A descriptive study on the occurrence of inadequate acoustic temporal bone window in transcranial doppler ultrasonography.
- Author:
Carter S. RABO
1
;
Jose C. NAVARRO
1
Author Information
- Publication Type:Journal Article, Original
- MeSH: Human; Ultrasonography, Doppler, Transcranial; Acoustics; Temporal Bone; Constriction, Pathologic
- From: Philippine Journal of Neurology 2007;11(2):43-43
- CountryPhilippines
-
Abstract:
BACKGROUND AND PURPOSE
Transcranial doppler ultrasonography is a useful tool in screening intracranial stenosis, but one of the major limitation of this procedure is the lack of a suitable acousric window. This study aims rn investigate the profile of patients with inadequate transtemporal window.
METHODOLOGYAll transcranial doppler studies done from June 2002 - May 2007 at a rertiary hospital were reviewed. They were then classified based on the following: 1) presence or absence oftranstemporal window; 2) sex; and 3) age (e"65 orRESULTS
233 out of the 1 ,028 patiems have poor acoustic window. 72% of chem were females and 67% of them were aged 65 and above.