Journal of Yeungnam Medical Science 2024;41(2):96-102
doi:10.12701/jyms.2023.01228
Right anterior mini-thoracotomy aortic valve replacement versus transcatheter aortic valve implantation in octogenarians: a single-center retrospective study
Ji Eun IM 1 ; Eun Yeung JUNG ; Seok Soo LEE ; Ho-Ki MIN
Affiliations
Country
Republic of Korea
Language
English
Abstract
Background:The aim of this study was to compare the early outcomes of octogenarians undergoing minimally invasive right anterior mini-thoracotomy aortic valve replacement (RAT-AVR) with those undergoing transcatheter aortic valve implantation (TAVI) for aortic valve disease.
Methods:In this single-center retrospective study, data were collected from octogenarians before and after RAT-AVR and TAVI between January 2021 and July 2022. Short-term outcomes, including the length of hospital stay, in-hospital mortality, all-cause mortality, and other major postoperative complications, were compared and analyzed.
Results:There were no significant differences in in-hospital mortality, stroke, acute kidney dysfunction requiring renal replacement therapy, length of intensive care unit stay, or length of hospital stay. However, the TAVI group had a higher incidence of permanent pacemaker insertion (10% vs. 0%, p=0.54) and paravalvular leaks (75% vs. 0%, p<0.001).
Conclusion:In the present study on octogenarians, both TAVI and RAT-AVR showed comparable short-term results. Although both procedures were considered safe and effective in the selected group, RAT-AVR had a lower incidence of complete atrioventricular block and paravalvular regurgitation.