Chinese Journal of Biochemical Pharmaceutics 2017;37(6):421-422
doi:10.3969/j.issn.1005-1678.2017.06.160
Predictive value of P wave dispersion on atrial arrhythmias
Yong ZHANG ; Xuhang HUA ; Jin LIU
Keywords
P wave dispersion; P wave maximum duration; atrial arrhythmia
Country
China
Language
Chinese
Abstract
Objective To explore the predictive value of P wave dispersion (Pd) and maximum P wave duration (Pmax) of 12 lead ECG in patients with atrial arrhythmia.Methods51 cases of atrial arrhythmia group from October 2013 to April 2015 in Jiashan County First People's Hospital, patients with frequent atrial premature atrial tachycardia, were examined for the determination of P wave dispersion by 12 lead electrocardiograms (Pd) and maximum P wave duration (Pmax), and 53 healthy persons (control group) were compared.ResultsAtrial arrhythmia group Pd and Pmax were significantly higher than the control group, the rate is Pmax=100ms with Pd=40ms high prediction of atrial arrhythmia sensitivity, specificity and diagnostic, Pd=40ms=100ms combined with Pmax diagnosis, the sensitivity increased, but the specificity and diagnostic rate of decline.ConclusionPd is an effective index to predict atrial arrhythmias, and the combined detection of Pd and Pmax can improve the diagnostic sensitivity.
备案号: 11010502037788, 京ICP备10218182号-8)