Effect of IDream reconstruction technique based on iterative reconstruction algorithm on image quality of low-dose CT on upper abdomen and the displays of hepatic cyst
10.3969/j.issn.1672-8270.2025.01.003
- VernacularTitle:基于迭代重建算法的IDream重建技术对低剂量上腹部CT图像质量及肝囊肿显示的影响
- Author:
Peng YE
1
;
Huayang DU
;
Zhengjun LI
;
Man WANG
;
Yun WANG
;
Yukun LIANG
;
Jie FANG
Author Information
1. 安康市中心医院医学放射影像中心 安康 725000
- Publication Type:Journal Article
- Keywords:
IDream reconstruction technique;
Computed tomography (CT);
Hepatic cyst;
Image quality
- From:
China Medical Equipment
2025;22(1):13-18
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the optimal reconstruction grade of IDream reconstruction technique in reducing image noise,optimizing image quality,and displaying liver cysts through the subjective assessment on the display of computed tomography (CT) image with differently reconstructive grades in IDream reconstruction technique of iterative reconstruction algorithm,and the objective evaluation of image quality of upper abdomen. Methods:The imaging data of CT plain scan of 53 patients with hepatic cysts who underwent plain scans on upper abdomen at Peking Union Medical College Hospital from August to September 2021 were retrospectively collected. All images were reconstructed to standard window images by using 6 kinds of methods that included filtered back projection (FBP) and IDream grades 1 to 5,which resulted in 6 groups of images that included FBP group and IDream grades 1-5. The CT values and standard deviation (SD) values of the liver,abdominal aorta,erector spine muscle,fat and spleen in images of each group were measured and recorded,respectively. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the images were calculated. Two CT diagnostic physicians with more than 8 years of experience conducted subjective scoring for the display in the images of hepatic cysts of each group. The objective parameters and the subjective scores of hepatic cysts of reconstructive images with different grades were compared. A one-way analysis of variance was adopted to analyze the objective parameters,and Kruskal-Wallis H test was conducted on the subjective score of the display of hepatic cysts. Results:There were no statistically significant differences in the CT values among different reconstruction grades on the liver,abdominal aorta,fat,erector spine muscle and spleen (P>0.05). In the FBP group and IDream grades 1 to 5 groups,the SD values of images gradually decreased with the increasing of the reconstruction grades,which were respectively (18.11±5.03),(15.37±4.97),(13.26±4.83),(11.68±4.56),(10.99±4.36) and (10.60±4.21) Hu. The SNR and CNR of the liver gradually increased. The differences in SD values,SNR,and CNR among the six groups of images were all statistically significant (F=20.75,17.72,3.15,P<0.05),respectively. The subjective scores for the display of hepatic cysts from the FBP group to IDream grades 1 to 4 were respectively (3.12±0.35),(3.63±0.46),(4.02±0.42),(4.61±0.48) and (4.63±0.48),which were gradually increasing,while the score for the IDream grade 5 group slightly decreased to (4.53±0.47). The subjective scores for hepatic cysts in the images of IDream grades 3 and 4 groups were the highest. The comparison of the average subjective scores of the images of hepatic cysts among the six reconstruction grades showed statistically significant differences (H=192.17,P<0.05). Conclusion:In CT plain scan on the upper abdomen,with the increasing of IDream reconstruction grades,the image noises gradually decrease,and objective parameters of images gradually enhance,and the reconstructions of IDream grades 3 and 4 can obtain the optimal image quality of upper abdomen at the objective score of hepatic cysts.