The efficacy of individualized endovascular interventional treatment for extracranial carotid artery pseudoaneurysms
10.3760/cma.j.cn112149-20250418-00209
- VernacularTitle:个体化血管内介入治疗颈动脉颅外段假性动脉瘤的疗效
- Author:
Tengfei LI
1
;
Chengcheng SHI
1
;
Sun YU
1
;
Ji MA
1
;
Ling WANG
1
;
Quanhui ZHANG
1
;
Xinwei HAN
1
Author Information
1. 郑州大学第一附属医院放射介入科,郑州 450052
- Publication Type:Journal Article
- Keywords:
Aneurysm, false;
Carotid arteries;
Radiology, interventional;
Stents
- From:
Chinese Journal of Radiology
2025;59(6):712-718
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the efficacy and safety of different endovascular interventional treatments for extracranial carotid artery pseudoaneurysms.Method:The clinical data of 48 patients with extracranial carotid artery pseudoaneurysms treated with multiple endovascular procedures were retrospectively analyzed in the First Affiliated Hospital of Zhengzhou University from February 2012 to February 2024. The patients presented with a total of 48 extracranial carotid pseudoaneurysms, ranging in diameter from 2.5 to 34.2 mm [mean (12.0±9.6) mm]. The lesions were distributed as follows: 25 in the internal carotid artery, 16 in the external carotid artery and 7 in the common carotid artery. The selection of endovascular interventional techniques was tailored to individual cases according to the pseudoaneurysm size, anatomical location, morphological configuration, and specific features of the parent artery. Perioperative adverse events were monitored, and the efficacy of individualized endovascular interventional therapy was evaluated based on immediate postoperative and 6-month follow-up digital subtraction angiography (DSA) findings, including aneurysm occlusion and in-stent patency.Result:The treatment modalities included parent artery coiling occlusion ( n=16), overlapping braided carotid stent implantation ( n=3), covered stent placement ( n=23), combined implantation of covered stent and braided carotid stent implantation ( n=4) and flow-diverting stent implantation ( n=2) based on the characteristics of the pseudoaneurysms. Endovascular interventional procedures were successfully completed in 47 patients (technical success rate: 97.9%). Immediate postoperative DSA revealed residual pseudoaneurysm at the distal end of the stent in 1 case. Among the remaining cases, complete aneurysm obliteration or faint opacification was observed, with stent lumen patency confirmed in 31 cases and complete parent artery occlusion achieved in 16 cases. In one case involving a patient who underwent flow-diverting stent implantation, a pulsatile vascular murmur reappeared in the neck one week postoperatively. Follow-up DSA revealed stent migration into the aneurysm sac. After retrieval and removal of the displaced stent, combined implantation of a covered stent and a braided carotid artery stent was performed. Postoperative angiography confirmed complete aneurysm occlusion and patent parent artery blood flow. No severe perioperative adverse events (e.g., aneurysm rupture) were observed. During a postoperative follow-up period of 6.2-24.2 months, DSA at 6 months revealed mild in-stent or distal segment stenosis in 2 patients who underwent covered stent implantation. The remaining 46 patients exhibited complete aneurysm occlusion with no significant stenosis observed within the stent lumen. At the final follow-up, all patients demonstrated resolution or significant alleviation of clinical symptoms. Conclusion:Individualized endovascular interventional therapy demonstrates favorable safety and efficacy profiles in managing extracranial carotid artery pseudoaneurysms.