Comparative efficacy of whole-process visualization system-assisted pedicle screw internal fixation and free-hand pedicle screw internal fixation in the treatment of thoracolumbar burst fracture without neurologic symptoms
10.3760/cma.j.cn501098-20241005-00587
- VernacularTitle:全程可视化系统辅助与徒手椎弓根螺钉内固定治疗无神经症状型胸腰椎爆裂骨折的疗效比较
- Author:
Wentao JIANG
1
;
Wei MEI
1
;
Qiangqiang PAN
1
;
Zhe SHAO
1
;
Peilin LIU
1
;
Zhenhui ZHANG
1
;
Kai SU
1
;
Yongsheng KANG
1
;
Qingde WANG
1
Author Information
1. 郑州市骨科医院脊柱骨科Ⅰ,郑州 450052
- Publication Type:Journal Article
- Keywords:
Spinal fractures;
Thoracic vertebrae;
Lumbar vertebrae;
Surgery, computer-assisted;
Visualization
- From:
Chinese Journal of Trauma
2025;41(2):157-163
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the efficacy of whole-process visualization system-assisted pedicle screw internal fixation and free-hand pedicle screw internal fixation in the treatment of thoracolumbar burst fracture (TLBF) without neurologic symptoms.Methods:A retrospective cohort study was conducted to analyze the clinical data of 64 patients with TLBF without neurologic symptoms admitted to Zhengzhou Orthopedic Hospital from December 2020 to October 2022, including 41 males and 23 females, aged 23-52 years [(42.1±6.6)years]. The injured vertebrae involved T 11 in 26 patients, T 12 in 17, L 1 in 12, and L 2 in 9. The Wiltse approach was used in all the patients, 31 of whom were treated with pedicle screw internal fixation assisted by the whole-process visualization system (visualization system-assisted screw placement group) and 33 of whom were treated with free-hand pedicle screw internal fixation (free-hand screw placement group). The two groups were compared in terms of operation time, single screw placement time, intraoperative blood loss, intraoperative total radiation dose and total length of hospital stay. The accuracy of pedicle screw placement and penetration rate of the pedicle cortex were evaluated in the two groups. The Cobb angle and lumbar visual analogue scale (VAS) before surgery, at 1 week, 3 months after surgery and at the last follow-up were compared between the two groups. The incidence of postoperative complications was also investigated. Results:All the patients were followed up for 10-33 months [(17.5±4.8)months]. The operation time was (106.9±11.8)minutes in the visualization system-assisted screw placement group, shorter than (121.3±11.4)minutes in the free-hand screw placement group ( P<0.01). The single screw placement time was (9.1±1.0)minutes in the visualization system-assisted screw placement group, shorter than (11.7±1.5)minutes in the free-hand screw placement group ( P<0.01). The total radiation dose was (10.4±2.4)mGy in the visualization system-assisted screw placement group, lower than (51.8±7.2)mGy in the screw placement group ( P<0.01). There was no significant difference in intraoperative blood loss or total length of hospital stay between the two groups ( P>0.05). The accuracy of pedicle screw placement was 96.6% (197/204) in the visualization system-assisted screw placement group, significantly higher than 89.3% (191/214) in the free-hand screw placement group ( P<0.01). Both groups showed significant improvements in Cobb angle and VAS scores at 1 week, 3 months after surgery, and at the last follow-up ( P<0.05). There were no significant differences in Cobb angle or VAS scores between the two groups at each time point ( P>0.05). In the visualization system-assisted screw placement group, one patient had incision infection at 4 days after operation, which was cured with antibiotics. One patient in the free-hand screw placement group developed the symptoms of nerve root irritation at 2 days after surgery, which disappeared at 7 days after revision. There was no significant difference in the incidence of complications between the two groups ( P>0.05). During the follow-up, no patients had broken screws, loosening of internal fixation, or loss of correction in either group. Conclusions:Compared with free-hand pedicle screw internal fixation, the whole-process visualization system-assisted pedicle screw internal fixation in the treatment of TLBF without neurologic symptoms can shorten the time of operation and screw placement, reduce the radiation dose, and improve the accuracy of pedicle screw placement, suggesting that it is a safer and more effective auxiliary method for pedicle screw placement.