Chinese Journal of Medical Instrumentation

2002 (v1, n1) to Present ISSN: 1671-8925

Articles

About

Year of publication

Save Email

Sort by

Best match
Relevance
PubYear
JournalTitle

DISPLAY OPTIONS

Format:

Per page:

Save citations to file

Selection:

Format:

Create file Cancel

Email citations

To:

Please check your email address first!

Selection:

Format:

Send email Cancel

2953

results

page

of 296

1

Cite

Cite

Copy

Share

Share

Copy

The application of operating room quality backward system in instrument place management.

Hui DU ; Anjie HE ; Leilei ZENG

Chinese Journal of Medical Instrumentation.2010;34(5):384-385.

OBJECTIVEImprovement of the surgery instrument's clean quality, the optimized preparation way, reasonable arrangement in groups, raising the working efficiency.

METHODWe use the quality backward system into the instrument clean, the pack and the preparation way's question, carry on the analysis and the optimization, and appraise the effect after trying out 6 months.

RESULTSAfter finally the way optimized, instrument clean quality distinct enhancement; The flaws in the instrument clean, the pack way and the total operating time reduce; the contradictory between nurses and the cleans arising from the unclear connection reduces, the satisfaction degree of nurse and doctor to the instrument enhances.

CONCLUSIONSUsing of operating room quality backward system in the management of the instrument clean, the pack and the preparation way optimized, may reduce flaws in the work and the waste of human resources, raise the working efficiency.


Materials Management, Hospital ; organization & administration ; Operating Rooms ; organization & administration ; standards ; Quality Control ; Software

Materials Management, Hospital ; organization & administration ; Operating Rooms ; organization & administration ; standards ; Quality Control ; Software

2

Cite

Cite

Copy

Share

Share

Copy

Optimization of doctor's order inputs interface and functions of electronic anamnesis.

Yang CAO ; Yan WANG

Chinese Journal of Medical Instrumentation.2010;34(5):381-383.

The doctor's order system of electronic anamnesis is the bridge between HIS system and a much better service, especially when the HIS system is focused on its billing function. In practice, we continuously perfect and better the interface and functions of medical advising inputs to effectively standardize doctors' orders and lessen mistakes. It can also enhance working efficiency, and set a valid platform for medical billing management, rationalized drug use management, antibiotic classification management, clinical application, etc.
Hospital Information Systems ; Medical Records Systems, Computerized ; Physician's Role

Hospital Information Systems ; Medical Records Systems, Computerized ; Physician's Role

3

Cite

Cite

Copy

Share

Share

Copy

Research on SOA for hospital information system.

Wei CHEN ; Min LIU

Chinese Journal of Medical Instrumentation.2010;34(5):378-380.

Integration of heterogeneous systems in hospital is an important subject. The loose-coupling and efficient data interaction can be realized with SOA, the complexity of cross-point can be avoided with ESB and Service-Oriented when system integration, the unified control can come for information management. Finally it will meet a variety of needs related with management and business in hospital, adapting quickly to changes.
Hospital Information Systems ; Integrated Advanced Information Management Systems

Hospital Information Systems ; Integrated Advanced Information Management Systems

4

Cite

Cite

Copy

Share

Share

Copy

Comparative study of device labeling regulation in U.S.A. and China.

Fei LI ; Jing WEI ; Yanbin MA ; Zhu LI

Chinese Journal of Medical Instrumentation.2010;34(5):374-377.

OBJECTIVETo provide references for the evolvement of medical devices labeling and manual administration in China,

METHODSBy content analysis, 10 juristic documents relevant to device labeling and manual were collected from FDA website, compared to which, the federal regulation was mainly analyzed.

RESULTSThere are five main differences of device labeling regulation between U.S.A. and China: juristic system, administrative scope, administrative target, characteristics and practice,

CONCLUSIONSA set of comprehensive juristic system for device labeling has been established by FDA. from which China should draw experience, to administrate the prescription devices and the over-the-counter devices in classification, and set up device labeling guidance, thus guarantee the safety and efficacy of device.


China ; Data Collection ; Device Approval ; legislation & jurisprudence ; Product Labeling ; legislation & jurisprudence ; Product Surveillance, Postmarketing ; United States ; United States Food and Drug Administration

China ; Data Collection ; Device Approval ; legislation & jurisprudence ; Product Labeling ; legislation & jurisprudence ; Product Surveillance, Postmarketing ; United States ; United States Food and Drug Administration

5

Cite

Cite

Copy

Share

Share

Copy

Testing of initial contamination for three kinds of surgical implants producted in Beijing.

Yang HU ; Yue ZHANG ; Jinhui HU

Chinese Journal of Medical Instrumentation.2010;34(5):370-373.

The initial contamination of femoral head, femoral stem and femoral component producted by seven factories in Beijing is tested, all of the initial contamination values are 580 in total. Then these data is analyzed on statistics. The result indicates that the initial contamination values of three kinds of products according with normal distribution; The initial contamination values have not significant difference between femoral head and femoral component of the same factory; and the season has not significant effect on initial contamination in Beijing. According to the experimental data, the level of initial contamination is undulatory, so the factories should control the initial contamination and maintain the stability of initial contamination.
Equipment Contamination ; prevention & control ; Prostheses and Implants ; classification ; microbiology ; Surgical Equipment ; classification ; microbiology

Equipment Contamination ; prevention & control ; Prostheses and Implants ; classification ; microbiology ; Surgical Equipment ; classification ; microbiology

6

Cite

Cite

Copy

Share

Share

Copy

Discussion on the determination of bicarbonate in hemodialysis.

Zhong LU ; Minju HUANG ; Zhixia CHEN

Chinese Journal of Medical Instrumentation.2010;34(5):368-369.

During the routine tests, it's found that the testing method related to Hemodialysis mentioned in the industry standard YY0598-2006 cannot reflect the real bicarbonate concentration in Hemodialysis. To discuss the reaction principle and its interference factors deeply by studying the assay determination of bicarbonate in Hemodialysis, and it could be cited as reference for amending the quality standard or troubleshooting. The improved way of determining bicarbonate concentration in Hemodialysis is also put up.
Bicarbonates ; analysis ; Dialysis Solutions ; analysis ; standards ; Renal Dialysis ; methods ; standards

Bicarbonates ; analysis ; Dialysis Solutions ; analysis ; standards ; Renal Dialysis ; methods ; standards

7

Cite

Cite

Copy

Share

Share

Copy

The electromagnetic compatibility test requirements for cardiac pacemaker in international standards.

Lei LIU ; Zhong GAO

Chinese Journal of Medical Instrumentation.2010;34(5):365-367.

Based on the latest international standards about implantable pacemakers, describing the main test requirements, especially for the EMC test requirements in details, and comparing the differences between the different standards, making readers having a clear understanding for the tests on pacemakers, especially for the EMC tests.
Calibration ; Electromagnetic Fields ; Pacemaker, Artificial ; standards

Calibration ; Electromagnetic Fields ; Pacemaker, Artificial ; standards

8

Cite

Cite

Copy

Share

Share

Copy

Comparison of the software safety evaluation methods in medical devices.

Sicong YU ; Ying PAN ; Xiping YU ; Yinfeng ZHU

Chinese Journal of Medical Instrumentation.2010;34(5):360-364.

The article intends to analyze the software safety problems in high-risk medical devices based on the investigation of software R & D Quality control procedures in Shanghai medical device manufacturing enterprises. The idea of improving the software pre-market safety evaluation method in China is also explored through the way of comparing those in U.S. and Europe.
China ; Equipment Safety ; methods ; Europe ; Quality Control ; Safety Management ; methods ; Software ; United States

China ; Equipment Safety ; methods ; Europe ; Quality Control ; Safety Management ; methods ; Software ; United States

9

Cite

Cite

Copy

Share

Share

Copy

The research progress on microelectrode array (MEA) of retinal prosthesis.

Tianao LI ; Zheng CAO ; Xiaohong SUI ; Xia JIANG ; Qiushi REN ; Xinyu CHAI

Chinese Journal of Medical Instrumentation.2010;34(5):355-359.

This review paper presents the current research progress, challenges and future development on microelectrode array of retinal prosthesis, including epi-retinal and sub-retinal implants.
Microelectrodes ; Prosthesis Design ; Visual Prosthesis

Microelectrodes ; Prosthesis Design ; Visual Prosthesis

10

Cite

Cite

Copy

Share

Share

Copy

Development on measuring method for the parameters of orthopaedic biomechanics.

Zhanshe GUO ; Yuanyong FANG ; Xangdang LIANG ; Geng SUN

Chinese Journal of Medical Instrumentation.2010;34(5):350-354.

This paper introduces the development on the research of measuring theory for orthopaedic biomechanics in detail. Then, the measuring method and corresponding measuring device are also mentioned. Advantages, disadvantages and development for the device are also introduced. Finally, the research prospect for it is introduced.
Biomechanical Phenomena ; Bone and Bones ; physiology ; physiopathology ; Physics ; instrumentation ; methods

Biomechanical Phenomena ; Bone and Bones ; physiology ; physiopathology ; Physics ; instrumentation ; methods

Country

China

Publisher

上海医疗器械检测所

ElectronicLinks

http://www.zgylqxzz.cn/

Editor-in-chief

E-mail

chjmi@263.net

Abbreviation

Chinese Journal of Medical Instrumentation

Vernacular Journal Title

中国医疗器械杂志

ISSN

1671-7104

EISSN

Year Approved

2013

Current Indexing Status

Currently Indexed

Start Year

1984

Description

1984-1988(3): 医疗器械; 1988(4)-:中国医疗器械杂志

Related Sites

WHO WPRO GIM

Help Accessibility
DCMS Web Policy
CJSS Privacy Policy

Powered by IMICAMS( 备案号: 11010502037788, 京ICP备10218182号-8)

Successfully copied to clipboard.