Journal of the Korean Fracture Society 2012;25(2):136-141
doi:10.12671/jkfs.2012.25.2.136
Repeated Metal Breakage in a Femoral Shaft Fracture with Lateral Bowing: A Case Report.
Dong Soo KIM 1 ; Yong Min KIM ; Eui Sung CHOI ; Hyun Chul SHON ; Kyoung Jin PARK ; Byung Ki CHO ; Ji Kang PARK ; Hyun Cheol LEE ; Kyung Ho HONG
Affiliations
Keywords
Femur shaft fracture; Lateral bowing; Metal breakage; Locking compression plate; Intramedullary nail
Country
Republic of Korea
Language
Korean
MeSH
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
Abstract
Fractures of the femoral shaft with marked bowing face some obstacles in fixation of the fracture such as difficulty in insertion of the intramedullary nail (IM nail) or exact contouring plate. Locking compression plates (LCP) are an option to manage this problem. However, we experienced consecutive breakage of LCP twice and IM nail once in an 80-year-old female. Finally, union of the fracture was achieved after fixation of the IM nail and additional plate together. Fractures of the femur shaft with marked bowing are thought to have different biomechanical properties; therefore, we present this case with a review of the literature.