Transesophageal echocardiography guided transcatheter edge-to-edge repair led to esophageal erosion:one case report
10.3969/j.issn.1004-8812.2025.06.010
- VernacularTitle:经食管超声心动图引导经导管缘对缘修复术导致食管糜烂1例
- Author:
Bo ZHANG
1
;
Ning WANG
;
Yan FENG
;
Wen-bin OUYANG
;
Jian-bin GAO
Author Information
1. 云南省阜外心血管病医院 昆明医科大学附属心血管医院结构性心脏病中心,云南 昆明 650102
- Publication Type:Journal Article
- Keywords:
Mitral regurgitation;
Transesophageal echocardiography;
Erosion;
Edge-to-edge repair
- From:
Chinese Journal of Interventional Cardiology
2025;33(6):358-360
- CountryChina
- Language:Chinese
-
Abstract:
Transcatheter edge-to-edge repair has become the most important and widely recognized method for the treatment of patients with severe mitral regurgitation who are at high risk for surgery.At present,TEER is developing rapidly in China,the operation process tends to be standardized and standardized,and various domestic Clip devices are also constantly developing and improving,but the operation process of this technology is very dependent on the guidance and monitoring of transesophageal echocardiography,and many surgeons often only pay attention to the repair effect of TEER on MR,and ignore the damage of TEE probe to the esophagus.This study reports a case of esophageal erosion occurring in a patient after mitral valve clipping for mitral regurgitation,aiming to enhance awareness among colleagues regarding esophageal injury caused by transesophageal echocardiography probes.