Korean Circulation Journal 1990;20(4):763-767
doi:10.4070/kcj.1990.20.4.763
The Evaluation of Position of Interventricular Septum Measured by Transitional Zone of EKG.
Young Koo JEE ; Keun Joong KIM ; Shin Bae JOO ; Moon Sung JUNG ; Won PARK ; Un Soo MOON ; Hong Soon LEE ; Hak Choong LEE
Country
Republic of Korea
Language
Korean
MeSH
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
Abstract
The position of interventricular septum, which was measured by transitional zone of EKG, was compared with that measured by 2-D echocardiography in 51 patient. 1) The position of interventricular septum measured by 2-D echocardiography was very similar to that measured by transitional zone of EKG. 2) Extensive AMI (Anterior Myocardial Infarction) and LBBB showed moderate differences between two method. 3) RBBB and replaced mitral valve state showed severe differences between two methods. Transitional zone of EKG was helpful to define the position of interventricular septum except extensive AMI, bundle branch block and replaced mitral valve state.