Drug Standards of China 2024;25(1):062-067
doi:10.19778/j.chp.2024.01.010
HPLC-RID method for the determination of glucosamine hydrochloride in amitriptyline enteric-coated tablets
YUAN Jinye ; CHEN Qi ; XUE Qiaoru ; CHEN Hua
Keywords
HPLC; RID; enteric-coated tablets of aspartame; glucosamine hydrochloride; content determination
Country
China
Language
Chinese
Abstract
Objective: To establish a method for the determination of glucosamine hydrochloride content in aminoglycine enteric coated tablets by high-performance liquid chromatography with differential refractive detector.
Methods: Waters XBridge Amide (4.6 mm×250 mm, 3.5 μm) column was used. The mobile phase was 80% acetonitrile solution (1 000 mL containing 1 mL ammonia) at the flow rate of 1.2 mL·min-1. Column temperature was set on 40 ℃; Injecting volume was 20 μL with differential refraction detector (RID) detection.
Results: The detection limit of glucosamine hydrochloride was 0.03 mg·mL-1, and the limit of quantification was 0.125 mg·mL-1. It showed a good linear relationship in the mass concentration range of 0.72-7.56 mg·mL-1. The average recovery was 99.4% (RSD=0.85%,n=9). The content of glucosamine hydrochloride in 7 batches of aminosamine enteric-coated tablets was measured in the range of 93%-107%.
Conclusion: The proposed method is fast, accurate, specific and durable, and can be used for the determination of glucosamine hydrochloride, which provides a reference for effectively controlling the quality of aminoxymetacin enteric-coated tablets.
备案号: 11010502037788, 京ICP备10218182号-8)