Chinese Journal of Endocrine Surgery 2019;13(5):393-396

doi:10.3760/cma.j.issn.1674-6090.2019.05.009

The application value of a simple stereotaxic technology in open biopsy of breast calcification with wire localization guided by X-ray

Songtao DING 1 ; Yi ZHANG ; Xiangjun MA ; Xiangping HE ; Yan LI ; Jing QIN

Affiliations

+expand

Keywords

Breast; Calcifications; Stereotaxic techniques; Biopsy

Country

China

Language

Chinese

Abstract

Objective To investigate the applicafion value of a simple stereotaxic technology in open biopsy of breast calcification with wire localization guided by X-ray.Methods 36 lesions in 30 cases with calcifications on mammography underwent X-ray guided simple wire stereotaxic localization open biopsy.Results 36 lesions in 30 cases were removed completely after wire localization,among which 24 cases were removed completely by one time,accounting for 80% (24/30)of the total,and 6 cases were removed completely by two times,accounting for 20% (6/30)of the total.No case were removed without calcification or removed completely by more than three times.Conclusion The simple stereotaxic technology in open biopsy of breast calcification with wire localization guided by X-ray is easy to learn and safe to do,which is suitable for promotion at the grassroots hospital.