Arthroscopic suture anchor fixation for acute bony Bankart lesions: excellent bone healing with a low complication rate
10.3760/cma.j.cn121113-20250213-00136
- VernacularTitle:肩关节镜下带线锚钉固定治疗急性骨性Bankart损伤
- Author:
Qiangqiang LI
1
;
Peng SUN
;
Yu ZHANG
;
Kai FU
;
Yao YAO
;
Jianghui QIN
;
Jin XIONG
;
Qing JIANG
;
Dongyang CHEN
Author Information
1. 南京大学医学院附属鼓楼医院运动医学与成人重建外科,南京 210008
- Publication Type:Journal Article
- Keywords:
Shoulder joint;
Bankart lesions;
Arthroscopy;
Suture anchor
- From:
Chinese Journal of Orthopaedics
2025;45(8):523-530
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the clinical outcomes of arthroscopic suture anchor fixation for acute bony Bankart lesions.Methods:Data of 49 patients with acute bone Bankart injury treated with suture anchor fixation under arthroscopy at the Affiliate Nanjing Drum Tower Hospital of Nanjing University School of Medicine from February 2019 to July 2024 were retrospectively analyzed, including 34 males and 15 females, aged 46.4±17.7 years (range, 18-81 years). Body mass index was 26.3±4.2 kg/m 2 (range, 19.8-37.9 kg/m 2). There were 17 patients with left shoulder and 32 patients with right shoulder. The time from injury to operation was 12.6±10.5 d (range, 1-50 d). CT three-dimensional reconstruction showed that the area of bone defect accounted for 20.1%±11.4% (range, 8%-49%) of the glenoid area. According to the degree of bone defect, there were 38 cases in the bone defect area ≤25% group and 11 cases in the bone defect area >25% group. All 49 patients received shoulder arthroscopic fixation with wire anchor. All 49 the patients were treated under shoulder arthroscopy using suture anchor technique. Using American Shoulder & Elbow Surgeon (ASES) score, University of California, Los Angeles (UCLA) score, Rowe score as well as shoulder range of motion to evaluate shoulder function. The position and healing of the fracture mass were evaluated with shoulder joint CT and three-dimensional reconstruction at immediate and final follow-up. Results:The incision healed in one stage and no infection occurred in all patients. All 49 patients were followed up for a period of 3 to 81 months, with an average follow-up of 23.8±20.2 months. At the final follow-up, the mean forward elevation, external rotation, and internal rotation improved from 126.1°±20.3°, 36.9°±14.0°, and 10±2 preoperatively to 167.1°±15.5°, 66.8°±8.3°, and 6±1 at the last follow-up, respectively ( P<0.05). At the final follow-up, the mean ASES score, UCLA score, and Rowe score were all significantly improved from 41.3±11.9, 14.2±6.1 and 46.9±14.7 preoperatively to 89.7±7.8, 31.5±3.6 and 92.4±7.4, respectively ( P<0.05). The differences between the final follow-up and preoperative values for forward elevation in the bone defect area >25% group and the bone defect area ≤25% group were 43°±20° and 41°±21°, respectively. The differences in lateral external rotation were 34°±8° and 29°±18°, while the differences in internal rotation (measured by hand-behind-back reach) were 5±2 and 4±2, respectively. None of these differences were statistically significant. The differences between the final follow-up and preoperative scores in the bone defect area >25% fracture fragment group and the bone defect area ≤25% group were as follows: ASES score, 50.9±14.4 vs. 47.7±12.8; UCLA score, 18.4±3.2 vs. 17.0±6.9; and Rowe score, 40.5±13.5 vs. 46.9±15.0. None of these differences were statistically significant. CT examination at the last follow-up showed that all fractures were healed, all patients in the bone defect area ≤25% group achieved good reduction, and 3 patients in the bone defect area >25% group had step-offs on the glenoid surface. Postoperative shoulder adhesion occurred in 5 patients, which was improved after intensive abduction and external rotation exercise. Conclusions:Arthroscopic suture anchor fixation is effective for the bone defect area ≤25% bony Bankart lesions, offering advantages of minimal invasiveness and rapid recovery. For lesions involving more than the bone defect area 25% of the glenoid surface, enhanced fixation strength is recommended to prevent fracture fragment displacement.