Design and application of one piece temperature controlled enema device
10.3760/cma.j.cn211501-20240823-02294
- VernacularTitle:一体式温控灌肠装置的设计与应用
- Author:
Yu LI
1
;
Huiyang SUN
;
Yanjiang LIU
;
Tong JIN
;
Ze LI
;
Yan BAI
Author Information
1. 吉林省肿瘤医院护理部,长春 130000
- Publication Type:Journal Article
- Keywords:
Enema;
Equipment design;
Nursing care
- From:
Chinese Journal of Practical Nursing
2025;41(17):1290-1295
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To design a safe and convenient temperature-controlled enema device and to verify its effectiveness in enema operation.Methods:This study was a quasi experimental research. A total of 60 patients who were hospitalized in Jilin Provincial Cancer Hospital from October 2023 to January 2024 were selected as the control group, and 60 patients who underwent enema from February to May 2024 were selected as the experimental group adopting convenience sampling method. The control group used traditional enema operation method, while the experimental group used an integrated temperature controlled enema device for enema operation. The heating time of enema solution, retention time of enema solution in the intestine, patient satisfaction rate, and nursing staff satisfaction rate were compared between the two groups before enema operation.Results:There were 39 males and 21 females in the control group, aged (54.78 ± 10.66) years, and 42 males and18 females in the experimental group, aged (56.15 ± 9.88) years. The warming time of enema fluid in the experimental group was 17.00 (15.25, 18.00) s, which was lower than 55.00 (47.00, 59.75) s in the control group, and the difference was statistically significant ( Z = - 9.47, P<0.01). The intraintestinal retention time of enema fluid in the experimental group was 9.50 (9.00, 10.00) min, which was greater than 7.00 (6.00, 8.75) min in the control group, and the difference was statistically significant ( Z = - 7.93, P<0.01); the satisfaction rate of the experimental group was 96.67% (58/60), which was higher than 73.33% (44/60) in the control group, and the difference was statistically significant ( χ2 = 12.81, P<0.01); the satisfaction rate of the nursing staff in the experimental group was 96.00% (48/50), which was higher than 66.00% (33/50) in the control group, and the difference was statistically significant ( χ2 = 14.62, P<0.01). Conclusions:The integrated temperature-controlled enema device reduces the tediousness of nursing operation. It improves the rate of complete preparation of goods, patient satisfaction and nursing staff satisfaction, thereby ensuring efficacy and patient safety.