The application value of the"triple-low"technique combined with the artificial intelligence iterative reconstruction in craniocervical CT angiography
10.3969/j.issn.1002-1671.2025.03.032
- VernacularTitle:"三低"技术联合人工智能迭代重建算法在头颈部CT血管成像中的应用价值
- Author:
Yanhao TONG
1
;
Xuqian CHEN
;
Min JI
;
Cheng YAN
Author Information
1. 复旦大学附属中山医院放射诊断科,上海 200032
- Publication Type:Journal Article
- Keywords:
computed tomography;
angiography;
artificial intelligence;
radiation dose
- From:
Journal of Practical Radiology
2025;41(3):501-505
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the application value of the"triple-low"(low radiation dose,low contrast medium and low con-trast flow rate)technique combined with the artificial intelligence iterative reconstruction(AIIR)in craniocervical computed tomo-graphy angiography(CTA).Methods Seventy patients undergoing head and neck CTA were prospectively enrolled and randomized into group A and group B,with 35 patients in each group.Group A was the"triple-low"technique group(80 kV,0.4 mL/kg,2.5 mL/s);group B was the control group(120 kV,0.7 mL/kg,5 mL/s).Group A images used AIIR and hybrid iterative reconstruction(HIR),and obtained group A1 and group A2;group B images used HIR.CT values,standard deviation(SD)values,signal-to-noise ratio(SNR),and contrast-to-noise ratio(CNR)at the level of the aortic arch,common carotid artery bifurcation,internal carotid artery segment C3 and middle cerebral artery segment M1 in the three groups of CTA images were measured and analyzed.The radiation dose and contrast medium were also compared.Two radiologists performed the double-blind evaluation of the image quality of differ-ent CTA segments in the three groups using a 5-point scale.Kappa analysis was used to analyze the compatibility of two people's scores.Results The radiation dose and contrast medium of group A were reduced by about 68.21%and 44.44%compared with those of group B,respectively.The differences were statistically significant(P<0.05).The SNR,CNR of group A1 were higher than those of group B and group A2,and the differences were statistically significant(P<0.05).The Kappa value of subjective score in group A1 was 0.688;the Kappa value of subjective score in group B was 0.499;the Kappa value of subjective score in group A2 was 0.571,which was in good agreement and statistically significant(P<0.05).Conclusion The"triple-low"technique combined with the AIIR in craniocervical CTA can significantly reduce the radi-ation dose and contrast medium.And its image quality is better than conventional scans which are reconstructed with HIR.