Analysis for the value of digital mammography combined with serum CHAC1 and RAI14 in differentiating benign and malignant breast masses
10.3969/j.issn.1672-8270.2025.03.008
- VernacularTitle:数字乳腺断层X射线成像联合血清CHAC1和RAI14在鉴别乳腺肿块良恶性中的价值分析
- Author:
Limin YAO
1
;
Jianxia HUANG
;
Hongrui FAN
;
Jingjuan DONG
;
Wenzheng DU
;
Xiaoxiao LIAN
Author Information
1. 邯郸市妇幼保健院影像二科 邯郸 056001
- Publication Type:Journal Article
- Keywords:
Digital mammography;
Glutathione specific gamma-glutamyl transpeptidase 1(CHAC1);
Retinoic acid-induced protein 14(RAI14);
Breast mass differentiation
- From:
China Medical Equipment
2025;22(3):43-47
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the diagnostic value of digital mammography combined with serum glutathione specific gamma-glutamyl transpeptidase 1(CHAC1)and retinoic acid-induced protein 14(RAI14)in identifying benign and malignant breast masses.Methods:A total of 189 patients with breast masses who were treated at Handan Maternal and Child Health Care Hospital from June 2019 to June 2024 were prospectively selected as the research subjects.According to the results of pathological biopsy,they were divided into benign mass group(128 cases)and malignant mass group(61 cases).All patients underwent digital mammography detection.The levels of serum CHAC1 and RAI14 were detected by enzyme-linked immunosorbent assay(ELISA).The general clinical data of the patients were collected and analyzed.Multivariate logistic regression analysis was used to analyze the factors of influencing benign and malignant nature of breast masses.The receiver operating characteristic(ROC)curve was drawn to analyze the diagnostic value of CHAC1 and RAI14 for the benign and malignant nature of breast masses.The Kappa test was used to assess the consistency of results between each diagnostic method and the pathological detection.Results:For 189 patients with breast masses,digital mammography identified 56 cases of malignant masses and 133 cases of benign masses,and 13 cases of them were misdiagnosis and 18 cases of them were missed diagnosis.It showed a moderate consistency with the results of pathological detection(Kappa=0.617,P<0.05).Compared with the benign mass group,the levels of serum CHAC1 and RAI14 in the malignant mass group were significantly higher,and the differences of them between the two groups were statistically significant(t=12.249,12.512,P<0.05).The age,menopausal time,CHAC1 and RAI14 of the patients were all risk factors that can affect the benign and malignant nature of breast masses(OR=1.368,1.305,1.897,1.995,P<0.05).The area under curve(AUC),sensitivity and specificity of CHAC1 were respectively 0.816(95%CI:0.753~0.868),70.49%and 89.06%in diagnosing the benign and malignant nature of breast masses.These indicators of RAI14 were respectively 0.838(95%CI:0.778~0.888),68.85%and 89.84%in diagnosing the benign and malignant nature.The combined detection of the three methods identified 74 cases of malignant masses and 115 cases of benign masses,with 15 cases of misdiagnosis and 2 cases of missed diagnosis,which showed an extremely high consistency with the results of pathological detection(Kappa=0.805,P<0.001).The sensitivity(96.72%),negative predictive value(98.26%)and accuracy(91.01%)of the combined detection of digital mammography,serum CHAC1 and RAI14 were significantly higher than those of each alone detection of them,and the differences of them were significant(x2=15.310,16.623,15.310,11.690,12.402,11.572,5.276,5.276,4.677,P<0.05).Conclusion:The levels of serum CHAC1 and RAI14 appear increase in malignant breast masses,and digital mammography combined with serum CHAC1 and RAI14 has a certain of identification value for benign and malignant nature of breast masses.