Journal of Lung Cancer 2005;4(1):42-47
Effectiveness of Breath Hold with a ABC for SRS of Lung Cancer.
Young Eun KO 1 ; Seung Do AHN ; Byong Yong YI ; Sang Wook LEE ; Seong Soo SHIN ; Jong Hoon KIM ; Young Jo NOH ; Eun Kyung CHOI
Affiliations
Keywords
SRS; Whole body stereotactic frame; ABC
Country
Republic of Korea
Language
Korean
MeSH
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
Abstract
PURPOSE: It is very important to remove or to reduce the effect of organ motion due to respiration in stereotatic radiosurgery of lung. This study reports the effectiveness of the breath hold technique with a ABC for reducing the breathing effect. MATERIALS AND METHODS: Whole body stereotactic frame (Elekta, Sweden) was used for lung SRS. Patients who have tumor motion range larger than 10 mm from fluoroscopic observation were selected to apply a ABC. Seventeen patients were enrolled in this study. Passive breath hold is possible with our ABC. Automatic breath hold was set at 80% of deep inspiration. Breath hold time was 25~30 seconds depending on the patients. Three consecutive CT scans were performed as indicated in Asan Medical Center SRS procedure for each patients. Lung volume and PTV differences between with breath hold and free breath were examined for 5 patients. RESULTS: The breath hold technique with ABC could be applied for 15 patients. Inter-, intra-treatment organ motion with ABC showed 1.5 mm, while it was 2.3 mm with abdomen compress. When with breath hold technique, PTV and CTV was reduced 33.7% and 45.4%, respectively, and lung volume was increased 32.3 % compared to conventional SRS method. CONCLUSION: Better target localization could be achieved with breath hold technique in lung SRS. Tumor motion could be minimized and relative lung volume irradiation could be reduced
备案号: 11010502037788, 京ICP备10218182号-8)