The influence of proximal projection on the efficacy of minimally invasive osteotomy for mild to moderate hallux valgus
10.3760/cma.j.cn121113-20240519-00304
- VernacularTitle:截骨近端隆起对轻中度 外翻微创Chevron-Akin截骨术后疗效的影响
- Author:
Jieyuan ZHANG
1
;
Shaoling FU
1
;
Cheng WANG
1
;
Fan YANG
1
;
Jiazheng WANG
1
;
Chenglin WU
1
;
Zhongmin SHI
1
Author Information
1. 上海交通大学医学院附属第六人民医院骨科足踝外科,上海 200233
- Publication Type:Journal Article
- Keywords:
Hallux valgus;
Minimally invasive surgical procedures;
Osteotomy;
Treatment outcome;
Medial bony eminence
- From:
Chinese Journal of Orthopaedics
2025;45(3):172-179
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the clinical efficacy of minimally invasive Chevron-Akin osteotomy (MICA) in the treatment of mild to moderate hallux valgus without addressing the proximal projection.Methods:A retrospective analysis was conducted on 31 patients with unilateral mild to moderate hallux valgus who underwent third-generation MICA surgery at Shanghai Sixth People's Hospital from January 2019 to June 2020. Among these patients, 2 were male and 29 were female, with an average age of 41.13±7.8 years (range: 21-64 years). A total of 12 patients had mild hallux valgus, while 19 patients had moderate hallux valgus. The average body mass index (BMI) was 24.37±1.28 kg/m 2 (range: 22.06-26.13 kg/m 2). Preoperative and postoperative foot X-rays were taken at multiple time points, including 1 day, 1.5 months, 3 months, 12 months, and 24 months after surgery. These X-rays were used to assess the medial eminence width (MEW) of the first metatarsal head, the proximal medial projection width (PMRW) of the first metatarsal, the hallux valgus angle (HVA), the intermetatarsal angle (IMA), and the distal metatarsal articular angle (DMAA). Functional improvements and pain relief were evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score and the visual analogue scale (VAS). Results:All 31 patients completed an average follow-up period of 25.67±2.35 months (range: 24-31 months). The average operation time was 39.55±7.31 minutes (range: 32-46 minutes). The number of intraoperative fluoroscopy exposures averaged 16.23±2.38 times (range: 13-21 times). At the two-year follow-up, significant improvements were observed in all measured parameters when compared to preoperative values ( P<0.05). The HVA decreased from 35.18°±3.59° before surgery to 10.93°±0.90° after surgery. The IMA was reduced from 11.47°±0.85° to 6.94°±0.65°, and the DMAA decreased from 15.24°±1.13° to 4.31°±0.56°. The MEW decreased from 4.07±0.70 mm to 0.13±0.11 mm. The PMRW, which was measured at one day postoperatively and at the two-year follow-up, decreased from 3.44±0.66 mm to 0.19±0.11 mm. Functional assessments also showed significant improvements ( P<0.05). The AOFAS forefoot score increased from 57.42±3.93 before surgery to 89.52±3.46 at the two-year follow-up. Pain levels, as assessed by the VAS, decreased from 5.68±1.11 preoperatively to 0.77±0.50 postoperatively. At the two-year follow-up, 97% of patients reported excellent satisfaction with the surgical outcome. During the follow-up period, complications included mild numbness around the wound in two cases, metatarsophalangeal joint stiffness in one case, and hallux valgus recurrence in one case, accounting for 3% of the cohort. Conclusion:Third-generation MICA without addressing the proximal projection is an effective procedure for correcting mild to moderate hallux valgus. This technique significantly improves foot function, reduces pain, and leads to high levels of patient satisfaction.