compared with those before treatment (P<0.05). In the Fu's subcutaneous needling group, after treatment and in follow-up, the physical scores and the total scores of DHI, and the VAS scores were lower than those in the medication group (P<0.05); in follow-up, the emotional and functional scores of DHI were lower than those in the medication group (P<0.05). After treatment, the mean blood flow velocity (Vm) of the left vertebral artery (LVA) and the right vertebral artery (RVA) was increased compared with that before treatment in the two groups (P<0.05), and the Vm of LVA and RVA in the Fu's subcutaneous needling group was higher than that in the medication group (P<0.05). The total effective rate was 100.0% (30/30) in the Fu's subcutaneous needling group, which was superior to 73.3% (22/30) in the medication group (P<0.05).
CONCLUSION
Fu's subcutaneous needling based on the "multi-joint muscle spiral balance chain" theory can effectively alleviate the vertigo and neck pain, and improve the blood flow velocity of vertebral artery in CV patients, and has a long-term therapeutic effect.
Humans
;
Female
;
Male
;
Middle Aged
;
Acupuncture Therapy/instrumentation*
;
Vertebral Artery/physiopathology*
;
Adult
;
Vertigo/physiopathology*
;
Aged
;
Blood Flow Velocity
;
Treatment Outcome
;
Acupuncture Points
;
Young Adult
2.Optimization of flow rate and orientation of outflow graft at implantation for patients with left ventricular assist device.
Yongyi WANG ; Li SHI ; Shijun HU ; Xiao TAN ; Tianli ZHAO
Journal of Central South University(Medical Sciences) 2025;50(3):457-468
OBJECTIVES:
A ventricular assist device (VAD) is an electromechanical device used to assist cardiac blood circulation, which can be employed for the treatment of end-stage heart failure and is most commonly placed in the left ventricle. Despite enhancing perfusion performance, the implantation of left ventricular assist device (LVAD) transforms the local intraventricular flow and thus may increase the risk of thrombogenesis. This study aims to investigate fluid-particle interactions and thromboembolic risk under different LVAD configurations using three-dimensional (3D) reconstruction models, focusing on the effects of outflow tract orientation and blood flow rates.
METHODS:
A patient-specific end-diastolic 3D reconstruction model was initially constructed in stereo lithography (STL) format using Mimics software based on CT images. Transient numerical simulations were performed to analyze fluid-particle interactions and thromboembolic risks for LVAD with varying outflow tract orientations under 2 flow rates (4 L/min and 5 L/min), using particles of uniform size (2 mm), and a blood flow rate optimization protocol was implemented for this patient.
RESULTS:
When the LVAD flow rate was 5 L/min, helicity and flow stagnation of the blood flow increased the particle residence time (RT) and the risk of thrombogenesis of the aortic root. The percentage of particles traveling toward the brachiocephalic trunk was up to 20.33%. When the LVAD flow rate was 4 L/min, blood turbulence in the aorta was reduced, the RT of blood particles was shortened, and then the percentage of particles traveling toward the brachiocephalic trunk decreased to 10.54%. When the LVAD blood flow rate was 5 L/min and the direction of the outflow pipe was optimal, the RT of blood particles was shortened, and then the percentage of particles traveling toward the brachiocephalic trunk decreased to 11.22%. A 18-month follow-up observation of the patient revealed that the LVAD was in good working order and the patient had no complications related to the implantation of LVAD.
CONCLUSIONS
Implantation of LVAD results in a higher risk of cerebral infarction; When implanting LVAD with the same outflow tract direction, optimizing flow velocity and outflow tract can reduce the risk of cerebral infarction occurrence.
Heart-Assist Devices/adverse effects*
;
Humans
;
Heart Failure/physiopathology*
;
Blood Flow Velocity
;
Thromboembolism/prevention & control*
;
Models, Cardiovascular
;
Heart Ventricles/physiopathology*
;
Imaging, Three-Dimensional
3.Quantitative analysis of the effect of contact pressure on the reflection characteristics of radial pressure wave.
Junyi TAN ; Lisheng XU ; Hongming SUN ; Bowen XU ; Yongchun LI ; Yudong YAO
Journal of Biomedical Engineering 2022;39(6):1127-1132
The radial artery pulse wave contains a wealth of physiological and pathological information about the human body, and non-invasive studies of the radial artery pulse wave can assess arterial vascular elasticity in different age groups.The piezoelectric pulse wave transducers were used to non-invasively acquire radial artery pulse waves at different contact pressures in young and middle-aged and elderly populations. The radial artery waveforms were decomposed using a triangular blood flow model fitting method to obtain forward and reflected waves and calculate reflection parameters. Finally a correlation analysis and regression analysis of the contact pressure Psensor with the reflection parameters was carried out. The results showed that the reflection parameters RM, RI and Rd had a strong negative correlation with Psensor in both types of subjects, and the correlation coefficients and slopes of the regression curves were significantly different between the two types of subjects (P<0.05). Based on the results of this study, excessive contact pressure on the transducer should be avoided when detecting radial artery reflection waves in clinical practice. The results also show that the magnitude of the slope of the regression curve between the reflection parameters and the transducer contact pressure may be a potentially useful indicator for quantifying the elastic properties of the vessel.
Middle Aged
;
Aged
;
Humans
;
Blood Pressure/physiology*
;
Arteries
;
Blood Flow Velocity/physiology*
;
Elasticity
;
Pulse Wave Analysis
;
Radial Artery/physiology*
4.Research on inversion method of intravascular blood flow velocity based on convolutional neural network.
Yuchen WANG ; Dan YANG ; Bin XU ; Xinyu ZHANG ; Xu WANG
Journal of Biomedical Engineering 2022;39(3):561-569
Blood velocity inversion based on magnetoelectric effect is helpful for the development of daily monitoring of vascular stenosis, but the accuracy of blood velocity inversion and imaging resolution still need to be improved. Therefore, a convolutional neural network (CNN) based inversion imaging method for intravascular blood flow velocity was proposed in this paper. Firstly, unsupervised learning CNN is constructed to extract weight matrix representation information to preprocess voltage data. Then the preprocessing results are input to supervised learning CNN, and the blood flow velocity value is output by nonlinear mapping. Finally, angiographic images are obtained. In this paper, the validity of the proposed method is verified by constructing data set. The results show that the correlation coefficients of blood velocity inversion in vessel location and stenosis test are 0.884 4 and 0.972 1, respectively. The above research shows that the proposed method can effectively reduce the information loss during the inversion process and improve the inversion accuracy and imaging resolution, which is expected to assist clinical diagnosis.
Angiography
;
Blood Flow Velocity
;
Constriction, Pathologic
;
Humans
;
Neural Networks, Computer
5.Effect of lower limb amputation level on aortic hemodynamics: a numerical study.
Junru WEI ; Zhongyou LI ; Junjie DIAO ; Xiao LI ; Lei MIN ; Wentao JIANG ; Fei YAN
Journal of Biomedical Engineering 2022;39(1):67-74
It has been found that the incidence of cardiovascular disease in patients with lower limb amputation is significantly higher than that in normal individuals, but the relationship between lower limb amputation and the episodes of cardiovascular disease has not been studied from the perspective of hemodynamics. In this paper, numerical simulation was used to study the effects of amputation on aortic hemodynamics by changing peripheral impedance and capacitance. The final results showed that after amputation, the aortic blood pressure increased, the time averaged wall shear stress of the infrarenal abdominal aorta decreased and the oscillatory shear index of the left and right sides was asymmetrically distributed, while the time averaged wall shear stress of the iliac artery decreased and the oscillatory shear index increased. The changes above were more significant with the increase of amputation level, which will result in a higher incidence of atherosclerosis and abdominal aortic aneurysm. These findings preliminarily revealed the influence of lower limb amputation on the occurrence of cardiovascular diseases, and provided theoretical guidance for the design of rehabilitation training and the optimization of cardiovascular diseases treatment.
Amputation
;
Aorta, Abdominal/surgery*
;
Aortic Aneurysm, Abdominal/surgery*
;
Blood Flow Velocity/physiology*
;
Hemodynamics/physiology*
;
Humans
;
Lower Extremity
;
Models, Cardiovascular
;
Stress, Mechanical
6.Signal Conversion and Isolation Processing Technology Used in the Cerebrovascular Stroke Detector.
Zengshui LIU ; Yudi CHEN ; Zhaobo PEI ; Jun FENG
Chinese Journal of Medical Instrumentation 2022;46(2):141-146
By using Doppler sensor and pressure sensor, the cerebrovascular stroke detector can be used to measure the blood flow velocity and blood pressure of the carotid artery. In this study, a variety of signal conversion and isolation processing techniques are proposed for processing and feature extraction of the output signals from the sensors. Finally, effective signal output waveforms that can be used to evaluate the cerebrovascular hemodynamics index (CVHI) are obtained, and the sound signal outputs that can reflect the change characteristics of blood flow velocity and blood pressure signals are generated, which realizes the application functional requirements of the detector.
Blood Flow Velocity/physiology*
;
Cerebrovascular Circulation/physiology*
;
Hemodynamics/physiology*
;
Humans
;
Stroke
;
Technology
7.Research Progress on Vector Flow Imaging of Cardiac Ultrasound.
Yigang DU ; Yongqiang DONG ; Dejie LIU ; Zhiwei SHI ; Yan WANG ; Xujin HE ; Lei ZHU
Chinese Journal of Medical Instrumentation 2022;46(2):176-180
Echocardiogram is vital for the diagnosis of cardiac disease. The heart has complex hemodynamics requiring an advanced ultrasound imaging mode. Cardiac ultrasound vector flow imaging is capable of measuring the actual magnitude and direction of the blood flow velocity, obtaining the quantitative parameters of hemodynamics, and then providing more information for clinical research and diagnosis. This study mainly reviewed several different vector flow imaging techniques for cardiac flow and presented the implementation difficulties, and proposed a diverging wave based high frame rate cardiac ultrasound vector flow imaging. The study discussed the limitation of current ultrasound technology used in the cardiac flow measurement, analyzed and demonstrated the specific reasons for these implementation difficulties and the potential future development.
Blood Flow Velocity
;
Heart/physiology*
;
Hemodynamics
;
Ultrasonography
8.Clinical value of TDI combined with 2D-STI on evaluating the microcirculation dysfunction and left ventricular dysfunction in patients with non-obstructive coronary angina.
Ting Ting LIU ; Ming Yan DING ; Dan Dan SUN ; Wei JI ; Hui Hui ZHANG ; Ying LI ; Li Juan GUO ; Fang ZHU
Chinese Journal of Cardiology 2021;49(12):1191-1197
Objective: To explore the value of tissue Doppler imaging (TDI) combined with two-dimensional speckle tracking imaging (2D-STI) at rest on evaluating microcirculation dysfunction and left ventricular dysfunction in patients with angina and no obstructive coronary artery disease(ANOCA). Methods: This retrospective study recruited 78 ANOCA patients, who hospitalized in the People's Hospital of Liaoning Province from August 2019 to July 2021. These patients underwent conventional echocardiography examination, including TDI and 2D-STI, to evaluate the left ventricular dysfunction, and adenosine stress echocardiography (SE) to evaluate the coronary flow velocity reserve (CFVR). ANOCA patients were divided into coronary microcirculation dysfunction CMD group (CFVR<2) and control group (CFVR≥2) according to CFVR. Clinical data, routine echocardiographic parameters, TDI parameters including isovolumic contraction time (IVCT), isovolumic relaxation time (IVRT), ejection time (ET), and STI parameters including global longitudinal peak strain (GLS), time to peak (TTP); peak strain dispersion (PSD) were compared between the two groups. Binary logistic regression was used to analyze the risk factors of CMD and the predictive value of each parameter to construct a joint prediction model for the diagnosis of CMD in this patient cohort. Results: The mean age was (55.5±11.2) years, 43 (55%) patients were females in this patient cohort, 38 (49%) patienst were didvided into the CMD group and 40 (51%) into the control group. Age, prevalence of hypertension, diabetes, dyslipidemia, and smokers were significantly higher in the CMD group than in the control group (all P<0.05). Tei index was higher, IVCT and TTP were longer, PSD was higher, ET was shorter, and absolute GLS was lower in the CMD group than in the control group (all P<0.05). The results of logistic regression analysis showed that longer IVCT, higher Tei index, higher time to PSD and lower absolute GLS were the independent risk factors of CMD. The ROC curve revealed that the predicting efficacy on CMD was satisfactiory with the combined predictors: AUC=0.884, sensitivity of 82% and specificity of 80%. Conclusions: TDI combined with 2D-STI is associated with a good diagnostic value on the diagnosis of CMD and left ventricular dysfunction in patients with ANOCA, which provides a feasible non-invasive tool for the diagnosis of CMD and risk stratification of patients with ANOCA.
Adult
;
Aged
;
Angina Pectoris
;
Blood Flow Velocity
;
Female
;
Humans
;
Microcirculation
;
Middle Aged
;
Retrospective Studies
;
Ventricular Dysfunction, Left/diagnostic imaging*
9.Development of a New Type of Atherosclerosis Detection Device.
Kejian DOU ; Jilun YE ; Xu ZHANG ; Junhan LUO
Chinese Journal of Medical Instrumentation 2020;44(4):311-314
This paper describes how to develop a practical new type of atherosclerosis detection device, which can realize real-time measurement and analysis of human atherosclerosis. According to the mechanism of human atherosclerosis, the design objectives of the system are formulated to determine the construction of the platform. The system calculates the pulse wave velocity by measuring the pulse wave of human fingers and toes, adds four blood pressure measurements to the system design, calculates the ankle-brachial index, and comprehensively measures and analyses the degree of human arteriosclerosis.
Ankle
;
Atherosclerosis
;
Blood Flow Velocity
;
Blood Pressure
;
Brachial Artery
;
Humans
;
Pulse Wave Analysis
10.Progress and Application Status of Arteriosclerosis Detection Methods.
Kejian DOU ; Jilun YE ; Xu ZHANG ; Maojie YUAN ; Jie LIU
Chinese Journal of Medical Instrumentation 2020;44(1):47-50
The study comprehensively puts forward several detection methods to arteriosclerosis and mainly discusses the method for pulse wave velocity (PWV for short) and ankle brachial index (ABI for short). On the basis of methods mentioned above, a portable system device for arteriosclerosis detection based on non-invasive PWV and limb blood pressure is introduced, and expectations for the subsequent engineering design and development direction are given for reference.
Ankle
;
Arteriosclerosis/diagnosis*
;
Blood Flow Velocity
;
Blood Pressure
;
Brachial Artery
;
Humans
;
Pulse Wave Analysis

Result Analysis
Print
Save
E-mail