Clinical efficacy and prognostic factors of type O universal blood products in emergency patients with blood loss and analysis
10.13303/j.cjbt.issn.1004-549x.2026.10.012
- VernacularTitle:O型通用型血液制剂在紧急失血患者中的临床疗效及预后影响因素分析
- Author:
Yu ZOU
1
;
Tianhua JIANG
1
;
Ling XIAO
1
;
Nanyin XIAO
1
;
Mao ZHENG
2
Author Information
1. Department of Blood Transfusion, Deyang People's Hospital, Deyang 618000, China
2. Department of Clinical Laboratory, Deyang People's Hospital, Deyang 618000, China
- Publication Type:Journal Article
- Keywords:
emergency transfusion;
group O universal blood products;
leukocyte-reduced suspended red blood cells;
low-titer whole blood;
short-term prognosis
- From:
Chinese Journal of Blood Transfusion
2026;39(10):1404-1412
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To systematically evaluate the clinical efficacy and safety of transfusing group O universal blood products (group O leukodepleted suspended red blood cells and low-titer group O whole blood) in patients with acute blood loss in emergency settings, and to explore factors associated with 24-hour prognosis through a comparison of different blood products and an analysis of risk factors for short-term prognosis. Methods: This single-center retrospective cohort study consecutively enrolled 65 patients with acute hemorrhage who received group O universal blood products at Deyang People's Hospital between January 2024 and December 2025. Baseline data, vital signs, laboratory parameters, transfusion timeliness data, and pre- and post-transfusion changes in parameters (Δ values) were collected. The t-test, Mann-Whitney U test, chi-square test, and Fisher's exact test were used for between-group comparisons, and a multivariate logistic regression model was used to analyze potential factors associated with prognosis Results: The 24-hour survival rate of the 65 patients was 76.9%. Analysis of baseline data indicated that the two groups were comparable, with a statistically significant difference only in blood type distribution (P=0.024); the proportion of patients with blood type A in the death group reached 66.7%. Post-transfusion analysis showed that APTT and D-dimer levels were significantly elevated in the death group (P<0.05), while serum calcium and potassium levels were significantly decreased (P<0.05). Notably, the low-titer whole blood group was significantly superior to the leukodepleted suspended red blood cell group in maintaining PT and INR stability (P<0.05). In exploratory multivariate logistic regression, ΔAPTT did not reach conventional statistical significance for association with 24hour mortality (OR=1.069, 95% CI 0.996-1.147, P=0.065), only suggesting a potential association and cannot be confirmed as an independent prognostic factor. No transfusion-related adverse reactions were observed in either group. Conclusion: This real-world observational study supports the favorable safety and efficacy of transfusing group O universal blood products in patients with emergency blood loss. Our data suggest that coagulation-fibrinolysis cascade disturbances and electrolyte imbalances may be associated with short-term outcomes. Low-titer whole blood showed certain advantages in maintaining coagulation homeostasis. Given the limitations of the single-center, small-sample design, these findings are exploratory and require further validation in larger cohorts.