Journal of Environment and Health 2001;18(2):115-116
Determination of Selenium in Hair by Hydride Generation Atomic Absorption Spectrophotometry
Huiqi LIU
Country
China
Language
Chinese
Abstract
The levels of selenium in hair were determined by hydride generation atomic absorption spectropho-tometryin this assay. The working conditions of the determination were controlled as follows,wavelength: 196.00 nm,working current of lamp:6 mA,wide of filtered spectrum:4.0 A, flow rate of gaseous argon: 120 ml/min. The averagecontents of selenium in hair samples reached 0. 0498±0. 031 mg/kg. The detection limit and coefficient of variation were0. 5 ng/ml and 5.8% respectively. The recovery rates were 92.0%~ 104. 0% with an average of 99. 5%. This methodshowed advantages ,such as simple operation,rapid,low cost and high accuracy. The obtained data were reliable.