Dosimetric comparison of 4 different volumetric modulated arc therapy plans for hippocampal-sparing prophylactic cranial irradiation
10.3969/j.issn.1005-202X.2025.07.003
- VernacularTitle:海马体保护预防性全脑照射中4种容积旋转调强放疗计划的剂量学对比研究
- Author:
Meijiao WANG
1
;
Jiacheng LIU
1
;
Kaining YAO
1
;
Yichen PU
1
;
Jian GONG
1
;
Fan JIANG
1
;
Yi DU
1
Author Information
1. 北京大学肿瘤医院暨北京市肿瘤防治研究所放疗科/恶性肿瘤发病机制及转化研究教育部重点实验室,北京 100142
- Publication Type:Journal Article
- Keywords:
hippocampal-sparing;
prophylactic cranial irradiation;
volumetric modulated arc therapy
- From:
Chinese Journal of Medical Physics
2025;42(7):853-862
- CountryChina
- Language:Chinese
-
Abstract:
Objective To quantitatively compare the dosimetric differences among 4 volumetric modulated arc therapy(VMAT)plans by analyzing the number of arcs and collimator angle settings,aiming to establish a standardized planning template for hippocampal-sparing prophylactic cranial irradiation(HS-PCI)in clinic and improve both planning quality and clinical efficiency.Methods Twenty HS-PCI patients were enrolled,with 4 VMAT plans(V2c,V2p,V3,and V4)for each patient.The differences in target dose,organs-at-risk dose,and monitor units were compared.Results V4 plan had the highest PTV D98%and V95%,and the differences of PTV D98%in V2c vs V2p,V2c vs V4,and PTV V95%in V2c vs V4 were statistically significant(P<0.05).Meanwhile,V4 plan had the lowest PTV Dmax and Dmin doses.Specifically,statistically significant differences were observed in PTV Dmax in V4 vs V2c,V4 vs V2p,V4 vs V3,as well as PTV Dmin in V2c vs V2p,V2c vs V3,V2c vs V4,V2p vs V4(P<0.05).The PTV Dmean was the highest in V2p plan,with statistically significant differences observed in V2c vs V2p,V2c vs V4,V2p vs V3,and V3 vs V4(P<0.05).The highest PTV D2%dose was observed in V2p plan,and the differences in V2c vs V2p,V2c vs V4,V2p vs V3,V3 vs V4 were statistically significant(P<0.05).The homogeneity index and conformity index were close in 4 plans(P=0.946,P=0.380).V4 plan had the lowest Dmax,Dmean,and Dmin of the hippocampus,with significant differences in hippocampal Dmax in V4 vs V2c,V4 vs V2p,hippocampal Dmean in V4 vs V2c,V4 vs V2p,V3 vs V2c,and hippocampal Dmin in V2c vs V2p/V3/V4,and V4 vs V2p(P<0.05).V3 plan had the lowest Dmax for bilateral lenses,and V4 plan showed the lowest Dmax for lenses with a 3 mm expansion,with significant differences between V2c and V2p/V3/V4(P<0.05).V4 plan had the lowest dose for the right optic nerve,with significant differences in V4 vs V2p,and V4 vs V3(P<0.05).No significant differences were observed for the left optic nerve and optic chiasm.The monitor units in V2p plan was the lowest.Conclusion When differences in organs-at-risk doses and plan quality parameters are insignificant,V2p plan is recommended as it can ensure treatment quality while reducing delivery time.