Massive Cerebral Microemboli after Protected Carotid Artery Angioplasty and Stenting Using a Distal Filter Embolic Protection Device for a Vulnerable Plaque with a Lipid Rich Necrotic Core and Intraplaque Hemorrhage: A Case Report
10.3348/jksr.2020.81.3.739
- Author:
Hae-Jung KIM
1
;
Myung-Ho RHO
Author Information
1. Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
- Publication Type:Case Report
- From:Journal of the Korean Radiological Society
2020;81(3):739-745
- CountryRepublic of Korea
- Language:English
-
Abstract:
A major concern associated with carotid artery angioplasty and stenting (CAS) is a periprocedural distal cerebral embolization. To prevent distal embolization, embolic protection devices (EPDs) have been developed. However, the risk of cerebral embolism after protected CAS in patents with a vulnerable plaque is controversial and either a silent or a symptomatic stroke can occur despite the use of EPDs. Here, we report a case of a massive cerebral microemboli after a protected CAS using a distal filter EPD for a vulnerable plaque with a lipid rich necrotic core and intraplaque hemorrhage.