Quantitative Evaluation of Mitral Valve Structure and Function in Mitral Valve Prolapse by Three-Dimensional Transesophageal Echocardiography
10.3969/j.issn.1005-5185.2025.08.010
- VernacularTitle:经食管三维超声心动图定量评估二尖瓣脱垂患者二尖瓣结构及功能
- Author:
Jinlong ZHONG
1
;
Juan XIA
;
Xiaojing MA
;
Huiying CHEN
Author Information
1. 武汉科技大学附属武汉亚洲心脏病医院超声科,武汉心血管影像学临床医学研究中心,湖北 武汉 430065;武汉科技大学医学院,湖北 武汉 430022
- Publication Type:Journal Article
- Keywords:
Mitral valve prolapse;
Echocardiography,three-dimensional;
Foramen ovale,patent;
Mitral valve configuration
- From:
Chinese Journal of Medical Imaging
2025;33(8):854-861
- CountryChina
- Language:Chinese
-
Abstract:
Purpose To evaluate the static structural changes of mitral annulus and leaflets in mitral valve prolapse via three-dimensional transesophageal echocardiography(3D-TEE),and their continuous dynamic changes during the cardiac cycle.Materials and Methods Twenty-six patients with mitral valve prolapse diagnosed by transesophageal echocardiography in Wuhan Asia Heart Hospital from June 2022 to June 2023 were retrospectively included,and 30 patients who were examined by transesophageal echocardiography in our hospital during the same period due to monitoring of patent foramen ovale or non-cardiac surgery were selected as the control group.The related parameters of the valve annulus were measured.In addition,the meaningful parameters were measured at late diastole(LD),early systole(ES),middle systole(MS)and late systole(LS),and the change rate was calculated.The static structure of mitral valve device was compared between the two groups,and the differences of various parameters at different times were analyzed.Results Compared with the control group,the annulus height(AH)and the ratio of annulus height and combined width(AHCWR)in the case group decreased,and the other parameters increased(t=-7.447-12.472,all P<0.05),but there was no statistical difference in the maximum displacement distance of the annulus between the two groups(P>0.05).Comparing the related parameters of LD,ES,MS and LS at four different time points,compared with the control group,all the parameters in the case group increased except AH and AHCWR(t=-16.224-15.683,all P<0.05).Comparing the continuous changes at four different times,the continuous changes of all parameters in the control group were statistically significant(F=7.632-323.837,all P<0.05),and there were significant differences in the parameters of the control group from LD to ES(all P<0.05).Except anterolateral to posteromedial diameter,intertrigonal diameter and annulus area,the continuous changes of other parameters in the case group were statistically significant(F=3.041-71.082,all P<0.05),and only non-planar angle,AH and AHCWR in the case group had statistical differences in LD to ES(all P<0.05).Compared with the control group,the change rate of parameters in the case group decreased,and the difference was statistically significant(t/U=-7.069-780.000,all P<0.05),and the change rate of C-ring was greater than that of intertrigonal diameter.Conclusion 3D-TEE can quantitatively analyze the dynamic changes of mitral annulus and leaflets,and analyze the continuous changes of mitral valve in cardiac cycle in detail,which can provide more accurate preoperative evaluation for patients and guide treatment.