Analysis of short-term efficacy of drug-coated balloon in the treatment of atherosclerotic renal artery stenosis
10.3969/j.issn.1002-1671.2025.09.026
- VernacularTitle:药物涂层球囊治疗动脉粥样硬化性肾动脉狭窄的短期疗效分析
- Author:
Haozhe ZHANG
1
;
Qiongfang CHANG
1
;
Juanfang LIU
1
;
Xinwei HAN
1
;
Jianhao ZHANG
1
Author Information
1. 郑州大学第一附属医院放射介入科,河南 郑州 450052
- Publication Type:Journal Article
- Keywords:
drug-coated balloon;
renal artery stenosis;
atherosclerosis
- From:
Journal of Practical Radiology
2025;41(9):1541-1544
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the feasibility,safety and efficacy of paclitaxel drug-coated balloon(DCB)in the treatment of atherosclerotic renal artery stenosis(ARAS).Methods A total of 28 patients with ARAS were selected.Balloon angioplasty was performed using a paclitaxel DCB at the site of renal artery stenosis(RAS)in these patients.Subsequently,a follow-up study was conducted to monitor various parameters of the patients,including vascular restenosis,blood pressure,the types of antihypertensive medications and renal function.The feasibility,efficacy and safety of balloon angioplasty using DCB in the treatment of ARAS were analyzed.Results Twenty-eight patients underwent 33 DCB balloon angioplasty.In one patient,there was no significant improve-ment in the degree of RAS,and thus further treatment with renal artery stenting was administered.The remaining patients all achieved both anatomical and hemodynamic success,with the degree of vascular stenosis at the lesion site decreasing from(79.74±5.13)%to(8.32±4.67)%,and the surgical success rate was 96.97%.The systolic/diastolic blood pressure of the patients was(179.16±30.65)mmHg/(108.26±20.93)mmHg(1 mmHg=0.133 kPa)at 24 hours postoperatively,(131.11±12.99)mmHg/(80.11±7.12)mmHg at 3 months postoperatively,(134.16±11.37)mmHg/(78.68±4.79)mmHg at 6 months postoperatively,and(133.37±12.71)mmHg/(80.11±4.84)mmHg at 12 months postoperatively.In comparison with the preoperative blood pressure of(184.63±27.64)mmHg/(109.11±22.26)mmHg,there was no significant decrease in blood pressure at 24 hours postoperatively,and the difference was not statistically significant.However,at 3,6,and 12 months postoperatively,the patients'blood pressure was signif-icantly lower than that before the operation,and all the differences were statistically significant.The glomerular filtration rate(GFR)was(36.19±18.32)mL/min at 24 hours postoperatively,(35.96±18.51)mL/min at 3 months postoperatively,(36.23±19.30)mL/min at 6 months postoperatively,and(35.59±18.26)mL//min at 12 months postoperatively,which all elevated compared with the preoperative GFR of(28.31±14.67)mL/min,and the differences were statistically significant(P<0.05).At 3,6,and 12 months postoperatively,the vascular patency rate was 100%as indicated by multifunctional color Doppler ultrasound examination or renal artery computed tomography angiography(CTA).No relevant com-plications and postoperative adverse events,such as renal artery rupture or dissection,renal artery thrombosis and acute renal insuffi-ciency,occurred in all 28 patients.Conclusion The paclitaxel DCB is safe and reliable for the treatment of ARAS and has remarkable curative effects,and it can be used as an effective vascular treatment regimen for ARAS.