Abstract:
BACKGROUND :Near-infrared (NIR) fluorescence imaging is one of the most useful diagnostic methods for breast cancer-related lymphedema (BCRL). It utilizes indocyanine green (ICG) lymphography, which requires a commercial camera that is not widely available. This study aimed to qualitatively assess the reliability of the modified NIR camera in diagnosing BCRL.
METHODS :This prospective cross-sectional study was conducted between December 2023 and December 2024 in breast cancer (BC) patients with BCRL. A commercial mirrorless digital camera was modified by incorporating an excitation light source and spectral filters to enable NIR imaging. To evaluate the camera reliability, intra- and inter-observer agreements were assessed using Kappa analysis. Three independent observers evaluated dermal backflow patterns of lymphatic flow: linear, splash, stardust, and diffuse patterns.
RESULTS :60 BC patients with BCRL resulting in 280 images were included. The mean (standard deviation) age was 54.7 (10.1) years and body mass index were 27.1 (4.5) kg/m². Most patients had stage IIA BC (40%) and stage IV ICG lymphography (38%). Intra-observer analysis showed observers 1 and 2 of had a Kappa of 1.00 (95% confidence interval [CI]: 1.00–1.00), while observer 3 had Kappa of 0.99 (95% CI: 0.97–1.00). Inter-observer analysis between observers 1 and 2 showed Kappa 1.00 (95% CI: 1.00–1.00), while observers 1–3 and 2–3 had Kappa of 0.99 (95% CI: 0.97–1.00). Observer 3 misinterpreted 3 linear as splash patterns.
CONCLUSIONS :This study showed a high inter- and intra-observer agreements making it reliable for BCRL diagnosis. - Full text:202611231144327732535-1-8234-Bayu-Brahma_xmp.pdf