Recent Advances in Ophthalmology 2000;20(6):432-433
Hydroxyapatite orbital implant drilling and pegging
Zhengjun FAN ; Jianming QI
Keywords
orbital construction; hydroxyapatite; ocular prosthesis
Country
China
Language
Chinese
Abstract
Objective To evaluate the efficacy and safty of pegging hydroxyapatite orbital implants.Methods Fourty-five patients who received drilling and pegging of hydroxyapatite orbital implants were studied retrospectively, and all patients used the peg and sleeve system followed-up 2 to 24 months.Results The rate of success of the first operations is 82.2%. Complications associated with pegging included peg hole drilled on an angle, drilling off-center, drilled hole shallow, granuloma and infection, total complications occured in 22.2% in the review, most that are of a minor nature can be cured.Conclusions The hydroxyapatite orbital implants can be directly coupled to the prosthesis through a peg system, allowing a wide range of prosthesis movement and giving a more lifelike quality to the prosthesis. When and how to drill and exactly hole on implant is the key for pegging.
备案号: 11010502037788, 京ICP备10218182号-8)