Experimental study on alternative method of local lymph node assay using bromodeoxyuridine with flow cytometry(LLNA:BrdU-FCM)for skin sensitization evaluation of cosmetics
- VernacularTitle:LLNA:Brdu-FCM替代方法用于化妆品皮肤致敏性评价
- Author:
Xiao-jun LYU
1
;
Ju ZHANG
1
;
Sen WU
1
;
Xiao-ling XU
1
;
Meng-ting SHI
1
;
Jin-jing XU
1
;
Wang-ping PAN
1
;
Jia-te SHEN
1
;
Kai-yong HE
1
Author Information
- Publication Type:Journal Article
- Keywords: sensitization; alternative method; LLNA:Brdu-FCM; stimulation index; cosmetics
- From: Chinese Pharmacological Bulletin 2025;41(4):793-799
- CountryChina
- Language:Chinese
- Abstract: Aim To establish and evaluate an alternative meth-od for detecting skin sensitization of cosmetics based on local lymph node assay using bromodeoxyuridine(BrdU)with flow cytometry(FCM).Methods(1)25%hexyl cinnamic alde-hyde(HCA)was chosen as a positive control with an acetone:olive oil(4∶1,V/V,AOO)mixture as a vehicle control for the experiment.The dorsal sides of both ears of mice were treated with test solutions on day 1,day 2,and day 3.Brdu solution was injected inter-peritoneally on day 5.On day 6,the bilateral ears and mandibular lymph nodes were excised,and the number of Brdu positive cells was measured by flow cytometry.The stim-ulation index(SI)was calculated to identify whether it was ≥3,in order to establish the method of LLNA:Brdu-FCM.(2)BrdU-FCM test was conducted using a blind method with the fif-teen reference substances listed in OECD TG429 whose skin sensitization potentials were known.The test substances were dissolved in AOO,N,N-dimethylformamide(DMF)or dimeth-yl sulfoxide(DMSO)at three different concentrations.Tests were performed the same as above.SI and EC2.7 were calculat-ed to evaluate whether the test substance was categorized as a skin sensitizer.The reliability and accuracy of the method were validated by comparing the classification of test substances with that in OECD TG429.Results The SI for 25%HCA was 3.9,showing positive in the skin sensitization test.It demonstrated that the LLNA:Brdu-FCM test method was properly implemen-ted.Nine test substances(2,4-dinitrochlorobenzene,4-pheny-lenediamine,cobalt chloride,2-mercaptobenzothiazole,hexyl-cinnamaldehyde,eugenol,phenyl benzoate,cinnamic alcohol,imidazolidinyl urea)were positive,and six test substances(methyl methacrylate,chlorobenzene,isopropanol,lactic acid,methyl salicylate,salicylic acid)were negative.The method was evaluated with sensitivity of 90%,specificity of 100%,positive prediction rate of 100%,negative prediction rate of 83%,false positive rate of 0%,false negative rate of 17%and accuracy of 93%.The LLNA:BrdU-FCM assay could correctly categorize the test substances that were skin sensitizers or non-sensitizers.Conclusion The LLNA:BrdU-FCM assay appears to be a relia-ble predictor of skin sensitization protential of chemicals,and it is expected to an alternative method for identifying skin sensitization as a supplementary in safety evaluation of cosmetic ingredient.
