Influence of CECT on online dose calculation of adaptive MRgRT for rectal cancer
10.3969/j.issn.1672-8270.2025.10.004
- VernacularTitle:增强CT对直肠癌核磁引导自适应放射治疗在线计划剂量计算的影响
- Author:
Shaojuan WU
1
;
Jing CHEN
1
;
Baolong NIU
1
;
Liang JIN
1
;
Peichao BAN
1
;
Xiangkun DAI
1
;
Chuanbin XIE
1
Author Information
1. 中国人民解放军总医院第一医学中心放射治疗科 北京 100853
- Publication Type:Journal Article
- Keywords:
Rectal cancer;
Magnetic resonance imaging(MRI)-guided radiotherapy;
Online adaption;
Contrast-enhanced computed tomography(CECT)
- From:
China Medical Equipment
2025;22(10):20-25
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the influence of contrast-enhanced computed tomography(CECT)on dose calculation in magnetic resonance imaging(MRI)-guided online adaptive radiotherapy(oART)based on the electron density(ED)assignment method for rectal cancer.Methods:A retrospective analysis was conducted on the medical data of 15 patients with locally advanced rectal cancer at middle-low segments,who admitted to the Chinese PLA General Hospital between December 2023 and April 2025.All patients underwent both plain computed tomography(PCT)and CECT scans during location.The average HU and ED value of all organs that were extracted from PCT and CECT images in the treatment plan system were obtained,and the influences of contrast agent of intake on image characteristics of the structure of each organ(small intestine,femoral head,bladder)were analyzed.PCT was used as referred image to design reference plan(Pref).The synthetic CT(sCT)was simulated and generated on the basis of PCT and CECT,respectively.The beam flow field that was same with Pref was used to recalculate dose on sCT,and then,the online plan(PPCT)based on PCT,and the online plan(PCECT)based on CECT were obtained,respectively,which can simulate the online dose calculation of MRI-guided online adaptive radiotherapy(oART).The Pref was used as reference to compare dosimetric parameters for target region and organ at risk(OAR)through dose volume histogram(DVH)and planed evaluation indicators.Additionally,three dimension(3D)slicer software was used to perform γ analysis for the results of dose distribution,and explore the differences among PPCT,PCECT and Pref on dose distribution.Results:In terms of image characteristics,the HU values of soft-tissue organs(intestine,bladder,spinal cord,soft tissue)and planning target volume(PTV)in CECT were higher than those in PCT,and the differences of them were statistically significant(Zintestines=-2.188,Zbladder=-3.196,tspinal cord=-3.767,tsoft tissue=-10.083,tPTV=-4.693,P<0.05),while its influence was less on bone tissue.The statistical results of ED were consistent with those of HU.Regarding to dosimetric parameters,there was no statistically significant difference in target coverage rate between PPCT and Pref(P>0.05),and the D50%of the PPCT[(2724.25±19.91)cGy]was higher than that of the Pref[(2718.99±21.13)cGy],and the difference was statistically significant(t=-3.679,P=0.002).However,the target coverage rate of PCECT was 94.65(94.04,95.27)%,and the difference of that between PCECT and Pref was statistically significant(Z=-2.158,P=0.031).For OAR,the differences of Dmax value of the small intestine,and the V20 of the left femoral head between PPCT and Pref were significant(Z=-2.556,-2.529,P<0.05).The differences of the Dmax of small intestine,and the D50%of bladder between PCECT and Pref were significant(t=-4.821,2.171,P<0.05).The comparative γ passed rates of PPCT,PCECT and Pref under the standards of 3 mm/3%and 2 mm/2%were all above 95%,and the differences were not significant(P>0.05).Conclusions:The influence of CECT on dose calculation in MRI-guided oART based on ED assignment method for rectal cancer is relatively small,which can be directly used in the design of reference plan,but the maximum dose of radiation-sensitive organs such as the small intestine should be paid attention.