Application of a wearable visual field meter based on extended reality glasses in macular disease
10.3760/cma.j.cn115989-20250610-00196
- VernacularTitle:基于扩展现实的眼镜式可穿戴视野计在黄斑疾病视野功能评估中的应用
- Author:
Jing YUAN
1
;
Xingchang WANG
;
Xiquan SUN
;
Huiguang JIAO
;
Qian WANG
;
Yanxia TONG
;
Biyue TU
;
Xixi YAN
;
Zhen ZHAO
;
Xiaojie OU
;
Sawut ABDULLA
Author Information
1. 武汉大学人民医院眼科中心,武汉 430060
- Publication Type:Journal Article
- Keywords:
Macular disease;
Visual field;
Extended reality;
Humphrey visual field meter;
Mean light sensitivity
- From:
Chinese Journal of Experimental Ophthalmology
2025;43(11):1035-1040
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the application effect of a wearable visual field meter based on extended reality (XR) glasses for patients with macular disease.Methods:A self-controlled study was conducted.A total of 41 consecutive patients (41 eyes) with macular disease were recruited at Renmin Hospital of Wuhan University from October 2022 to October 2024.All patients underwent 10-2 center visual field test using a self-developed wearable visual field meter (XRVF), and the results were compared with those obtained using a traditional Humphrey field analyzer (HFA).The comparison parameters included mean retinal sensitivity (MS), false positive rate (FPR), false negative rate (FNR), and testing duration.A subject satisfaction questionnaire was administered.This study followed the Declaration of Helsinki.The study protocol was approved by the Medical Ethics Committee of Renmin Hospital of Wuhan University (No.WDRY2024-K263), and all subjects signed the informed consent form.Results:The retinal sensitivity of patients measured by HFA was (23.24±3.71)dB, which was higher than (22.01±3.45)dB by XRVF, showing a statistically significant difference ( t=4.924, P=0.036).The FPR measured by HFA and XRVF were (2.39±2.51)% and (2.59±3.29)%, respectively, and the FNR were (3.49±6.05)% and (3.74±5.38)%, respectively, showing no statistically significant difference ( t=-3.624, P=0.948; t=-1.241, P=0.519).The median test duration for HFA and XRVF was 6.15 (5.78, 6.65) and 5.98 (5.71, 6.69)minutes, respectively, without statistically significant difference ( Z=-1.987, P=0.953).92.6% of the subjects thought the device was comfortable, simple and practical. Conclusions:The XRVF has good consistency with the HFA, can effectively and reliably evaluate the visual field function of patients with macular disease, and is easily accepted by patients.