Clinical Value of 1.5-T Non-contrast Whole-heart Magnetic Resonance Coronary Angiography in Evaluating the Severity of Coronary Stenosis.
- Author:
Lu LIN
1
;
Xiao-Na ZHANG
1
;
Hong LEI
2
;
Liang WANG
3
;
Zhu-Jun SHEN
3
;
Wei CHEN
2
;
Zhen-Jie WANG
2
;
Zheng-Yu JIN
1
;
Yi-Ning WANG
1
Author Information
- Publication Type:Journal Article
- Keywords: coronary angiography; coronary artery disease; diagnostic test; magnetic resonance angiography
- MeSH: Coronary Angiography; Coronary Stenosis/diagnostic imaging*; Humans; Magnetic Resonance Angiography; Magnetic Resonance Spectroscopy; Predictive Value of Tests; Sensitivity and Specificity
- From: Acta Academiae Medicinae Sinicae 2021;43(3):406-413
- CountryChina
- Language:Chinese
- Abstract: Objective To evaluate the diagnostic performance of 1.5-T non-contrast free-breathing whole-heart magnetic resonance coronary angiography(MRCA)for≥50% and≥70% coronary artery stenosis in coronary artery disease(CAD).Methods Forty-one patients clinically scheduled for invasive coronary angiography(ICA)underwent 1.5-T non-contrast free-breathing whole-heart MRCA.The diagnostic performance for≥50% and≥70% stenosis was evaluated and compared using ICA as a reference standard.Results MRCA was completed in all the 41 patients with the total acquisition time of(10.1 ± 2.2)min.The sensitivity,specificity,and accuracy of MRCA for≥50% and≥70% stenosis were 100%(95%