Value of half-dose 18F-FDG deep-inhaled breath-hold total-body PET/CT in improvement of poor alignment of tumor lesions in thoracic and upper abdominal regions
10.3760/cma.j.cn321828-20240607-00198
- VernacularTitle:半剂量 18F-FDG深吸气屏气全身PET/CT在改善胸上腹肿瘤病灶对位不佳中的价值
- Author:
Jin JIA
1
;
Keqing YUAN
1
;
Meng LIU
1
;
Yingying HU
1
;
Wei FAN
1
;
Chao ZHOU
1
;
Weiguang ZHANG
1
Author Information
1. 中山大学肿瘤防治中心核医学科,广州 510060
- Publication Type:Journal Article
- Keywords:
Neoplasms;
Breath holding;
Positron-emission tomography;
Tomography, X-ray computed;
Fluorodeoxyglucose F18;
Low-dose
- From:
Chinese Journal of Nuclear Medicine and Molecular Imaging
2025;45(5):281-287
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the value of deep-inhaled breath-hold (DIBH)-30s scanning with total-body PET/CT under half-dose injection mode in improving the poor alignment of thoracic and upper abdominal tumors.Methods:Forty-six patients (28 males, 18 females, age (57.3±11.4) years) who underwent half-dose 18F-FDG total-body DIBH-30s PET/CT examination because of suspect or confirmed thoracic and upper abdominal tumors in Sun Yat-Sen University Cancer Center between October 2022 and February 2023 were analyzed retrospectively. SUV, standard deviation (SD) and signal-to-noise ratio (SNR) of the liver and mediastinal blood pool in free breath (FB)-8min, FB-30s and DIBH-30s PET images were measured; SUV of lesions, metabolic tumor volume (MTV) and tumor-to-background ratio (TBR) in DIBH-30s and FB-8min images were also measured; maximum diameter of contraposition offset and offset rate in coronal, transverse and sagittal directions of lesions in DIBH-30s and FB-8min images were calculated. Five-point Likert scale was used to score the overall image quality, image noise level and diagnostic confidence of fused images. Kruskal-Wallis rank sum test, Nemenyi test or Mann-Whitney U test was used to compare the parameters of different groups. Results:Among the 46 patients, 38 successfully completed breath-holding collection, and 80 lesions were detected, including 37 in the lungs and 43 in the livers. The liver SUV max (3.40(3.15, 3.63), 3.44(3.06, 3.70)) and SD (0.36(0.32, 0.41), 0.35(0.30, 0.40)) in DIBH-30s group and FB-30s group were higher than those (SUV max: 2.73(2.45, 2.92), SD: 0.15(0.13, 0.17)) in FB-8min group ( H values: 49.79, 85.27, χ2 values: 3.26-3.65, all P<0.001). The SUV max and the SD of mediastinal blood pool in DIBH-30s group and FB-30s group were also higher ( H values: 9.31, 59.73, χ2 values: 2.13-2.75, all P<0.01), while SNR liver and SNR med in those 2 groups were lower ( H values: 87.90, 54.11, χ2 values: 3.36-5.47, all P<0.001). The image noise scores of DIBH-30s group and FB-30s group were lower than the score of FB-8min group (3(3, 3) vs 3(3, 4) vs 5(5, 5); H=93.02, χ2 values: 2.13, 2.23, all P<0.001). The overall image quality score and diagnostic confidence score of DIBH-30s group were higher than those of FB-30s group and FB-8min group ( H values: 70.13, 24.22, χ2 values: 2.11-2.48, all P<0.001). The SUV and TBR of lesions in DIBH-30s group were higher than those of FB-8min group ( Z values: from -3.82 to -2.44, all P<0.05), while the MTV, contraposition offset and offset rate were lower than those of FB-8min group ( Z values: from -6.20 to -3.18, all P<0.001). Conclusions:DIBH-30s scanning with total-body PET/CT can make the focus alignment more accurate, which is suitable for short-time collection or low drug administration activity. It has a unique value in improving the poor focus alignment of chest and upper abdomen tumors.