Self-made improved cone beam CT fixation components for maxillofacial scanning
10.13929/j.issn.1003-3289.2025.09.027
- VernacularTitle:自制改良锥形束CT固位组件用于颌面部扫描
- Author:
Anqi LIU
1
;
Antian GAO
1
;
Shu LIU
1
;
Zitong LIN
1
Author Information
1. 南京大学医学院附属口腔医院,南京市口腔医院,南京大学口腔医学研究所口腔颌面医学影像科,江苏南京 210008
- Publication Type:Journal Article
- Keywords:
oral medicine;
cone beam computed tomography;
artifacts;
retention
- From:
Chinese Journal of Medical Imaging Technology
2025;41(9):1582-1585
- CountryChina
- Language:Chinese
-
Abstract:
Objective To observe the value of self-made improved cone-beam CT(CBCT)fixation components for maxillofacial scanning.Methods CBCT fixation components(chin rest,temporal clamp)equipped by Planmeca ProMax 3D Mid dental panoramic X-ray system were modified to obtain improved CBCT fixation components,including improved chin rest,temporal clamp and occipital retention band.Totally 571 patients who underwent maxillofacial CBCT examinations for dental-related diseases were retrospectively enrolled,including 288 cases(group A)underwent scanning by a junior technician using original chin rest+original temporal clamp(component 1,n=78,A1 subgroup),modified chin rest+original temporal clamp(component 2,n=74,A2 subgroup),original chin rest+original temporal clamp+occipital retention band(component 3,n=68,A3 subgroup)or modified chin rest+original temporal clamp+occipital retention band(component 4,n=68,A4 subgroup),while the rest 283 cases(group B)underwent scanning by a senior using the above components,respectively,and were taken as B1(n=72),B2(n=69),B3(n=73)and B4(n=69)subgroups.The incidence of motion artifacts were compared among A2/B2,A3/B3,A4/B4 subgroups and A1/B1 subgroups.Results Compared with A1+B1 subgroups,the overall motion artifacts rate in A4+B4 subgroups decreased from 17.33%(26/150)to 8.03%(11/137)(P=0.019),while in A2+B2 subgroups(13.29%[19/143])and A3+B3 subgroups(9.93%[14/141])did not significantly decrease(P=0.337,0.067).In group A,no statistical difference of motion artifacts rate was found between A 2(17.57%[13/74])or A3(13.24%[9/68])subgroups and A1 subgroup(23.08%[18/78])(P=0.399,0.127),while the motion artifacts rate in A4 subgroup(10.29%[7/68])was lower than that in A1 subgroup(23.08%[18/78])(P=0.041).In group B,no significant difference of motion artifacts rates was found between B2,B3 or B4 subgroups(8.70%[6/69],6.85%[5/73],5.80%[4/69])and B1 subgroup(11.11%[8/72])(P=0.632,0.369,0.258).Conclusion Self-made improved CBCT fixation components could effectively secure patients' head and reduce motion artifacts in maxillofacial CBCT.