Comparative efficacy of robot-assisted balloon tibioplasty and traditional open reduction and internal fixation in the treatment of AO/OTA type 41B2 tibial plateau fracture
10.3760/cma.j.cn501098-20241213-00699
- VernacularTitle:机器人辅助下球囊胫骨成形术与传统开放复位内固定术治疗AO/OTA 41B2型胫骨平台骨折的疗效比较
- Author:
Jialang HU
1
;
Jing JIAO
;
Yucheng HUANG
;
Wen XIONG
;
Jinyi WU
;
Hai DENG
;
Zhihua GENG
;
Xuan MA
;
Ming CHEN
Author Information
1. 武汉市第四医院创伤骨科,武汉 430030
- Publication Type:Journal Article
- Keywords:
Tibial fractures;
Robotics;
Open fracture reduction
- From:
Chinese Journal of Trauma
2025;41(4):369-376
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the clinical efficacy of robot-assisted balloon tibioplasty and traditional open reduction and internal fixation in the treatment of AO/OTA type 41B2 tibial plateau fracture.Methods:A retrospective cohort study was conducted to analyze the clinical data of 70 patients with AO/OTA type 41B2 tibial plateau fracture who were admitted to Wuhan Fourth Hospital from September 2019 to October 2022, including 35 males and 35 females, aged 24-62 years [(44.9±9.5)years]. Among them, 41 patients underwent traditional open reduction and internal fixation (open reduction group), while 29 patients underwent robot-assisted balloon tibioplasty (balloon group). The following parameters were compared between the two groups: incision length, operative blood loss, number of intraoperative fluoroscopies, operation duration, and length of hospital stay; Rasmussen radiological scores at 3 days, 3 months postoperatively, and at the last follow-up and the fracture healing time; pain visual analogue scale (VAS) scores preoperatively, and at 2 days and 3 months postoperatively; knee joint range of motion at 5 days, 3 months postoperatively, and at the last follow-up; Hospital for Special Surgery (HSS) knee function scores at 3, 6 months postoperatively, and at the last follow-up; incidence rate of complications at 15 days postoperatively.Results:All the patients were followed for 12-24 months [18(17, 20)months]. The incision length, operative blood loss and length of hospital stay in the balloon group were 1.6(1.5, 3.0)cm, 5.0(5.0, 5.0)ml and 11.0(9.0, 14.0)days, less than those in the open reduction group [12.0(11.0, 12.0)cm, 100.0(50.0, 120.0)ml and 15.0(13.0, 20.0)days] ( P<0.01). The number of intraoperative fluoroscopies and operation duration in the open reduction group were 9.0(7.0, 10.0)times and 75.0(60.0, 90.0)minutes, less than those in the balloon group [336.0(335.0, 340.0)times and [90.0(70.0, 105.0)minutes] ( P<0.05). There were no significant differences in the Rasmussen radiological scores between the two groups at 3 days, 3 months postoperatively, or at the last follow-up ( P>0.05). The fracture healing time in the balloon group was 3.0(3.0, 3.0)months, shorter than 3.0(3.0, 3.5)months in the open reduction group ( P<0.05). No significant differences were observed between the two groups in VAS scores before operation or at 3 months postoperatively ( P>0.05). However, the VAS score was 2.0(2.0, 3.0)points at 2 days postoperatively in the balloon group, lower than 5.0(5.0, 6.0)points in the open reduction group ( P<0.01). The knee joint range of motion at 5 days, 3 months postoperatively and at the last follow-up were 90.0(85.0, 90.0)°, 135.0(130.0, 135.0)° and 140.0(135.0, 140.0)° in the balloon group, better than 65.0(60.0, 70.0)°, 125.0(120.0, 130.0)°, 130.0(130.0, 140.0)° in the open reduction group ( P<0.01). Similarly, the HSS knee function scores at 3, 6 months postoperatively and at the last follow-up were 80.0(80.0, 81.0)points, 91.0(90.0, 92.0)points, and 95.0(93.0, 96.0)points in the balloon group, better than 71.0(70.0, 72.0)points, 83.0(81.0, 84.0)points, and 86.0(84.0, 88.0)points in the open reduction group ( P<0.01). The incidence rate of complications in the balloon group was 0, comparable to 12% (5/41) in the open reduction group ( P>0.05). Conclusion:Compared with traditional open reduction and internal fixation surgery, robot-assisted balloon tibioplasty in the treatment of AO/OTA type 41B2 tibial plateau fracture significantly reduces surgical trauma, alleviates postoperative pain, promotes fracture healing, and accelerates functional recovery of the affected limbs.