Journal of Periodontal & Implant Science 2013;43(1):37-40
doi:10.5051/jpis.2013.43.1.37
Screening for diabetes mellitus using gingival crevicular blood with the help of a self-monitoring device.
Subodh GAIKWAD 1 ; Varsha JADHAV ; Abhijit GURAV ; Abhijeet R SHETE ; Hitesh M DEARDA
Affiliations
Keywords
Blood glucose self-monitoring; Diabetes mellitus; Gingival hemorrhage; Periodontal diseases
Country
Republic of Korea
Language
English
MeSH
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
Abstract
PURPOSE: The purpose of study was to compare blood glucose in capillary finger-prick blood and gingival crevice blood using a self-monitoring blood glucose device among patients with gingivitis or periodontitis. METHODS: Thirty patients with gingivitis or periodontitis and bleeding on probing (BOP) were chosen. The following clinical periodontal parameters were noted: probing depth, BOP, gingival bleeding index, and periodontal disease index. Blood samples were collected from gingival crevicular blood (GCB) and capillary finger-prick blood (CFB). These samples were analyzed using a glucose self-monitoring device. RESULTS: Descriptive statistical analysis has been carried out in the present study. Data were analyzed using a Pearson's correlation coefficient and Student's t-test. A r-value of 0.97 shows very strong correlation between CFB and GCB, which was statistically highly significant (P<0.0001). CONCLUSIONS: The authors conclude that GCB may serve as potential source of screening blood glucose during routine periodontal examination in populations with an unknown history of diabetes mellitus.
备案号: 11010502037788, 京ICP备10218182号-8)