Efficacy of reduction robot system combined with minimally invasive, microenvironmental protection, micro-stress shielding fixator in the treatment of Sanders types II and III calcaneal fractures
10.3760/cma.j.cn501098-20250101-00001
- VernacularTitle:复位机器人系统联合三微固定器治疗Sanders Ⅱ、Ⅲ型跟骨骨折的疗效
- Author:
Xiaohui HAO
1
;
Yongqing WANG
;
Zhanmin XU
;
Xinan ZHANG
;
Zhihui ZHAO
;
Jingtao SUN
;
Zhiqiang YANG
;
Meiyue LIU
;
Weiyong WU
;
Baoxi HAO
;
Juwen CHEN
Author Information
1. 天津医科大学附属第四中心医院骨科,天津 300140
- Publication Type:Journal Article
- Keywords:
Calcaneus;
Robotics;
Fractures, bone;
Surgical procedures, minimally invasive;
Fracture microenvironment
- From:
Chinese Journal of Trauma
2025;41(5):463-470
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the efficacy of reduction robot system combined with minimally invasive, microenvironmental protection, micro-stress shielding fixator (short for "3M fixator") for Sanders types II and III calcaneal fractures.Methods:A retrospective case series study was conducted to analyze the clinical data of 26 patients (26 feet) with calcaneal fractures admitted to Fourth Affiliated Central Hospital of Tianjin Medical University from June 2022 to June 2024, including 21 males and 5 females, aged 27-69 years [(46.5±2.5)years]. Among them, 10 patients had fractures in the left foot and 16 in the right. According to the Sanders classification, the fractures were classified as type II in 16 patients and type III in 10. All the patients were treated with the close reduction with reduction robot system combined with 3M fixator in a minimally invasive procedure. The surgical waiting time, operative duration, and fracture healing time were recorded. The length, width and height of the calcaneus, B?hler′s angle and Gissane′s angle were compared before operation and at 1, 3 months after operation. The visual analogue scale (VAS) and American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score before operation and at 1, 3 months after operation and at the last follow-up were detected. The postoperative complications were recorded.Results:All the patients were followed up for 6-12 months [(9.7±1.1)months]. The surgical waiting time was 1-4 days [(2.0±0.8)days]. The operative duration was 36-66 minutes [(53.2±9.5)minutes]. All the fractures achieved primary union with a healing period of 3-4 months [(3.2±0.4)months]. At 1, 3 months after operation, the length of the calcaneus [(83.3±3.7)mm and (83.6±3.6)mm], width of the calcaneus [(44.3±5.8)mm and (44.3±5.7)mm], height of the calcaneus [(50.1±3.8)mm and (50.3±3.6)mm], B?hler′s angle [(29.8±2.9)° and (29.8±3.0)°], and Gissane angle [(121.1±6.7)° and (123.9±5.9)°] were significantly improved compared with those before operation [(79.3±4.5)mm, (53.6±4.1)mm, (46.2±3.7)mm, (18.9±3.8)°, (109.0±7.5)°, respectively] ( P<0.05), with no significant differences between those indicators at 1, 3 months after operation ( P>0.05). The VAS scores were (3.2±0.6)points, (1.9±0.5)points, and (1.6±0.3)points at 1, 3 months after operation and at the last follow-up, which were lower than (7.1±0.5)points preoperatively and decreased with the prolongation of follow-up time ( P<0.05). The AOFAS scores were (73.5±6.9)points, (90.1±4.3)points, and (92.0±3.6)points, which were higher than (32.0±4.6)points preoperatively and increased with the follow-up time ( P<0.05). One patient had lateral calcaneal pain after operation, and was alleviated after rehabilitation. No complications such as infection or nonunion were found after operation. Conclusion:The reduction robot system combined with 3M fixator for Sanders types II and III calcaneal fractures demonstrates significant clinical advantages, such as reduced surgical waiting time and operative duration, promoted fracture healing, early alleviated pain, enhanced ankle joint functional recovery, and decreased complication occurrence.