Concurrent Occurrence of Type II and Type III Endoleak of Abdominal Aortic Aneurysm Stent Graft: A Case Report.
- Author:
Hyoung Su KIM
1
;
Seong Sook HONG
;
Jung Hoon KIM
;
Yong Jae KIM
;
Dong Erk GOO
;
Kui Hyang KWON
;
Deuk Lin CHOI
Author Information
1. Department of Radiology, Soonchunhyang University Hospital, Korea. hongses@hosp.sch.ac.kr
- Publication Type:Case Report
- Keywords:
Stents;
Endoluminal repair;
Aortic aneurysm, Abdominal;
Ultrasonography, Doppler
- MeSH:
Aged, 80 and over;
Angioplasty;
Aortic Aneurysm, Abdominal;
Endoleak;
Humans;
Renal Artery;
Stents;
Transplants;
Ultrasonography, Doppler
- From:Journal of the Korean Society of Medical Ultrasound
2009;28(4):281-284
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
Endoleak is an important complication following stent grafts for abdominal aortic aneurysms. Here we describe ultrasonography findings in an 86-year-old man including doppler ultrasonography and CT scan in an unusual and interesting case of the concurrent occurrence of a type II endoleak that originated from the left accessory renal artery and a type III endoleak due to shaft fracture of the stent.