Drug Standards of China 2024;25(1):048-054
doi:10.19778/j.chp.2024.01.008
Simultaneous determination of four diterpene lactones in Lianzhi Xiaoyan capsules by QAMS
BI Fujun ; LU Qiaoyin ; LIN Tong
Keywords
Lianzhi Xiaoyan capsules; andrographolide; diterpene lactone; correction factor; QAMS; internal standard method
Country
China
Language
Chinese
Abstract
Objective: To set up a multi-components by single maker (QAMS) method for determination of four diterpene lactones in Lianzhi Xiaoyan capsules.
Methods: Shimadzu Shim-pack C18 column(250 mm×4.6 mm,5 μm)was adopted with 35 ℃. Acetonitrile-0.1% phosphoric acid aqueous solution as the mobile phase in gradient mode was used at flow rate of 1.0 mL·min-1. The detection wavelength was set at 203 nm. Andrographolide was used as reference to calculate the relative correction factors of the other three components.
Results: The linear relationships of four components were good (r≥0.999 9) within their ranges, and their average recoveries were 100.0%-102.8% with RSDs 1.1%-2.2%. The results obtained by QAMS were close to those obtained by external standard method.
Conclusion: This rapid, precise and reproducible method can be used for the quality control of Lianzhi Xiaoyan capsules.