The effectiveness and safety of a fully biodegradable occluder for the treatment of ventricular septal defects through percutaneous and transthoracic surgical approaches
10.3760/cma.j.cn101070-20241106-00726
- VernacularTitle:完全生物可降解封堵器经皮和经胸途径治疗室间隔缺损的手术策略及有效性和安全性
- Author:
Siyang FAN
1
;
Liyun ZHAO
;
Bin LI
;
Juan CONG
;
Chongyang YAN
;
Yuhang CAO
;
Guangyuan SONG
;
Shubo SONG
Author Information
1. 首都医科大学附属北京安贞医院心脏瓣膜病介入中心,北京 100029
- Publication Type:Journal Article
- Keywords:
Ventricular septal defect;
Biodegradable occluder;
Percutaneous approach;
Transthoracic approach;
Clinical study
- From:
Chinese Journal of Applied Clinical Pediatrics
2025;40(7):509-514
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To analyze the efficacy and safety of a fully biodegradable occluder for the treatment of ventricular septal defects through percutaneous and transthoracic strategies.Methods:A case series study was conducted.The clinical data of 38 pediatric patients with a ventricular septal defect treated with a fully biodegradable occluder at Central China Fuwai Hospital from January 2023 to July 2024 were retrospectively analyzed.Among these patients, 15 received the percutaneous approach(percutaneous approach group) and the other 23 adopted the transthoracic approach(transthoracic approach group).The diagnosis was confirmed by transthoracic echocardiography before operation in all patients.The percutaneous approach was defined as establishing a venous-arterial track through X-ray and then placing an occluder under the guidance of transthoracic echocardiograph.The transthoracic approach was achieved by establishing a delivery track with a special hollow bougie through a small right subaxillary incision under the real-time guidance of esophageal ultrasound and then delivery and put an occluder.The clinical data of the patients, including general characteristics, electrocardiograms, echocardiograms and the biodegradable occluder system were collected and analyzed.Categorical variables were tested using the chi-square or Fisher′s exact test.Continuous variables were verified using the t-test or Mann-Whitney U test. Results:The patients were aged (5.7±3.9) years on average, with an average weight of 19.5(14.9, 25.9) kg.There were 39.5%(15 cases) of males among the patients included.The average size of the ventricular septal defect was 4.1(4.0, 5.0) mm.A simple perimembrane ventricular septal defect was detected in 29 patients (76.3%), concomitant membranous aneurysm in 4 patients (10.5%), an intracristal ventricular septal defect in 3 patients (7.9%), and a muscular ventricular septal defect in 2 patients (5.3%).Preoperative aortic and tricuspid valve regurgitations accounted for 5.3%(2/38) and 81.6%(31/38), respectively.The average age was (9.0±3.9) years in the percutaneous approach group and (3.6±1.9) years in the transthoracic approach group.In terms of the cardiac structure, the percutaneous approach group had smaller Z values of the left atrial anterior-to-posterior diameter (-0.5±0.6 vs.0.5±1.0, P<0.01) and the left ventricular end-diastolic diameter (-0.5±1.1 vs.0.8±0.8, P<0.01), and a smaller ventricular septal defect [4.0(3.9, 4.2) mm vs.4.5(4.0, 5.5) mm, P=0.01] than the transthoracic approach group.Regarding the operation, the percutaneous approach group had a larger difference between the waist diameter of the selected occluder and the diameter of the ventricular septal defect [2.8(2.0, 3.0) mm vs.2.0(1.5, 2.5) mm, P=0.02], shorter operative time [(61.5±27.3) minutes vs.(91.5±31.4) minutes, P=0.01], and a shorter hospital stay [8(5, 9) days vs.12(9, 15) days, P<0.01] than the transthoracic approach group.Both groups achieved immediate occlusion postoperatively, with no residual shunts and no grade Ⅲ atrioventricular conduction block.Five new cases of bundle branch blocks and 1 case of trivial aortic valve regurgitation occurred in the transthoracic approach group. Conclusions:Both percutaneous and transthoracic approaches are safe and effective in interventional closure of ventricular septal defects, but the former is more applicable to slightly older or heavier patients with a smaller ventricular septal defect, who need a larger occluder.