Practice in Validity Period Management of Disinfectants, Feed, and Bedding in Laboratory Animal Facilities under Good Laboratory Practice Management System
10.12300/j.issn.1674-5817.2025.162
- VernacularTitle:GLP管理体系下实验动物设施消毒剂、饲料和垫料有效期管理实践
- Author:
Wenjing MA
1
;
Yanping LIU
1
;
Yifan LI
1
;
Huan GUO
1
;
Lihui XIE
1
;
Longji DU
1
;
Jiali MA
1
;
Hongping WANG
1
;
Jiamin LI
1
Author Information
1. Safety Evaluation Center, Sichuan Institute for Drug Control (Sichuan Testing Center of Medical Devices, Sichuan Institute of Musk Deer Breeding), Chengdu 611731, China
- Publication Type:Journal Article
- Keywords:
Good Laboratory Practice (GLP);
Disinfectant;
Feed;
Bedding;
Validity period;
Material management;
Laboratory animal
- From:
Laboratory Animal and Comparative Medicine
2026;46(4):593-603
- CountryChina
- Language:Chinese
-
Abstract:
ObjectiveTo meet the requirements of Good Laboratory Practice (GLP), Sichuan Institute for Drug Control (Sichuan Testing Center of Medical Devices, Sichuan Institute of Musk Deer Breeding) Safety Evaluation Center (hereinafter referred to as the center) conducts a targeted validation study to address the lack of supporting data for the specified validity periods of disinfectants, feed, and bedding during their use in laboratory animal facilities. The study summarizes practical experience in material management and provides a scientific basis for the standardized management of materials in the facility. MethodsUnder the routine operating conditions of the laboratory animal facility at the center, the disinfection efficacy of four commonly used disinfectants was confirmed using the quantitative suspension kill test, with the disinfectants tested on day 0, day 7, and at 1, 2, and 3 months after preparation and after opening; for laboratory animal feed, nutritional components, chemical contaminants, and microbial indicators were tested 7 days after opening; microbial indicators of laboratory animal corncob bedding were tested after storage for 7 days following opening and sterilization. ResultsUnder the GLP management system of our center, the disinfection efficacy log reduction values of prepared 0.04% sodium hypochlorite solution, 0.1% didecyldimethylammonium bromide solution, and 0.2% benzalkonium bromide solution were all ≥5 on days 0 and 7. The log reduction values of opened 75% ethanol were ≥5 on days 0 and 7 and at 1, 2, and 3 months after opening. All disinfectants were therefore qualified and effective. Compared with the factory inspection data, the nutritional components, chemical contaminants, and microbial indicators of SPF-grade rat and mouse maintenance feed, SPF-grade guinea pig growth and reproduction feed, conventional-grade guinea pig growth and reproduction feed, rabbit maintenance feed, and dog maintenance feed showed a slight overall downward trend but no significant differences 7 days after opening. The microbial indicators of specialized corncob bedding for SPF-grade laboratory animals stored for 7 days after opening and conventional-grade corncob bedding stored for 7 days after sterilization showed no significant fluctuations. All indicators still met the relevant requirements of GB/T 14924.2—2001 Laboratory Animals—Hygienic Standard for Formula Feeds and GB 14924.3—2010 Laboratory Animals—Nutrients for Formula Feeds. ConclusionBased on practical experience in managing the center's GLP laboratory animal facility and validation of core quality indicators, the specified validity periods of disinfectants, feed, and bedding meet the quality requirements, providing a practical reference for the standardized management of laboratory animal facilities.